KY HVAC JOURNEYMAN Exam 100 Questions
and Correct Detailed Answers Already A+ 2025
Liquid adhesive coatings used on air filters for air conditioning or heating systems shall
have a flash point not lower than _______ :
a: 200°F
b: 250°F
c: 350°F
d: 325°F -Correct Answer ✔d: 325°F
Refer: IMC Code 605.1
Connectors shall connect to a chimney flue at a point not less than ______ above the
lowest portion of the interior of the chimney flue:
a: 10 inches
b: 12 inches
c: 16 inches
d: 14 inches -Correct Answer ✔b: 12 inches
Refer: IMC Code 801.12
Liquids having flash points at or above 100°F (38°C) and below 140°F (60°C) comes under
________ combustible liquid:
a: Class I
b: Class II
c: Class IIIA
d: Class IIIB -Correct Answer ✔b: Class II
KY HVAC JOURNEYMAN
,KY HVAC JOURNEYMAN
Where located adjacent to walkways, the vertical termination of mechanical draft
systems shall be not less than ______ above the level of the walkway:
a: 7 feet
b: 5 feet
c: 3 feet
d: 4 feet -Correct Answer ✔a: 7 feet
Refer: IMC Code 804.3.5.1
Commercial kitchen Grease duct systems serving a Type I hood shall be designed and
installed to provide an air velocity within the duct system of not less than ______ feet
per minute:
a: 1000
b: 500
c: 400
d: 250 -Correct Answer ✔b: 500
Refer: IMC Code 506.3.4
The minimum openable area to the outdoors shall be ____ of the floor area being
naturally ventilated:
a: 6%
b: 8%
c: 4%
d: 2% -Correct Answer ✔c: 4%
Refer: IMC Code 504.7
KY HVAC JOURNEYMAN
, KY HVAC JOURNEYMAN
Fire dampers are not required at penetrations of shafts where the steel exhaust
subducts extend at least _______ vertically in exhaust shafts provided that there is a
continuous airflow upward to the outdoors:
a: 25 inches
b: 22 inches
c: 32 inches
d: 28 inches -Correct Answer ✔b: 22 inches
Refer: IMC Code 607.5.5 Exp 1.1
Underground Ducts shall have a minimum slope of _______ per foot to allow drainage to
a point provided with access:
a: 1/2 inch
b: 1/6 inch
c: 1/4 inch
d: 1/8 inch -Correct Answer ✔d: 1/8 inch
Refer: IMC Code 603.8.1
Masonry chimney flues shall be provided with a cleanout opening having a minimum
height of ______ :
a: 6 inches
b: 12 inches
c: 8 inches
d: 10 inches -Correct Answer ✔a: 6 inches
Refer: IMC Code 801.13
Commercial Kitchen Exhaust equipment serving a Type I hood shall have a clearance to
combustible construction of not less than ______ :
KY HVAC JOURNEYMAN