ARRT MRI MOCK REGISTRY EXAM QUESTIONS AND ANSWERS UPDATED (2024/2025) (VERIFIED ANSWERS) If the heart rate is 70 beats per minute, the R-R interval (effective TR) would be calculated as such: 60,000 milliseconds (60 seconds per minute, and there are 1000 milliseconds per second) ÷ 70 (heart rate) which = 857 milliseconds TR. If the desire is to null the signal from a specific tissue using an inversion recovery sequence, the inversion time (TI) selected should be ______ of the T1 relaxation time of that tissue. A. 37% B. 43% C. 63% D. 69% E. 82% - ANS 69% If the desire is to null the signal from a specific tissue using an inversion recovery sequence, the inversion time (TI) selected should be 69% of the T1 relaxation time of that tissue.2 ARRT ARRT MRI In order to generate thin slices, a ___________ is used. I. Steep slice selection gradient II. High amplitude slice select gradient III. Low amplitude slice select gradient IV. Narrow transmit bandwidth (tBW) V. Wide transmit bandwidth (tBW) VI. Narrow receiver bandwidth (rBW) - ANS I. Steep slice selection gradient II. High amplitude slice select gradient IV. Narrow transmit bandwidth (tBW) Magnetic susceptibility artifacts are more prominent with _____________ sequences. A. Inversion recovery B. Spin echo C. Gradient echo D. Fast spin echo - ANS Gradient echo Which of the following field strengths would require the shortest TI time to suppress the signal from fat when performing a STIR sequence in an MRI of the ankle? A. 0.5T B. 1.0T3 ARRT ARRT MRI C. 1.5T D. 3.0T - ANS 0.5T As the TR is increased, I. SNR is increased II. Available number of slices is increased III. T2 information is maximized A. I only B. II only C. I and II only D. I and III only E. I, II and II - ANS I and II only

Show more Read less
Institution
Course











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Course

Document information

Uploaded on
April 25, 2025
Number of pages
55
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

1
ARRT



ARRT MRI MOCK REGISTRY EXAM QUESTIONS
AND ANSWERS UPDATED (2024/2025)
(VERIFIED ANSWERS)


If the heart rate is 70 beats per minute, the R-R interval (effective TR)

would be calculated as such: 60,000 milliseconds (60 seconds per minute,

and there are 1000 milliseconds per second) ÷ 70 (heart rate) which = 857

milliseconds TR.



If the desire is to null the signal from a specific tissue using an inversion

recovery sequence, the inversion time (TI) selected should be ______ of the

T1 relaxation time of that tissue.

A. 37%

B. 43%

C. 63%

D. 69%

E. 82% - ANS ✓69%



If the desire is to null the signal from a specific tissue using an inversion

recovery sequence, the inversion time (TI) selected should be 69% of the

T1 relaxation time of that tissue.




ARRT MRI

, 2
ARRT



In order to generate thin slices, a ___________ is used.

I. Steep slice selection gradient

II. High amplitude slice select gradient

III. Low amplitude slice select gradient

IV. Narrow transmit bandwidth (tBW)

V. Wide transmit bandwidth (tBW)

VI. Narrow receiver bandwidth (rBW) - ANS ✓I. Steep slice selection gradient

II. High amplitude slice select gradient

IV. Narrow transmit bandwidth (tBW)



Magnetic susceptibility artifacts are more prominent with _____________

sequences.

A. Inversion recovery

B. Spin echo

C. Gradient echo

D. Fast spin echo - ANS ✓Gradient echo



Which of the following field strengths would require the shortest TI time to

suppress the signal from fat when performing a STIR sequence in an MRI of

the ankle?

A. 0.5T

B. 1.0T


ARRT MRI

, 3
ARRT
C. 1.5T

D. 3.0T - ANS ✓0.5T



As the TR is increased,

I. SNR is increased

II. Available number of slices is increased

III. T2 information is maximized

A. I only

B. II only

C. I and II only

D. I and III only

E. I, II and II - ANS ✓I and II only



Creating additional images in various planes from a 3D data set is

accomplished by a technique known as:

A. Subtraction

B. Maximum intensity projection (MIP)

C. Region of interest calculation(ROI)

D. Multi-Planar reconstruction (MPR)

E. Minimum Intensity Projection (MinIP) - ANS ✓Multi-Planar reconstruction

(MPR)




ARRT MRI

, 4
ARRT
In a Fast Spin Echo (FSE) sequence, acquired with a long TE, yielding T2

weighted images, scan time can be reduced by:

A. Increasing the FOV

B. Increasing NEX

C. Using shorter ETL

D. Using longer ETL

E. Increasing phase encodings - ANS ✓Using longer ETL



The gradient slew rate is the:

A. Time it takes longitudinal magnetization to regrow

B. Time between TI and initial RF pulse

C. Time it takes for the gradient to reach its full amplitude

D. Rate of speed of ascent or descent of a gradient from zero to its

maximum amplitude - ANS ✓Rate of speed of ascent or descent of a gradient

from zero to its maximum amplitude



Droplet contamination frequently occurs via:

A. Sharing the MRI scanner control mouse

B. Routine breathing

C. Patting on the back

D. Coughing - ANS ✓Coughing




ARRT MRI

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
NurseAdvocate chamberlain College of Nursing
Follow You need to be logged in order to follow users or courses
Sold
405
Member since
1 year
Number of followers
70
Documents
11035
Last sold
1 week ago
NURSE ADVOCATE

I have solutions for following subjects: Nursing, Business, Accounting, statistics, chemistry, Biology and all other subjects. Nursing Being my main profession line, I have essential guides that are Almost A+ graded, I am a very friendly person: If you would not agreed with my solutions I am ready for refund

4.6

227 reviews

5
187
4
13
3
11
2
4
1
12

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions