QUESTION BANK/ NACE CIP LEVEL 1 | 2025
ACCURATE REAL EXAM QUESTIONS WITH
DETAILED VERIFIED ANSWERS GRADED A+ |
GUARANTEED EXCELLENCE PASS
(Also known as 'fisheyes' or 'crawling') is the term for surface breaks in the film
that reveal the substrate. It is often a result of grease or oil contamination on the
substrate. - ✔✔✔ Correct Answer > Cissing
Which standard gives guidelines for how many DFT measurements should be
taken in a given area? - ✔✔✔ Correct Answer > SSPC PA 2
The powerful standard for cleaning to bare metal with a minimum profile of 1 Mill
(25.4microns) is: - ✔✔✔ Correct Answer > SSPC SP 11
Which one of the following documents is the best source for coating technical
data: - ✔✔✔ Correct Answer > Technical Data Sheet
Which is a component that supplies most of the features and functions of the
material? - ✔✔✔ Correct Answer > Binder
You are on a job and observe the coating being applied in an unacceptable
manner. As the Inspector you should? - ✔✔✔ Correct Answer > Report to the
Contractor's Supervisor and Report to the Owner's Representative.
,What is the minimum recommended distance away from an edge that an
inspector should take a measurement with a dial type magnetic pull off Dry Film
Thickness (DFT) gauge? - ✔✔✔ Correct Answer > 2.5 cm (1 inch)
Polymerization is the process of? - ✔✔✔ Correct Answer > Monomers joining
together.
An exposed area of the substrate or previous coat of a conductive material, often
caused by poor application technique is called: - ✔✔✔ Correct Answer > Holiday
Checking is: - ✔✔✔ Correct Answer > a fine crack in the surface of a coating that
rarely reaches the substrate.
Inspection documentation is important because: - ✔✔✔ Correct Answer >
Owners use the documentation for a variety of purposes.
An Inspectors personal log book should contain: - ✔✔✔ Correct Answer > No
comments regarding the application team.
You have just received your NACE CIP Level 1 certification when you are asked to
supervise a team of uncertified field pipeline inspectors. Your FIRST preferred
course of action is to: - ✔✔✔ Correct Answer > Review the NACE Attestation
prior to making a decision.
,Good record can provide maintenance departments with detailed information
about ALL of the following EXCEPT: - ✔✔✔ Correct Answer > How the item was
coated.
Non-Conformance Reports are completed by the Inspector: - ✔✔✔ Correct
Answer > When the Inspector and Contractor deem it to be significant non-
conforming item.
The initial steel condition is important to the NACE Inspector because: - ✔✔✔
Correct Answer > The Inspector may have to reject the steel.
The form of corrosion that has the largest potential for unexpected catastrophic
failure is: - ✔✔✔ Correct Answer > Galvanic Corrosion
What is used to determine compressed air cleanliness? - ✔✔✔ Correct Answer >
Profilometer
Osmotic blistering is most likely to occur as a result of: - ✔✔✔ Correct Answer >
Airless spray application.
When performing tests for oil and grease using an ultra violet light, the NACE
Inspector should be aware that: - ✔✔✔ Correct Answer > Synthetic oil or grease
may not be identified.
To achieve consistently accurate results with ALL alt test equipment: - ✔✔✔
Correct Answer > wash your hands before sampling.
, When holiday testing is required the Inspector is always required to enforce what
standard? - ✔✔✔ Correct Answer > NACE SP 0188
If the specifier does not identify a restriction level in accordance with SSPC PA 2,
the default restriction level is: - ✔✔✔ Correct Answer > Level 3
Fine cracks in the surface of a coating that rarely reach the substrate are called: -
✔✔✔ Correct Answer > Checking
It is good practice for the NACE Inspector to have instrument calibration
certificates available: - ✔✔✔ Correct Answer > At all times.
In a non-convertible coating the role of the primary solvent is to: - ✔✔✔ Correct
Answer > To control the evaporation rate.
Removal of weld splatter is required: - ✔✔✔ Correct Answer > When specifically
identified in the owners specification.
Common errors that may produce inaccurate readings when using a Dial Type
Magnetic Pull Off Dry Film Thickness (DFT) gauge include: - ✔✔✔ Correct Answer
> Failing to determine the Base Metal Reading (BMR), Rotating the dial too fast
when taking measurements, and Measuring ditty, tacky, or soft films.
Conventional spray us good choice when: - ✔✔✔ Correct Answer > High quality
finishes are required.
Which of these tests uses a syringe? - ✔✔✔ Correct Answer > Bresle Patch