BACKFLOW TEST PREP 1
QUESTIONS AND ANSWERS



Design, material, and operational standards for DCVA & RPBA are found in the -
Correct Answers -AWWA standards

Approved backflow prevention assemblies must be designed to be - Correct Answers -
disassembled and repaired in line for all sizes

Check valves must be internally loaded and must be drip-tight - Correct Answers -in the
direction of flow with a minimum of 1 psi differential

The maximum allowable pressure loss through a 3/4" DCVA is - Correct Answers -10
psi

The maximum allowable pressure loss through a 3/4" RPBA is - Correct Answers -20
psi

The markings required to be on all approved backflow prevention assemblies include -
Correct Answers -make, model, direction of flow, & MWP

As part of an inspection of the assembly a BAT must determine - Correct Answers -if
the assembly is currently listed and approved for the orientation that it is installed

A cross-connection is defined as any actual or potential physical connection between a
public potable water system or the consumer's potable water system and any source of
non-potable liquid, solid, or gas that could the potable water supply by backflow -
Correct Answers -contaminate

The undesirable reversal of flow of water or other substances through a cross-
connection into the public water system or consumer's potable water system is - Correct
Answers -backflow

Backsiphonage backflow is defined as backflow due to a reduction in system pressure.
What else must be present for - Correct Answers -an opening to atmosphere

Which of the following may cause backpressure backflow? - Correct Answers -any of
the above (elevated piping, pumps, hot water tanks)

, A direct cross-connection is subject to - Correct Answers -both backsiphonage and
backpressure
A column of water exerts pressure at the bottom of the column due to the - Correct
Answers -weight of the water in the column

If the gauge pressure in a water pipe is negative, this means that exists - Correct
Answers -a vacuum

The BAT must complete a test report form acceptable to the local water purveyor -
Correct Answers -after every test of an approved backflow prevention assembly or
inspection of an approved air gap

The results of a test of an approved backflow prevention assembly must be reported to
the water purveyor on a form acceptable to - Correct Answers -the purveyor

An approved air gap is a physical separation between - Correct Answers -the end of the
potable water supply pipe and the overflow rim of the receiving vessel, a distance of at
least 2 times supply pipe diameter and never less than 1"

An approved air gap is acceptable as backflow protection for - Correct Answers -
Backpressure as well as Backsiphonage and both High and Low Health Hazard

An approved backflow prevention assembly is an RPBA, RPDA, DCVA, DCDA, PVBA,
or SVBA of make, model and size that is - Correct Answers -approved by the
Washington State DOH, ODW

Newly installed backflow assemblies have a initial test primarily due to: high rate of
failure at the time of the - Correct Answers -debris from within the supply piping

If a customer requires continuous water service it is recommended that - Correct
Answers -a parallel set of backflow assemblies appropriate for the degree of hazard be
installed

The shut off valves used on approved Backflow Prevention assemblies must always be
- Correct Answers -resilient seated

An approved backflow prevention assembly must be installed in such a manner that -
Correct Answers -it will not become flooded and with adequate space around the
assembly to facilitate testing and maintenance

An RPBA must not be installed where - Correct Answers -all of the above (water spilt
from the assembly will be objectionable, the assembly will become flooded, the
assembly is more than 60 inches above the floor or ground)

Written for

Institution
BACKFLOW
Course
BACKFLOW

Document information

Uploaded on
July 21, 2025
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$12.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Thumbnail
Package deal
BACKFLOW BUNDLED EXAM
-
42 2025
$ 514.08 More info

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Gordones22 Yala university
View profile
Follow You need to be logged in order to follow users or courses
Sold
498
Member since
3 year
Number of followers
351
Documents
9499
Last sold
4 weeks ago

4.1

108 reviews

5
63
4
17
3
13
2
4
1
11

Trending documents

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions