What must you do if you notice code violations in a homeowners house? - ANSWERNotify them and recommend ways to address them What must be done when performing an annual tune-up on a heating system? - ANSWERA combustion efficiency test and a copy must be posted on site Whenever a furnace, direct fired hot water heater, or boiler is installed the total installation must be brought into compliance with what requirements BEFORE appliance can be fired? - ANSWERNFPA 31 When an emergency arises that does not allow adequate time to get a chimney lined/and or repaired before installing the new heating appliance the licensee may defer the required repairs for how long? - ANSWER90 days What must be performed before a new installation? - ANSWERA heat loss system design and load calculation. A copy must be retained to be presented upon request of board inspector All oil fired BOILERS must be provided with a properly installed and operating what? - ANSWERLow Water cut off Where shall a low water cutoff be installed? - ANSWERAt the level recommended by the manufacture, but in no case below the crown sheet If the low water cut off is not installed directly in the boiler where may it be installed? - ANSWERMain supply line (vertical riser) as close to boiler as possible, or in a water column of continuous piping attached directly to the boiler A listed lever or wheel thermally operated oil shut off valve must be installed where? - ANSWERAt the burner and the oil supply tank When outside tanks are used a thermally operated shut off valve must be installed where? - ANSWERThe supply line enters the inside of the building and where the oil line enters the room where the appliance is located When inside tanks are used and the oil supply tank is installed in a separate room, a thermally shutoff valve must be installed where? - ANSWERWhere the line enters the room where the appliance is located Whenever the oil supply is taken from the top of an oil tank a thermally operated wheel or lever type shut-off valve must be installed where? - ANSWERAt the tank and at the burner What may be installed in the supply line but not a return line? - ANSWERA check valve All copper oil supply and return lines must be encased in a continuous piece of no metallic liquid tight conduit such as PVC, ENT, coated copper tubing. The end of the conduit shall not exceed how far from any connection except the connection at fuel tank? - ANSWER2 inches In order to avoid undetected oil leaks under floors, the conduit must be how much bigger than the supply and return lines? - ANSWEROne pipe size larger An oil supply line that penetrates a foundation wall must be what? - ANSWERSealed What must coated copper tubing have installed at the tank when used underground? - ANSWEROils Safety Valve or PRV When an oil filter or other accessory equipment is connected to a copper piping smaller than 3/4 "and is not directly connected to the oil tank or burner the filter or other device must be what? - ANSWERRigidly supported by wall or floor mounted brackets

Show more Read less
Institution
JOURNEYMAN OIL MAINE FUEL BOARD RULES
Course
JOURNEYMAN OIL MAINE FUEL BOARD RULES









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
JOURNEYMAN OIL MAINE FUEL BOARD RULES
Course
JOURNEYMAN OIL MAINE FUEL BOARD RULES

Document information

Uploaded on
May 16, 2025
Number of pages
13
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

JOURNEYMAN OIL MAINE FUEL
BOARD RULES QUESTIONAS &
ANSWERS(RATED A+)
What must you do if you notice code violations in a homeowners house? -
ANSWERNotify them and recommend ways to address them

What must be done when performing an annual tune-up on a heating system? -
ANSWERA combustion efficiency test and a copy must be posted on site

Whenever a furnace, direct fired hot water heater, or boiler is installed the total
installation must be brought into compliance with what requirements BEFORE
appliance can be fired? - ANSWERNFPA 31

When an emergency arises that does not allow adequate time to get a chimney
lined/and or repaired before installing the new heating appliance the licensee may
defer the required repairs for how long? - ANSWER90 days

What must be performed before a new installation? - ANSWERA heat loss system
design and load calculation. A copy must be retained to be presented upon request
of board inspector

All oil fired BOILERS must be provided with a properly installed and operating what?
- ANSWERLow Water cut off

Where shall a low water cutoff be installed? - ANSWERAt the level recommended by
the manufacture, but in no case below the crown sheet

If the low water cut off is not installed directly in the boiler where may it be installed?
- ANSWERMain supply line (vertical riser) as close to boiler as possible, or in a
water column of continuous piping attached directly to the boiler

A listed lever or wheel thermally operated oil shut off valve must be installed where?
- ANSWERAt the burner and the oil supply tank

When outside tanks are used a thermally operated shut off valve must be installed
where? - ANSWERThe supply line enters the inside of the building and where the oil
line enters the room where the appliance is located

When inside tanks are used and the oil supply tank is installed in a separate room, a
thermally shutoff valve must be installed where? - ANSWERWhere the line enters
the room where the appliance is located

Whenever the oil supply is taken from the top of an oil tank a thermally operated
wheel or lever type shut-off valve must be installed where? - ANSWERAt the tank
and at the burner

, What may be installed in the supply line but not a return line? - ANSWERA check
valve

All copper oil supply and return lines must be encased in a continuous piece of no
metallic liquid tight conduit such as PVC, ENT, coated copper tubing. The end of the
conduit shall not exceed how far from any connection except the connection at fuel
tank? - ANSWER2 inches

In order to avoid undetected oil leaks under floors, the conduit must be how much
bigger than the supply and return lines? - ANSWEROne pipe size larger

An oil supply line that penetrates a foundation wall must be what? - ANSWERSealed

What must coated copper tubing have installed at the tank when used underground?
- ANSWEROils Safety Valve or PRV

When an oil filter or other accessory equipment is connected to a copper piping
smaller than 3/4 "and is not directly connected to the oil tank or burner the filter or
other device must be what? - ANSWERRigidly supported by wall or floor mounted
brackets

If the entrance to the boiler room is only accessible from outside where will the
emergency switch be placed? - ANSWERInside the room not more than a foot
beyond the door opening. Never placed outside a building

Where will emergency switch be placed for commercial and industrial equipment? -
ANSWEROutside the entrance to the room containing the appliances

For steam safety or pressure relief valves which terminate inside the structure must
terminate how far above the floor? - ANSWER6 to 12 inches

Steam safety and pressure relief valves on boilers must be installed with the spindle
in what position? - ANSWERUpright vertical

What must supply and return lines be connected with? - ANSWERFlare fittings

What fittings shall not be used unless for introduction of lines at top of the tank with a
single or double tap bushing? - ANSWERCompression fittings

All connections of supply or return oil lines located outside must be made with what?
- ANSWERFlare frost fittings

Manholes 16 inches in diameter or larger must be installed in the top of all tanks over
what? - ANSWER5,000 gallons or more

All fuel oil supply tanks must be a minimum of how many feet from any gas or solid
fuel burning appliance? - ANSWER5 feet

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
papersbyjol West Virginia
View profile
Follow You need to be logged in order to follow users or courses
Sold
421
Member since
2 year
Number of followers
253
Documents
13947
Last sold
21 hours ago

3.8

72 reviews

5
27
4
18
3
17
2
2
1
8

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions