_______ is a benefit or right for which the parties to a contract must bargain.
A. Consideration
B. Act of God
C. lis pendens
D. Contractual Indemnification - Correct Answers-Consideration
"Double-tapping" is ____________.
A. the term for connecting two wires in a wire nut before connecting them to a breaker or fuse
B. an approved method for extending a service panel's capacity
C. the term for attaching two wires to a single fuse or breaker terminal
D. the certified approach for installing a sub-panel
E. not acceptable unless the same number of taps occur on one bus as the other - Correct
Answers-The term for attaching two wires to a single fuse or breaker terminal
34. All of the following are common wood siding types except
A. Flemish bond.
B. Bevel
C. Board and batten
D. Tongue and groove - Correct Answers-A. Flemish bond (is a brick pattern)
A "Channel and drop" is a type of __________.
A, technique for measuring a homesite
B. wood siding
C. method for digging
,D. irrigation ditches and laying in pipe
E. technique for installing windows - Correct Answers-wood siding
A "cross connection" is a physical connection between two electrical circuits. - Correct
Answers-False
A "system" carries out one or more functions in a structure and is composed of at least two
interacting or interdependent components. - Correct Answers-True
A "system" does not carry out one or more function in a structure and is composed of at least
two interacting or interdependent components. - Correct Answers-False
A "technically exhaustive" inspection uses measurements, tests, calculations and instruments to
gather information on the structure under inspection. - Correct Answers-True
A 10-AWG copper wire corresponds to ____-amp fuse size.
A. 15
B. 30
C. 40
D. 20 - Correct Answers-30
A 12-AWG copper wire corresponds to ____-amp fuse size.
A. 20
B. 30
C. 15
D. 40 - Correct Answers-20
A 14-2 Romex wire should be used with _____-amp breakers.
A. 20
B. 10
C. 15
, D. 40
E. 30 - Correct Answers-15
A 14-AWG copper wire corresponds to ____-amp fuse size.
A. 15
B. 30
C. 40
D. 20 - Correct Answers-15
A 2,000-watt, 240-volt electric heater would draw ________ amps of current.
A. 10
B. 7
C. 3.72
D. 8.33
E. 6.45 - Correct Answers-8.33
A 3-phase electrical system has ___ poles.
A. two
B. four
C. six
D. three - Correct Answers-Three
A 3-pole main disconnect might indicate ___________.
A. fused neutral conductor
B. allowance for future
C. upgrades