ARDMS BREAST SONOGRAPHY EXAM 2025 NEWEST 2
VERSIONS (VERSION A AND VERSION B) COMPLETE
QUESTIONS AND CORRECT DETAILED ANSWERS
(VERIFIED ANSWERS) |ALREADY GRADED A+||BRAND NEW
VERSION!!!
Terms in this set (268)
0. According to AIUM C. SSN
standards, all of the
following information
should be indicated on
sonographic images of the
breast EXCEPT:
A. Patient's name/ ID #
B. Patient's age
C. Patient's social security
number
D. Facility name
E. Date
Which of the following is D. all of the above
considered an appropriate
annotation method for
breast imaging?
A. Side/quadrant
B. Clock-face
C. 123-ABC
D. All of the above
E. None of the above
… 1/69
,4/4/25, 1:22 PM ARDMS BREAST SONOGRAPHY EXAM 2025 NEWEST 2 VERSIONS (VERSION A AND VERSION B) COMPLETE QUESTIONS …
Which of the following A. if the gain and filter settings are too low, it can cause noise
statements would be
FALSE when considering
Doppler artifacts?
A. If the gain and filter
settings are too low, it can
cause noise.
B. If the filter setting is
too high, it will inhibit the
ability to detect low-
velocity blood flow.
C. A PRF/velocity scale that
is too low will cause
aliasing.
D. If the Doppler angle is
perpendicular to flow, no
flow will be detected
E. Spectral mirroring causes
a duplication of the
waveform on the opposite
… 2/69
,4/4/25, 1:22 PM ARDMS BREAST SONOGRAPHY EXAM 2025 NEWEST 2 VERSIONS (VERSION A AND VERSION B) COMPLETE QUESTIONS …
Which statement is E. B&C
TRUE for
propagation speed
error?
A. If the propagation speed
is slower than 1540 m/sec,
posterior echoes will
be displayed on the
sonogram more anterior
than they actually are.
B. If the propagation speed
is slower than 1540 m/sec,
posterior echoes will
be displayed on the
sonogram deeper than they
actually are.
C. If the propagation speed
is faster 1540 m/sec,
reflectors will appear
closer to the transducer than
they actually are.
D. A and B
E. B
and C
The brightness of echoes C frequency
on an ultrasound image is
affected by all of the
following EXCEPT:
A. Overall gain
B. Power output
C. Transducer frequency
D. Dynamic range
E. TGC
… 3/69
, 4/4/25, 1:22 PM ARDMS BREAST SONOGRAPHY EXAM 2025 NEWEST 2 VERSIONS (VERSION A AND VERSION B) COMPLETE QUESTIONS …
Which one of the following C. present the informed consent to the patient for signature
steps would NOT be part of
the examination
Preparation?
A. Obtain pertinent clinical
information from the
patient
B. Explain the examination to
the patient.
C. Present the informed
consent to the patient for
signature.
D. Review pertinent
correlative imaging tests.
E. Know the indication for the
exam.
The supine oblique position: E. all of the above
A. Evenly distributes the breast
tissue
B. Allows better evaluation
of the outer breast
C. Places the nipple in the
center. .
D. Minimizes breast
thickness for better
penetration
E. All of the above
Echo palpation is used to: D. A&B
A. Localize a mass
B. Determine if a mass is
compressible or not
C. Determine if a mass is
malignant or benign
D. A and B
E. All of the above
48. For general breast e. supine oblique, and contralateral anterior oblique
scanning, which patient
position is considered
best?
A. Supine oblique
B. Contralateral anterior
oblique
… 4/69