Which of the following is NOT a type of dead-end access road.
T or hammerhead
cul-de-sac
alley dock
three point turn around - answer>>>three point turn around
Cooking equipment must have a clearance of at least __ inches from any combustible
material unless it is specifically designed for a lesser clearance.
A) 12
B) 18
C) 36
D) Dependant on AHJ - answer>>>18
Following a welding of thermal cutting operation, a fire watch must be maintained for at
least ______ after any job is completed.
A. 60 minutes
B. 30 minutes
C. 20 minutes
D. 15 minutes - answer>>>30 minutes
Dead end fire department access roads longer than 150 ft. must be provided with a:
A. Turnaround
B. Grass pave fire lane
C. Knox key switch
D. 13% road grade - answer>>>Turnaround
The presence of a nonflowing electrical charge that may develop on almost any surface.
a) Alternating current
b) static electricity
c) arcing electricity
d) direct current - answer>>>static electricity
,Following a welding or thermal cutting operation (also called hot work), a fire watch must
be maintained for at least _____ minutes after any job is completed.
A. 60
B. 15
C. 30
D. 120 - answer>>>30
Three primary storage methods?
a. pallet storage
b. rack storage
c. solid piling
d. all of the above - answer>>>all of the above
Inspectors should check all material-handling equipment within recycling facilities. These
include all of the following except:
A) Waste chutes and handling systems
B) Shredders
C) Extruders
D) Incinerators - answer>>>Incinerators
When certain high-hazard commodities such as vehicle tires, plastics, flammable liquids,
unused pallets, and the like are stored over ___ ft in and height and combustible
materials are stored over __ft, the storage is considered_____.
A.8, 12, high hazard storage
B.12, 20, high piled storage
C. 12, 20 high hazard solid stack storage
D. 6, 12, high piled storage - answer>>>6, 12, high piled storage
T or F: Dust explosions occur in series. The first explosion usually is not as severe as
subsequent explosions. - answer>>>True
A _______ is a brief spike in voltage, usually lasting millionths of a second, and one form
of electrical power disturbance that can create a fire hazard.
a) spark
b) arc
c) power surge (also known as voltage and transient surge)
d) ground fault - answer>>>power surge (also known as voltage and transient surge)
, For Recreational Fires, the fire itself should be no more than _____ feet from a structure
unless it's contained in a BBQ pit.
1. 15 feet
2. 20 feet
3. 25 feet
4. 12 feet - answer>>>25 feet
How does a power surge enter a building? A) Electrical Service Lines
B) Telephone Lines
C) Cable Television Lines
D) Satellite Dishes
E) All the Above. - answer>>>All the above
__________ is the movement of a current between two electrodes or conductors and
may result also result in a fire.
A. Voltage
B. Amperage
C. Arcing
D. Static electricity - answer>>>Arcing
Which of the following is a type of fire lane turnaround?
A) Oval Face
B) Ladder Dock
C) Hammerhead
D) Cobra - answer>>>Hammerhead
Code requirements for regulating "open burning" include the following: Uncontained fires
should not be allowed within feet of a structure?
A. 15
B. 10
C. 25
D. 50 - answer>>>50
According to the IFC Chapter 3 power point presentation , hot ashes and combustible
ignition sources are not supposed to be placed within ___ft of combustibles (including
walls), or within ____ft of building openings.
A) 10, 2
B) 100, 20
C) 1000, 200