Lab Technician EXAM 90
QUESTIONS AND ANSWERS
ASTM Standard dealing with proper capping methods
C617
The procedure for capping enables concrete cylinders to meet the
standard's requirements for ____ and ____
Planeness and Perpendicularity
equipment needed for the capping process include ____, ____
devices, and ____ pots
plates, alignment, melting
Plates for neat cement and high-strength gypsum plaster caps
should be made of ____, ____, ____, or ____
glass, metal, granite, diabase
,Sulfur mortar cap plates should be formed against _____ or _____
metal or stone
The purpose of the guide bar or bullseye level is that caps remain
perpendicular to the axis of the cylinder within _____ degrees
.5
to avoid accidents during reheating, use melting pots that have
_____ _____
peripheral heating
The technician should use a stiff layer of _____ to cap fresh
concrete cylinders.
Neat Cement Paste
, Hardened concrete cylinders should be capped with _____ _____
_____ _____, _____ _____ _____, or _____ _____.
high strength gypsum paste, neat cement paste or sulfur mortar
Plaster of Paris and Portland Cement are examples of suitable
high-strength plasters. True or False?
False- They are not suitable
Sulfur mortars and high strength gypsum cement cubes must
demonstrate a minimum compressive strength of _____ or _____;
whichever is greater.
5000 psi or 35 MPa or the cylinder's strength
The cement paste should be applied to the freshly molded
cylinders from _____ to ______ hours after molding. This is to allow
______ of the concrete specimen.
2 to 4, setting