100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Florida Building Code – Building 2025 Practice Test with 250 Recently Tested Questions and Correct Answers / FL Building Code Exam Prep Qs and Correct As

Rating
-
Sold
-
Pages
62
Grade
A+
Uploaded on
11-10-2025
Written in
2025/2026

Florida Building Code – Building 2025 Practice Test with 250 Recently Tested Questions and Correct Answers / FL Building Code Exam Prep Qs and Correct As

Institution
Florida Building Code – Building
Course
Florida Building Code – Building











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Florida Building Code – Building
Course
Florida Building Code – Building

Document information

Uploaded on
October 11, 2025
Number of pages
62
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Florida Building Code – Building 2025 Practice Test with
250 Recently Tested Questions and Correct Answers / FL
Building Code 2025-2026 Exam Prep Qs and Correct As

According to the Florida Building Code, the distance in feet measured from the
building face to the closest interior lot line, to an alley or public way, to the
centerline of a street, or to an imaginary line between two buildings on the same
property is defined as:
A. Property line
B. Building line
C. Fire separation distance
D. Street line - ANSWER-C. Fire separation distance


According to the Florida Building Code, a car wash should be classified under
which Occupancy Group?
A. Group A
B. Group B
C. Group E
D. Group F - ANSWER-B. Group B


Construction or work for which a permit is required shall be subject to inspection
by the:
A. Building official
B. Owner
C. Architect
D. Engineer - ANSWER-A. Building Official




pg. 1

,The ________ shall determine the timing and sequencing of when inspections
occur and what elements are inspected at each inspection:
A. Owner
B. Architect
C. Contractor
D. Building Official - ANSWER-D. Building Official


The building foundation inspection is performed:
A. After trenches are excavated and forms erected and shall at a minimum include
the stem-wall and monolithic slab-on-grade.
B. After trenches are excavated and forms erected and shall at a minimum include
the stem-wall, monolithic slab-on-grade and piling/pile caps.
C. After trenches are excavated and forms erected and shall at a minimum include
the stem-wall, monolithic slab-on-grade, piling/pile caps, footers/grade beams
D. After trenches are excavated and forms erected and shall at a minimum include
the stem-wall, monolithic slab-on-grade, piling/pile caps, footers/grade beams, and
soil termite treatment - ANSWER-C. After trenches are excavated and forms
erected and shall at a minimum include the stem-wall monolithic slab-on-grade,
piling/pile caps, footers/grade beams


According to Florida Building Code, what are the minimum inspections required
for a building (exclusive of electrical, plumbing, mechanical and gas) made by the
Building Official)?
A. Excavation, framing, final and swimming pool
B. Foundation, framing, sheathing, roofing and final
C. Foundation, forms, insulation and final
D. Structural, foundation, framing and dry-in inspection - ANSWER-B.
Foundation, framing, sheathing, roofing and final




pg. 2

,For a typical building under construction, which building inspection usually
precedes the final inspection on the building?
A. Sheathing inspection
B. Framing inspection
C. Roofing inspection
D. Drywall inspection - ANSWER-C. Roofing inspection


According to the Florida Building Code, what is the proper order of the electrical
inspection?
A. Underground inspection, rough-in inspection, final inspection
B. Rough-in inspection, underground inspection, final inspection
C. Underground inspection, final inspection, rough-in inspection
D. Rough-in inspection, final inspection, underground inspection - ANSWER-A.
Underground inspection, rough-in inspection, final inspection


According to Florida Building Code, to prevent the entry of birds, squirrels,
rodents, etc., openings into attic spaces of habitable buildings shall be covered with
screening, hardware cloth or equivalent with openings not exceeding:
A. 1/16"
B. 1/8"
C. 1/4"
D. 1/2" - ANSWER-C. 1/4"
Page 413


According to the Florida Building Code, the minimum corridor width used as a
means of egress for Group 1 - 2, Unrestrained occupancies, requiring the
movement of beds, shall be:
A. 44"

pg. 3

, B. 56"
C. 72"
D. 96" - ANSWER-D. 96"
Page 395


Which of the following is NOT true?
A. A Certificate of Completion allows the tenant to begin occupying spaces in a
shell building
B. A temporary Certificate of Occupancy allows tenants to occupy safe portions of
an incomplete building
C. New buildings may not be occupied until the Building Official issues a
Certificate of Occupancy
D. A Certificate of Completion allows utilities to be hooked up - ANSWER-A. A
Certificate of Completion allows the tenant to begin occupying spaces in a shell
building


What building material is installed to resist the free passage of flame to other areas
of the building through concealed spaces?
A. Fire wall
B. Fire partition
C. Fire damper
D. Fire blocking - ANSWER-D. Fire blocking


A masonry unit in which the net concrete cross-sectional area parallel to the
bearing surface is 75% or more is classified as a:
A. Semi-solid masonry unit
B. Solid masonry unit
C. Hollow core masonry unit

pg. 4

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
muriithikelvin Chamberlain College Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
1412
Member since
2 year
Number of followers
552
Documents
2842
Last sold
2 days ago
GOLD-RATED TOP SELLER ON STUVIA – YOUR TRUSTED HUB FOR EXCEPTIONAL STUDY RESOURCES! ACHIEVE MORE WITH EXPERTLY CRAFTED MATERIALS THAT GUARANTEE RESULTS!

Feeling overwhelmed by exams? We’re here to help. Our study materials help you focus, build confidence, and walk into your exams ready. Compiled using real past exams, these resources give you valuable insight into the kinds of questions to expect and how to approach them — helping you maximize your scores and study smarter. Why Choose Us? Gold-rated seller. 1,250+ happy students. Trusted resources for healthcare and certification success. Friendly support whenever you need it.

Read more Read less
3.9

278 reviews

5
139
4
55
3
41
2
14
1
29

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions