Questions and Answers 100%
Guaranteed Success | Already Rated A+
What is the minimum height of a landing door? - 🧠ANSWER ✔✔6' 6"
84.1 17.07 (2)
What is the minimum size of a vent in a hoistway? - 🧠ANSWER ✔✔3 1/2%
of the area of the hoistway or 3 square. Whichever is greater.
80 17.03 (3)
,What is the minimum length of a babitted socket? - 🧠ANSWER ✔✔The
length of the socket shall be not less than 4.75 times the nominal diameter
of the rope.
113 17.26 (16)(a)
What is the maximum numbers of elevators in one bank? - 🧠ANSWER
✔✔No more than 4 elevators shall be installed in the same hoistway.
76 17.01 (4)
What is the maximum size of a resident elevator? - 🧠ANSWER ✔✔12
square feet
161 23.01
What is the minimum size hoisting rope allowed? - 🧠ANSWER ✔✔1/2 inch
diameter
111 17.26 (4)
, What is the maximum speed for an instantaneous type safety? - 🧠ANSWER
✔✔125 feet per minute.
101 17.16 (4)
What is the size of the side emergency exit panel? - 🧠ANSWER ✔✔At least
16" in width
5' in height
17.14 (4)(d)
What is the maximum speed of an elevator in Massachusetts? - 🧠ANSWER
✔✔1500 FPM - Traction
500 FPM - Hydraulic
104 17.17 (1),(3)
What is the maximum inspection speed? - 🧠ANSWER ✔✔150 FPM