Answers
D. All of the above - ANSWER How often, at a minimum, should ISO
Classification 5 environments be cleaned?
A. Beginning of each shift
B. Every 30 minutes when compounding
C. After Spills
D. All of the above
B. Low, Medium, High - ANSWER How are Risk Levels Classified?
A. Red, Yellow, Blue
B. Low, Medium, High
C. Sterile, Non-Sterile, Hazardous
D. None of the above
B. Pharmacy Director / Manager - ANSWER Who determines Risk Level?
A. Certification Technician/Professional
B. Pharmacy Director / Manager
C. USP
D. None of the above
C. Active, Passive - ANSWER Two Types of Air Sampling Include?
A. Sterile, Non-Sterile
B. Pre-Compounding, Post-Compounding
C. Active, Passive
D. None of the above
,A. Passive - ANSWER Which Type of Air Sampling is NOT Complaint with
USP 797?
A. Passive
B. Active
C. Impaction
D. Dual Method
C. Surface - ANSWER What Type of sampling requires plates to contain
neutralizers for cleaning chemicals?
A. Air
B. Control
C. Surface
D. None of the Above
C. 400 - 1000L - ANSWER When doing environmental air sampling, what
are the lower and upper limits for air volume?
A. 600 - 1100 CFM
B. 500 - 1000 M^3
C. 400 - 1000 L
D. Must be 1000L
A. Genus Level - ANSWER Environmental Monitoring Reports must report
down to?
A. Genus Level
B. Speciation Level
C. Colony Level
D. Genius Level
D. Once every Sample - ANSWER When, at a minimum, must your
gloves be disinfected when performing environmental air sampling?
, A. Once every 3x Samples
B. Once every 10 Minutes
C. Once ever 6x Samples
D. Once every Sample
B. Once every 5-6 samples - ANSWER When, at a minimum, must your
gloved be disinfected when performing environmental surface sampling?
A. Once every Sample
B. Once every 5-6 Samples
C. Once every 10 Minutes
D. Once every 3x Samples
C. TSA - ANSWER Which type of sampling plate MUST be used when
using the Single Plate Method?
A. GMA
B. SDA
C. TSA
D. MDA
C. 0 -
ANSWER
How many cfu
are allowed
during Finger
Tip Gowning
Validation?
A. <3
B. 1 - 3
C. 0
D. <5
C. <1 cfu/m^3 - ANSWER cfu limit for environmental AIR samples taken
from an ISO 5 environment?