Real Exam Questions and Verified Correct Answers
Which of the following systems is not covered by NFPA 25? - answer>>>High expansion foam
NFPA 25 states that the owner must have the fire protection system ________ prior to making any
changes in the occupancy, the use or process, or the materials stored or used in a building -
answer>>>Evaluated
Sprinkler systems using suppression mode sprinklers are generally designed for a maximum of ________
sprinklers operating - answer>>>12
Which of the following best describes the aspect of "flame spread"? - answer>>>The process of moving
a flame across the surface of a liquid or solid
Using the light hazard curve shown on Figure 11.2.3.1.1 in NFPA 13, what is the density required for a
sprinkler operating an area of 3000 ft2? - answer>>>.07 gpm/ft2
Which of the following BEST describes an advantage of automatic water-based suppression systems? -
answer>>>No need for human interaction or presence
Control mode sprinkler systems are designed for final extinguishment of the fire to be done ___. -
answer>>>manually
Water is the most common substance used for fighting fires. - answer>>>True
Which of the following is a duty of a water-based fire protection system inspector? -
answer>>>Technically proficient; always works safely
The heat release rate increases as the surface area of the fuel ___. - answer>>>increases
Automatic and manual water-based systems are never used together. - answer>>>False
, Which of the following BEST describes the study of fire dynamics? - answer>>>It is the study of how fires
start, spread, and grow
Which of the following is considered a very tall building? - answer>>>A building with occupied floors
that are beyond the capacity of the fire department apparatus to deliver sufficient water for firefighting
purposes
Whom of the following is responsible for maintaining a water-based fire protection system? -
answer>>>Property owner or designated representative
___ is the most universal agent used for fire control and extinguishment. - answer>>>Water
Inspection, testing, and maintenance activities must be conducted in accordance with ___ safety
regulations. - answer>>>applicable
Which of the following statements is true regarding access to fire protection system and components for
inspection, testing, and maintenance? - answer>>>NFPA 25 requires that the owner provide ready
accessibility for all areas of a building containing system components that require inspection, testing, or
maintenance.
Fires are classified to assist in determining the most efficient ___ for controlling, suppressing, or
extinguishing the fire. - answer>>>agent
Any abnormality observed during inspection or testing must be reported promptly to the ___. -
answer>>>owner
Professionalism includes all of the following except: - answer>>>Always wearing a tie
Water-based fire protection inspectors are required to follow all safe workplace practices. -
answer>>>True
Which of the following is not an aspect of fire dynamics? - answer>>>Heat Absorption