J1 CALIFORNIA RESIDENTIAL INSPECTOR FINAL
EXAM COMPLETE 250 QUESTIONS WITH DETAILED
VERIFIED ANSWERS (100% CORRECT ANSWERS)
/ALREADY GRADED A+/ BRAND NEW!!!
correct or incorrect. Concrete mixing and the delivery of it
shall comply with ASTM C 94. - Answer-correct
Wood structural panels used as roof sheathing with a span
rating of 40/20 shall have a maximum span of _____
inches when no edge support is provided and the panel
thickness used is 5/8 inch thick. - Answer-32
The maximum slope of a ramp serving an egress door
shall not have more than a ____ slope. - Answer-1:12
Smoke alarms shall comply with the requirements of NFPA
72 and shall be listed to conform with which standard? -
Answer-UL 217
Each dwelling unit shall be provided with at least one
egress door providing a clear width of not less than ____
inches. - Answer-32
,2|Page
The minimum uniformly distributed live load for exterior
balconies shall be: - Answer-60 lbs/sf
The maximum riser height of a stairway shall be _____
inches and the minimum tread depth shall be _____
inches. - Answer-7 3⁄4 , 10
Emergency escape and rescue openings located at grade
floor shall have a minimum clear opening area of not less
than _____ square feet. - Answer-5
The flame spread index of wall and ceiling finishes shall
not be greater than ___ and the smoke-developed index
shall not be greater than ___. Tests conducted shall
conform with ASTM E 84 or UL ___. - Answer-200, 450,
723
Two-family dwellings provided with a sprinkler system
shall have the units separated by a wall and floor
assembly having a fire-resistance rating of not less than
______. - Answer-1⁄2 hour
, 3|Page
Garages shall be separated from habitable rooms directly
above the garage with a minimum of _________. -
Answer--inch Type X gypsum board
Exterior walls of non-sprinklered dwellings having a fire
separation distance of 5 feet shall have a minimum fire-
resistance rating of ____ hours. - Answer-Zero
A habitable room within a dwelling unit is required to have
a floor area of no less than ____ square feet. - Answer-70
Which of the following roof slopes can you NOT
install asphalt shingles as a roof covering? - Answer-1:12
correct or incorrect. 2 x 3 wood studs are not allowed to be
used in exterior walls. - Answer-correct
Fireblocking within concealed spaces of wood- framed
stud walls shall be spaced horizontally at intervals not
exceeding _____. - Answer-10 feet