100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Test 2 Objective Assessment Complete frequently TESTED Exam Questions with Definitive Correct Answers A+ Graded!!100% Guaranteed Pass!!<<Latest Version>>

Rating
-
Sold
-
Pages
39
Grade
A+
Uploaded on
20-09-2025
Written in
2025/2026

Test 2 Objective Assessment Complete frequently TESTED Exam Questions with Definitive Correct Answers A+ Graded!!100% Guaranteed Pass!!&lt;&lt;Latest Version&gt;&gt; Calculate the minimum size of the branch circuit conductors to source a motor given the following conditions: Operating Voltage: 480 volts. Electric Power: Three Phase - Motor Horsepower: 40 HP - Nameplate Rating: 50 amperes - Duty-Cycle Service: 15 minute, Intermittent duty 1. 12 AWG. 2. 6 AWG. 3. 4 AWG. 4. 3 AWG. - ANSWER 2. 6 AWG According to the National Electrical Code, what would be the calculated minimum trade size equipment grounding conductor required to protect one 5 HP, 208 V, 3- phase motor? Consider all the exceptions for rating or setting for individual motor circuits, and the use of an instantaneous trip breaker. 1. 2 AWG 2. 3 AWG 3. 4 AWG 4. 6 AWG - ANSWER 4. 6 AWG A 15-minute rated, 115 V, 2 HP, 3 phase squirrel-cage motor is to be used for intermittent duty. The minimum allowable ampacity of the branch-circuit conductors serving the motor is 1. 11.6 amps 2. 13.6 amps 3. 16.0 amps 4. 20.4 amps - ANSWER 1. 11.6 amps Given. A circuit load draws a total of 48 amperes, the resistive load on the circuit is 5 Ohms, determine source voltage for this circuit. 1. 120 volts 2. 240 volts 3. 277 volts 4. 480 volts - ANSWER 2. 240 volts Using the optional method described in Article 220 of the NEC, what is the smallest feeder that can supply a multi-family building, given it has 60 units, with a 4,000 watt dryer in each unit? 1. 50 kW 2. 75 kW 3. 277 KW 4. 300 kW - ANSWER 2. 75 kw The minimum allowable radius of the inner edge of a bend in mineral insulated metal-sheathed cable is 1. 2-1/2 in. for a 1/2-in. cable 2. 6 in. for a 1-in. cable. 3. 7 in. for a 1-in. cable : 4. 7 in. for a 1/2-in. cable. - ANSWER 1. 2-1/2 in. For a 1/2 - in cable A controller (contactor) has been installed to control an automatically started one horsepower motor with a marked service factor of 1.15. The motor nameplate fullload current rating is 8.8 amperes. What is the maximum size overload device that may be installed in this controller? 1. 10.1 amperes 2. 11.0 amperes 3. 11.8 amperes 4. 12.3 amperes - ANSWER 2. 11.0 amperes What would be the minimum required branch circuit for a combined equipment load of the following? - One, 7,000 watt range top - One, 8,000 watt wall-mounted oven 1. 8 kW 2. 15 kW 3. 12 kW 4. 9.2 kW - ANSWER 4. 9.2 kw Given an office building plan that consists of 25,000 sq-ft, with no receptacles displayed on the plan. Calculate the demand load of the receptacles. 1. 22.5 kW 2. 23.25 kW 3. 25.0 kW 4. 28.5 kW - ANSWER 3. 25.0 kw A fixed storage-type water heater that has a capacity of 120 gal or less shall be considered a continuous load for the purposes of sizing branch circuits. Therefore, if the heater has an element with a nameplate. rating of 6kW at 240-vac singlephase, what would be the minimum fuse or breaker size to protect this circuit? 1. 40 2. 35 3. 30 4. 20. - ANSWER 2. 35

Show more Read less
Institution
ATT 2
Course
ATT 2











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
ATT 2
Course
ATT 2

Document information

Uploaded on
September 20, 2025
Number of pages
39
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Test 2 Objective Assessment
Complete frequently TESTED Exam
Questions with Definitive Correct
Answers A+ Graded!!100%
Guaranteed Pass!!<<Latest
Version>>
Calculate the minimum size of the branch circuit conductors to source a motor
given the following

conditions: Operating Voltage: 480 volts.

