FSDNY S-98 2025/2026 EXAM QUESTIONS WITH CORRECT DETAILED ANSWERS || ALREADY GRADED A+ &lt;LATEST VERSION&gt; 1. This is regarding manual fire alarm boxes, NFPA 72 requires that they be conspicuous, unobstructed, and ________ - ANSWER accessible 2. Regarding manual fire alarm boxes, NFPA 72 requires that travel distance to the nearest fire alarm Box shall not exceed - ANSWER 100 feet 3. The maximum number of water flow switches permitted to be connected to a single IDC shall not exceed - ANSWER 5 4. Fire pumps shall be supervised for: (find the incorrect answer) - ANSWER Pump running - supervisory signal 5. After the first initial or reactance inspection, nickel-cadmium and sealed acid batteries shall be inspected - ANSWER Semi-annually 6. The first functionality test of a smoke detector shall be performed _______________. - ANSWER within one year of installation 7. A minimum of _______ detectors shall be tested on each initiating conventional device circuits. - ANSWER two 8. The fire alarm system transmitters shall be visually inspected at least _________. - ANSWER semi-annually 9. Supervised alarm notification appliances shall be visually inspected at least ________. - ANSWER semi-annually 10. A DACT is required to be visually inspected ________________. - ANSWER semi-annually 11. A DACT is required to be tested ____________. - ANSWER annually 12. The proper method to measure the voltage across battery terminals when performing a lead battery charger test is to _____________________. - ANSWER leave the battery connected to the charger circuit 13. When cleaning a smoke detector you should first, ____________________. - ANSWER read the manufactures cleaning procedures. 14. _________________ does not ensure that each smoke detector is within its listed ranges. - ANSWER A smoke entrance method 15. A notification appliance is located at the end of a 24V circuit. The device requires at least 24 volts in order to operate. ______ gage size wires are needed for this device to operate. (NFPA 20) - ANSWER 14 16. The wire nuts used in NYC to splice fire alarm conductors must be rated at a temperature of _______. - ANSWER 150c 17. The requirements for grounding a fire alarm system are based on ____________________. - ANSWER NYC electrical code Article 250. 18. ____________ of the national electrical code addresses the requirements for fire alarm. - ANSWER Article 760 19. ______ AWG is the minimum required wire for grounding a fire alarm system in NYC. - ANSWER 8 20. ______ AWG is the stranded wire allowed to be used in NYC fire alarm installations. - ANSWER 8 21. Article _______ of the National Electrical Code addresses the requirements for fire-stopping. - ANSWER 300 (NFPA 70 article 300.21)

Show more Read less
Institution
FSDNY S98
Course
FSDNY S98










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
FSDNY S98
Course
FSDNY S98

Document information

Uploaded on
February 15, 2025
Number of pages
21
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

FSDNY S-98 2025/2026 EXAM QUESTIONS
WITH CORRECT DETAILED ANSWERS ||
ALREADY GRADED A+
<LATEST VERSION>




1. This is regarding manual fire alarm boxes, NFPA 72 requires that they be
conspicuous, unobstructed, and ________ - ANSWER accessible

2. Regarding manual fire alarm boxes, NFPA 72 requires that travel distance to
the nearest fire alarm Box shall not exceed - ANSWER 100 feet

3. The maximum number of water flow switches permitted to be connected to a
single IDC shall not exceed - ANSWER 5

4. Fire pumps shall be supervised for: (find the incorrect answer) - ANSWER
Pump running - supervisory signal

5. After the first initial or reactance inspection, nickel-cadmium and sealed acid
batteries shall be inspected - ANSWER Semi-annually

6. The first functionality test of a smoke detector shall be performed
_______________. - ANSWER within one year of installation

7. A minimum of _______ detectors shall be tested on each initiating
conventional device circuits. - ANSWER two

8. The fire alarm system transmitters shall be visually inspected at least
_________. - ANSWER semi-annually

,9. Supervised alarm notification appliances shall be visually inspected at least
________. - ANSWER semi-annually

10.A DACT is required to be visually inspected ________________. -
ANSWER semi-annually

11.A DACT is required to be tested ____________. - ANSWER annually

12.The proper method to measure the voltage across battery terminals when
performing a lead battery charger test is to _____________________. -
ANSWER leave the battery connected to the charger circuit

13.When cleaning a smoke detector you should first, ____________________.
- ANSWER read the manufactures cleaning procedures.

14._________________ does not ensure that each smoke detector is within its
listed ranges. - ANSWER A smoke entrance method

15.A notification appliance is located at the end of a 24V circuit. The device
requires at least 24 volts in order to operate. ______ gage size wires are
needed for this device to operate. (NFPA 20) - ANSWER 14

16.The wire nuts used in NYC to splice fire alarm conductors must be rated at a
temperature of _______. - ANSWER 150c

17.The requirements for grounding a fire alarm system are based on
____________________. - ANSWER NYC electrical code Article 250.

18.____________ of the national electrical code addresses the requirements for
fire alarm. - ANSWER Article 760

19.______ AWG is the minimum required wire for grounding a fire alarm
system in NYC. - ANSWER 8

20.______ AWG is the stranded wire allowed to be used in NYC fire alarm
installations. - ANSWER 8

21.Article _______ of the National Electrical Code addresses the requirements
for fire-stopping. - ANSWER 300 (NFPA 70 article 300.21)

, 22.The standard fire alarm evacuation is a ________ pulse temporal pattern
using any appropriate sound. - ANSWER Three

23.Upon recite of a trouble signal/supervisory signal, the central station shall
notify the subscriber's representatives within ________. - ANSWER 4
minutes

24.Based on the 1968 building code, a coded alarm signal shall consist of not
less than _____ of the number transmitted. Each number shall consist of
______. - ANSWER four rounds; three impulses

25.By NYC fire code definition, an unnecessary alarm is considered to be an
alarm ________________________. - ANSWER caused by a cigarette
smoke from a lit cigarette in a non-smoking area.

26.A certificate of of Fitness holder, after observing smoke detectors which
appear to be painted shall __________________________________. -
ANSWER make a log and notify the building owner that the smoke
detectors need to be replaced.

27.The minimum distance between a smoke detector and an air supply should
be _________. - ANSWER 3 Feet

28.A smoke detector maintenance log book must be readily accessible on
premises for a period of ___________ from the original entry. - ANSWER 3
years

29.A central station log book should be kept for a minimum of ________ from
the original entry. - ANSWER 6 years

30.Crossed zone circuits are utilized especially where detectors
_________________. - ANSWER initiate a discharge of an extinguishing
system

31.According to RCNY 907-01, it is unlawful to transmit two or more
unnecessary alarms in any period of ____________. - ANSWER three
months

32.The correct heat detector to be used to address thermal lag is
_________________. - ANSWER Rate Compensation Detector

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
DocBritiney Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
13
Member since
9 months
Number of followers
1
Documents
46
Last sold
1 week ago
DOCBRITINEY

Get comprehensive solutions for all subjects, covering both assignments and major exams. Reach out if you need any help. Best of luck! I provide clear, well-researched educational materials with expertise in Nursing, Mathematics, Psychology, Biology, and more. My resources include up-to-date exam solutions, verified study guides, and notes—100% guaranteed.

4.0

1 reviews

5
0
4
1
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions