FIRE ALARM LEVEL 1 EXAM NEWEST 2025/2026 ACTUAL EXAM
WITH COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS
(100% VERIFIED ANSWERS) |ALREADY GRADED A+| ||PROFESSOR
VERIFIED||
The fire alarm service provider shall report to the AHJ any fire
alarm system that is out of service for more than___________.
A) 1 hour
B) 5 hours
C) 8 hours
D) 24 hours - ANSWER-C) NFPA 72 Index ~> impairments 10.21
PLFA cables shall be permitted to be in stall together with class
one, NPLFA a comma and medium power network powered
broadband communications circuit where,
_____________________
A) the cables are separated by a barrier
B) the cables are labeled with at least 600V
C) the cables are for fire alarms system use only
D) none of the above - ANSWER-A) NEC Index~> fire alarm
systems ~> power limited circuits~> conductors 760.136(B)
,2|Page
Which Characteristic it's true about a parallel circuit?
A) the sum of the voltage across each branch is equal to the total
voltage.
B) The total resistance of the circuit is the sum of the individual
resistors of the circuit.
C) the sum of the currents in each branch is equal to the total
circuit current.
D) none of the above - ANSWER-D) A Parralel circuit has several
branches
The total current of the circuit splits through each branch. Adding
the currents in each branch will results in the total current flow of
the circuit.
A grounding electrode shall not be less than:
A) 4 feet
B) 6 feet
C) 8 feet
D) 10 feet - ANSWER-C) NFPA 70 250.52
,3|Page
An initiating device which is destroyed as a result of its operation
is what type?
A) nonrestorable
B) spot-type
C) line type
D) Heat Detector - ANSWER-A)
Which of the following requirements is true?
A) Each floor of the building shall be zoned it separately
B) All unoccupied area shall be zoned separately
C) nine type in spot type heat detectors Shall be zoned separately
D) all of the above are true - ANSWER-D)
Which of the following is acceptable substitution for FPLR?
A) FPL
B) FPLP
C) CMP
D Both b & C - ANSWER-D)
, 4|Page
When installing heat detectors on a peak ceiling, a row of
detectors shall be located:
A) within 3 feet of the low side
B) on the side wall of the low side
C) within 1/2 the listed spacing of the peak
D) within 3 feet of the peak - ANSWER-D)
how shall sprinkler waterflow devices be tested?
A) a sprinkler head shall be activated
B) water shall be flowed from the inspector's test valve
C) short across the auxiliary "test" terminals of the switch
D) start the fire pump to test the water - ANSWER-B)
When running fire alarm wiring, which of the following are
acceptable?
A) attaching the wiring to existing conduit
B) attaching the wiring to the sprinkler piping.
C) attaching the wiring to the building structure.