Electric Power: Three Phase

- Motor Horsepower: 40 HP - Nameplate Rating: 50 amperes - Duty-Cycle
Service: 15 minute, Intermittent duty

1. 12 AWG.

2. 6 AWG.

3. 4 AWG.

4. 3 AWG. - ANSWER ✓ 2. 6 AWG

According to the National Electrical Code, what would be the calculated minimum
trade size equipment grounding conductor required to protect one 5 HP, 208 V, 3-
phase motor? Consider all the exceptions for rating or setting for individual motor
circuits, and the use of an instantaneous trip breaker.

1. 2 AWG

2. 3 AWG

3. 4 AWG

,4. 6 AWG - ANSWER ✓ 4. 6 AWG

A 15-minute rated, 115 V, 2 HP, 3 phase squirrel-cage motor is to be used for
intermittent duty. The

minimum allowable ampacity of the branch-circuit conductors serving the motor is

1. 11.6 amps

2. 13.6 amps

3. 16.0 amps

4. 20.4 amps - ANSWER ✓ 1. 11.6 amps

Given. A circuit load draws a total of 48 amperes, the resistive load on the circuit
is 5 Ohms, determine

source voltage for this circuit.

1. 120 volts

2. 240 volts

3. 277 volts

4. 480 volts - ANSWER ✓ 2. 240 volts

Using the optional method described in Article 220 of the NEC, what is the
smallest feeder that can supply a multi-family building, given it has 60 units, with
a 4,000 watt dryer in each unit?

1. 50 kW

2. 75 kW

3. 277 KW

,4. 300 kW - ANSWER ✓ 2. 75 kw

The minimum allowable radius of the inner edge of a bend in mineral insulated
metal-sheathed cable is

1. 2-1/2 in. for a 1/2-in. cable

2. 6 in. for a 1-in. cable.

3. 7 in. for a 1-in. cable :

4. 7 in. for a 1/2-in. cable. - ANSWER ✓ 1. 2-1/2 in. For a 1/2 - in cable

A controller (contactor) has been installed to control an automatically started one
horsepower motor with a marked service factor of 1.15. The motor nameplate full-
load current rating is 8.8 amperes. What is the maximum size overload device that
may be installed in this controller?

1. 10.1 amperes

2. 11.0 amperes

3. 11.8 amperes

4. 12.3 amperes - ANSWER ✓ 2. 11.0 amperes

What would be the minimum required branch circuit for a combined equipment
load of the following?

- One, 7,000 watt range top - One, 8,000 watt wall-mounted oven

1. 8 kW

2. 15 kW

3. 12 kW

4. 9.2 kW - ANSWER ✓ 4. 9.2 kw

, Given an office building plan that consists of 25,000 sq-ft, with no receptacles
displayed on the plan.

Calculate the demand load of the receptacles.

1. 22.5 kW

2. 23.25 kW

3. 25.0 kW

4. 28.5 kW - ANSWER ✓ 3. 25.0 kw

A fixed storage-type water heater that has a capacity of 120 gal or less shall be
considered a continuous load for the purposes of sizing branch circuits. Therefore,
if the heater has an element with a nameplate. rating of 6kW at 240-vac single-
phase, what would be the minimum fuse or breaker size to protect this circuit?

1. 40

2. 35

3. 30

4. 20. - ANSWER ✓ 2. 35

What is the secondary current of a single phase, step-up transformer if the primary
voltage is 120 volts, the secondary voltage is 600 volts, and the primary current is
10 amperes? (Assume no transformer
impedance)

1. 2 amperes

2. 5 amperes

3. 10 amperes

4. 50 amperes - ANSWER ✓ 1. 2 amperes

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SmartscoreAaron Chicago State University
View profile
Follow You need to be logged in order to follow users or courses
Sold
36
Member since
1 year
Number of followers
3
Documents
3023
Last sold
6 days ago
SMARTSCORES LIBRARY

Get top-tier academic support for Psychology, Nursing, Business, Engineering, HRM, Math, and more. Our team of professional tutors delivers high-quality homework, quiz, and exam assistance—ensuring scholarly excellence and grade-boosting results. Trust our collaborative expertise to help you succeed in any course at U.S.A Institutions.

3.8

4 reviews

5
2
4
1
3
0
2
0
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions