California UST Service Technician part 1question with
answers
July 1 2005, service techs shall possess or work under someone who has a current
certification indicating he or she has passed the ? - -California UST service technician
exam
-ICC cert must be renewed every? - -24 months
-Service techs must posses or be employed by a person who has the appropriate
contractors license unless? - -The individual has a Tank testing licens
-Service tech is defined by any individual who? - -Test UST monitoring equipment
Trouble shoots UST systems
Installs UST monitoring equipment
-If the manufacturer training no longer exist , the local angency may? - -Approve
comparable alternat training .
-UST includes? - -Tank and connected piping
-What is considered and UST - -petroleum storage tank
-What UST system meets the requirements for secondary containment? - -Doubled
wall tanks
-According to title 23; the following piping components if installed after July 1 1987
must have secondary containment - -Pressured product piping
-Considered "pipe" on tanks installed after July 1 2003 - -Pressured product piping
and below ground vapor recovery
-Under dispenser containment (UDC) was required for all UST systems by - -
December 31 2003
-System for exchanging gas vapors in a storage tank and product in a fuel delivery
truck - -Stage 1 vapor recovery
-An approved method for non visual monitoring for existing UST systems. - -
Statistical Inventory Reconciliation (SIR)
-ATG must be capable for detecting a release of ? - -.2 gallons per hour
-Manual inventory reconciliation. - -No longer an approved method for non visual
monitoring on existing UST systems
-Automatic line leak detectors installed on underground piping with secondary
containment shall be capable of tetecting a leak of ? - -3 gallons per hour at 10 psi
answers
July 1 2005, service techs shall possess or work under someone who has a current
certification indicating he or she has passed the ? - -California UST service technician
exam
-ICC cert must be renewed every? - -24 months
-Service techs must posses or be employed by a person who has the appropriate
contractors license unless? - -The individual has a Tank testing licens
-Service tech is defined by any individual who? - -Test UST monitoring equipment
Trouble shoots UST systems
Installs UST monitoring equipment
-If the manufacturer training no longer exist , the local angency may? - -Approve
comparable alternat training .
-UST includes? - -Tank and connected piping
-What is considered and UST - -petroleum storage tank
-What UST system meets the requirements for secondary containment? - -Doubled
wall tanks
-According to title 23; the following piping components if installed after July 1 1987
must have secondary containment - -Pressured product piping
-Considered "pipe" on tanks installed after July 1 2003 - -Pressured product piping
and below ground vapor recovery
-Under dispenser containment (UDC) was required for all UST systems by - -
December 31 2003
-System for exchanging gas vapors in a storage tank and product in a fuel delivery
truck - -Stage 1 vapor recovery
-An approved method for non visual monitoring for existing UST systems. - -
Statistical Inventory Reconciliation (SIR)
-ATG must be capable for detecting a release of ? - -.2 gallons per hour
-Manual inventory reconciliation. - -No longer an approved method for non visual
monitoring on existing UST systems
-Automatic line leak detectors installed on underground piping with secondary
containment shall be capable of tetecting a leak of ? - -3 gallons per hour at 10 psi