A bifocal lens in which the power regularly modifications from the important location of the lens
to the outer edge is called - ANS-An aspheric lens
A button is - ANS-A contact lens clean
A appropriate example of a bifocal touch lens which could rotate without imaginative and
prescient impairment is - ANS-Aspheric
A non wetting gas permeable lens may additionally reason?
Hazy, filmy vision, Lens awareness, and Dryness or grittiness - ANS-All the above
A normal tear spoil-up time is: - ANS-10-12 seconds
A affected person is diagnostically healthy with the gasoline permeable lens With the following
parameters: 42.50-three.00 nine.5. If you want to flatten the lens to cornea courting, which of
the following lenses might you order?
A. Forty two.00-2.00 10.0
B.Forty two.50-three.00 nine.0
C.43.Zero-3.50 nine.5
D.Forty three.50 -three.50 9.Zero - ANS-B. 42.00 -3.00 9.0
A affected person with a high degree of with the guideline astigmatism equipped with a round
has permeable lenses will show touch: - ANS-On the horizontal meridian
A patient's ok analyzing are. 43.50 @ 180/41.50 @ ninety.A round GP lens can be predicted to:
- ANS-Displays down and in, or down and out with every blInk
A pre-presbyopic myopic affected person who's nonetheless capable of examine with single
vision glasses may discover that - ANS-They are unable to see best print when they may be fit
with touch lenses
A prism ballast GP lens requires how a great deal prism for proper orientation? - ANS-0.Seventy
five to 1.50 D
A inflexible touch lens measures +15.00D BVP. The FVP will degree - ANS-A lesser dioptric
studying
A inflexible lens corrects astigmatism by way of - ANS-Forming a new spherical refracting
surface in the front of the cornea
,A inflexible Lens showing a band shaped location of contact on the flattest meridian is a sign of
a lens fit on a: - ANS-Astigmatic cornea
A rigid lens showing apical pooling is a sign of
a. Steep match
b. An alignment in shape
c. A flat healthy
d. An astigmatic suit - ANS-steep fit
A rigid lens showing apical contact is an indication of: - ANS-flat suit
A inflexible lens showing critical vaulting is indicative of: - ANS-Apical clearance match
A rigid lens showing immoderate apical pooling is an indication: - ANS-a. Steep in shape
A rigid lens shows two curves on the convex surface one measured with radiuscope. On the
lensometer, it shows one strength. What sort of lens is this? - ANS-Warped
A soft touch lens that is too free might also display all of the following except
1. Edge stand off
2. Limbal compression
3.Excessive Lens motion
four. Distorted retinoscopy immediately after blinking - ANS-Limbal compression
A tender lens has an facet lift when located on a cornea. How can this be corrected? -
ANS-Steepen the bottom curve
A gentle lens ought to by no means be match with apical clearance why - ANS-Because it'd
bring about a decent in shape
A technician can carry out a preliminary evaluation of tender touch lens movement by means of:
Observing the motion of the lens part in relation to position of a conjunctival vessel, Having the
affected person look up and blink, Observing movement and lens lag in upward and lateral gaze
with a penlight - ANS-All of the above
A toric gentle lens will correct:
A. Residual astigmatism
B. Moderate astigmatism (more than 2.00D)
C. Low astigmatism (0.75 to two.00D)
D. All of the above - ANS-D. All of the above
, A tender toric lens will accurate residual and lenticular astigmatism, as well as low to slight
quantities of corneal astigmatism. Custom made tender toric lenses have also been effective in
correcting better degrees of astigmatism with great achievement
A warped lens will show___________ base curve(s) at the radiuscope and a ________
electricity on the lensometer.
A. One/spherical
b. /sphero-cylindrical
c. One/sphero-cylindrical
d. Two/spherical - ANS-d. Two/spherical
A whitish haze within the peripheral corneal stroma which does now not stain and is frequently
seen inside the elderly is known as? - ANS-Arcus senilus
According the Federal contacts regulation contacts RX must be written? 1 12 months, 2 12
months, practioner discretion and so forth. - ANS-1 Year
After Penetrating Keroplasty what corneal layer does no longer regenerate? - ANS-Bowmans
Layer
Against the rule of thumb astigmatism - ANS-astigmatic "bow-tie" sample is aligned horizontally
All of the subsequent will permit the practitioner to verify the overall fuel permeable lens
diameter except
A. Slot gauge
B.Shadow graph
C.Measuring magnifier
D. Radius scope - ANS-Radiuscope
Amy's +8.50D spectacles take a seat 12 mm from the cornea. The electricity of a smooth touch
lens for Amy, well vertexted, would be? - ANS-+9.50D
An aphakic lens affected person wears glasses, with contacts he'll see now greater? -
ANS-minifed
An inability to carry all of the keratometer mires into awareness on the same time may also
suggest - ANS-Irregular astigmatism
An device that permits simultaneous verification of lens diameter, optic region with an peripheral
curve with is: - ANS-Measuring magnifier
An inverted or flat becoming Lens will frequently display - ANS-Edge carry or standoff