100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

S12 Sprinkler FDNY Exam (122 questions) with accurate detailed solutions

Rating
-
Sold
-
Pages
18
Grade
A+
Uploaded on
29-06-2025
Written in
2024/2025

S12 Sprinkler FDNY Exam (122 questions) with accurate detailed solutions

Institution
S12
Course
S12










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
S12
Course
S12

Document information

Uploaded on
June 29, 2025
Number of pages
18
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

S12 Spr inkler FDNY Exam w ith |! |! |! |! |!




accur ate detailed solutions |! |!




What is a sprinkler system? - Correct answer ✔A fire extinguishing system,
|! |! |! |! |! |! |! |! |! |! |! |!




other than a mist fire extinguishing system that utilizes water as the
|! |! |! |! |! |! |! |! |! |! |! |!




extinguishing agent |!




How long must a detailed record be kept? - Correct answer ✔Minimum 3
|! |! |! |! |! |! |! |! |! |! |! |! |!




years



How often are sprinklers subject to a hydrostatic pressure test? - Correct
|! |! |! |! |! |! |! |! |! |! |! |!




answer ✔At least once every 5 years
|! |! |! |! |! |!




Who's responsible for maintaining the sprinkler system? - Correct answer
|! |! |! |! |! |! |! |! |! |!




✔Owner



Under what conditions should the FD be notified if a sprinkler system is
|! |! |! |! |! |! |! |! |! |! |! |! |!




OOS? - Correct answer ✔- sprinkler out of service on more than 1 floor of a
|! |! |! |! |! |! |! |! |! |! |! |! |! |! |! |!




building

- work cannot be completed and system restored within 8 hours
|! |! |! |! |! |! |! |! |! |!




-one or more fire protection services are out of service at the same time
|! |! |! |! |! |! |! |! |! |! |! |! |!

,If no impairment is found: - Correct answer ✔Green tag placed on main
|! |! |! |! |! |! |! |! |! |! |! |! |!




control valve |!




If a system is fully out of service what color disc should be placed on the FD
|! |! |! |! |! |! |! |! |! |! |! |! |! |! |! |! |!




connection? - Correct answer ✔White |! |! |! |!




If a system is partially out of service what color disc should be placed on the
|! |! |! |! |! |! |! |! |! |! |! |! |! |! |! |!




FD connection? - Correct answer ✔Blue
|! |! |! |! |!




What color tag should be placed on the main control valve if a system if fully
|! |! |! |! |! |! |! |! |! |! |! |! |! |! |! |!




or partially out of service? - Correct answer ✔Red
|! |! |! |! |! |! |! |!




What should the red tag on a main control valve indicate? - Correct answer
|! |! |! |! |! |! |! |! |! |! |! |! |! |!




✔Sprinkler company name, date of removal from service, and anticipated
|! |! |! |! |! |! |! |! |! |!




return to service date |! |! |!




Before authorizing the placing of the fire protection out of service the
|! |! |! |! |! |! |! |! |! |! |! |!




impairment coordinator shall: - Correct answer ✔• Notify the Certificate of
|! |! |! |! |! |! |! |! |! |! |!




Fitness holder responsible for supervising the maintenance of the standpipe
|! |! |! |! |! |! |! |! |! |!




system, sprinkler system or fire alarm system.
|! |! |! |! |! |!




• Determine the extent and expected duration of the out-of-service condition.
|! |! |! |! |! |! |! |! |! |!




• Inspect the areas or buildings involved and assess the increased risks. Make
|! |! |! |! |! |! |! |! |! |! |! |! |!




appropriate recommendations to the owner. |! |! |! |!




• Notify the Fire Department in accordance with FC 901.7.5, if required.
|! |! |! |! |! |! |! |! |! |! |!




• Notify the responsible person designated by the owner to issue hot work
|! |! |! |! |! |! |! |! |! |! |! |! |!




authorizations in accordance with FC Chapter 26. |! |! |! |! |! |!

, • Notify the central station and insurance carrier.
|! |! |! |! |! |! |!




• Notify the occupants in the affected areas if the duration of time the
|! |! |! |! |! |! |! |! |! |! |! |! |! |!




sprinkler system or fire alarm system will be out of service is estimated to be
|! |! |! |! |! |! |! |! |! |! |! |! |! |! |!




more than 30 minutes.
|! |! |!




• Place a tag at each fire department connection, standpipe and sprinkler
|! |! |! |! |! |! |! |! |! |! |! |!




system control valve and fire command center, indicating which fire
|! |! |! |! |! |! |! |! |! |!




protection system, or part thereof, is out of service. |! |! |! |! |! |! |! |!




• Maintain the fire protection system in service until work is ready to begin.
|! |! |! |! |! |! |! |! |! |! |! |! |!




Who is authorized to place a tag on a system? - Correct answer ✔- master fire
|! |! |! |! |! |! |! |! |! |! |! |! |! |! |!




suppression piping contractor
|! |! |!




- FDNY
|!




- owner
|!




- master plumber (as restricted)
|! |! |! |!




What are the approved non freezing solutions for a sprinkler? - Correct
|! |! |! |! |! |! |! |! |! |! |! |!




answer ✔- glycerin not greater than 48%
|! |! |! |! |! |!




- propane glycol not greater than 38%
|! |! |! |! |! |!




What is a riser card? - Correct answer ✔Approved card baring dates of each
|! |! |! |! |! |! |! |! |! |! |! |! |! |!




inspection, COF # and COF signature |! |! |! |! |!




Where should the riser card be posted? - Correct answer ✔On the premises
|! |! |! |! |! |! |! |! |! |! |! |! |!




near the main water supply control valve
|! |! |! |! |! |!

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Ruiz Liberty University
View profile
Follow You need to be logged in order to follow users or courses
Sold
73
Member since
1 year
Number of followers
1
Documents
11341
Last sold
3 days ago
Top-Quality Study Materials for Success – Ace Your Exams with Expert Resources!

Access high-quality study materials to help you excel in your exams. Get notes, summaries, and guides tailored to your courses!

3.3

7 reviews

5
3
4
0
3
2
2
0
1
2

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions