Residential Building Inspector Exam|Brand New Exam Questions with 100% Correct Verified Answers|All Graded A+|100% Guaranteed Success|Latest Expert Premium Update(). Which do not fall under the purview of the international residential code? - ANSWER Any building larger than a two-family dwelling I.E. an apartment building Which of the following requires a permit? A. installing a new central heating and cooling system B. installing a through the window air conditioning unit C. replacing an existing lamp attached to the ceiling of an interior hallway D. installing portable heating units - ANSWER A. installing a new central heating and cooling system The international residential code requires which one of the following? A. plans must be submitted in electronic media B. the approved plans shall be kept at the site of the work C. the building official retains the plans for 7 years after completion of project D. construction documents must be prepared by a registered design professional - ANSWER B. the approved plans shall be kept at the site of the work Prefabricated walls shall be installed in accordance with the _________? - ANSWER approved plans A permit is not required for the construction of a one-story detached accessory structure when it has a maximum floor area of ___________ square feet. - ANSWER 200 The fire-resistance-rated wall assembly between the dwelling units in a two_family dwelling must _________. - ANSWER be tested in accordance with ASTM E 119 or UL 263 Where in the international residential code would I find exposure categories? - ANSWER Section R301.2.1.4 PG. 44 Windows within 2 feet of a lot line, but located in a wall which is perpendicular to the lot line ___________ - ANSWER are permitted What is the minimum area for a habitable room within a dwelling unit other than a kitchen? - ANSWER 70 sq ft What is the minimum ceiling height for a habital room? - ANSWER 7 feet Not less than one exit door shall be provided for each dwelling. The door must be ________. - ANSWER side hinged Protection from decay is required when wood is ______. - ANSWER used in the locations indicated in section R317.1 Photovoltaic panels are to be installed on an existing buildings roof. Panels must be located at least 3 feet from the _________? - ANSWER roof ridge The ________ of a manufactured home must be located above the design flood elevation or base flood elevation plus one foot. - ANSWER bottom frame Where would I look to determine the seismic design category? - ANSWER Table R301.2.2.1.1 PG 46 What is the load bearing capacity of silty gravel in pounds per square foot? - ANSWER 2,000

Show more Read less
Institution
Residential Building Inspector
Course
Residential Building Inspector









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Residential Building Inspector
Course
Residential Building Inspector

Document information

Uploaded on
May 2, 2025
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Residential Building Inspector
Exam|Brand New Exam Questions
with 100% Correct Verified
Answers|All Graded A+|100%
Guaranteed Success|Latest Expert
Premium Update(2025-2026).




Which do not fall under the purview of the international residential code? -
ANSWER✅✅ Any building larger than a two-family dwelling I.E. an apartment
building

Which of the following requires a permit?

A. installing a new central heating and cooling system
B. installing a through the window air conditioning unit
C. replacing an existing lamp attached to the ceiling of an interior hallway
D. installing portable heating units - ANSWER✅✅ A. installing a new central heating
and cooling system

The international residential code requires which one of the following?

A. plans must be submitted in electronic media
B. the approved plans shall be kept at the site of the work
C. the building official retains the plans for 7 years after completion of project

, D. construction documents must be prepared by a registered design professional -
ANSWER✅✅ B. the approved plans shall be kept at the site of the work

Prefabricated walls shall be installed in accordance with the _________? -
ANSWER✅✅ approved plans

A permit is not required for the construction of a one-story detached accessory
structure when it has a maximum floor area of ___________ square feet. -
ANSWER✅✅ 200

The fire-resistance-rated wall assembly between the dwelling units in a two_family
dwelling must _________. - ANSWER✅✅ be tested in accordance with ASTM E 119
or UL 263

Where in the international residential code would I find exposure categories? -
ANSWER✅✅ Section R301.2.1.4
PG. 44

Windows within 2 feet of a lot line, but located in a wall which is perpendicular to
the lot line ___________ - ANSWER✅✅ are permitted

What is the minimum area for a habitable room within a dwelling unit other than a
kitchen? - ANSWER✅✅ 70 sq ft

What is the minimum ceiling height for a habital room? - ANSWER✅✅ 7 feet

Not less than one exit door shall be provided for each dwelling. The door must be
________. - ANSWER✅✅ side hinged

Protection from decay is required when wood is ______. - ANSWER✅✅ used in the
locations indicated in section R317.1

Photovoltaic panels are to be installed on an existing buildings roof. Panels must be
located at least 3 feet from the _________? - ANSWER✅✅ roof ridge

The ________ of a manufactured home must be located above the design flood
elevation or base flood elevation plus one foot. - ANSWER✅✅ bottom frame

Where would I look to determine the seismic design category? - ANSWER✅✅
Table R301.2.2.1.1
PG 46

What is the load bearing capacity of silty gravel in pounds per square foot? -
ANSWER✅✅ 2,000

For a crawlspace foundation, the international residential code requires the wood
sole plate to be anchored to the foundation with anchor bolts spaced _________. -

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BRILLIANTSOLUTIONS St Johns River State College Orange Park
View profile
Follow You need to be logged in order to follow users or courses
Sold
56
Member since
2 year
Number of followers
2
Documents
2723
Last sold
1 week ago
A+SCIENCE SOLUTIONS HUB

GET THE LATEST EXPERTLY SOLVED REVISION,ACTUAL EXAMS,FINAL ,MID-TERM EXAMS AND RETAKES EXAM MATERIALS IN ALL SCIENCE COURSES AT AN AFFORDABLE PRICE.

3.1

7 reviews

5
2
4
1
3
1
2
2
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions