100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

609 ESCO 100% EXPERT VERIFIED CORRECT AND UPDATED 2025!

Rating
-
Sold
-
Pages
5
Grade
A+
Uploaded on
06-02-2025
Written in
2024/2025

609 ESCO 100% EXPERT VERIFIED CORRECT AND UPDATED 2025! Contaminated refrigerants must be handled with some extra precautions. If you are unsure about a refrigerant, EPA strongly recommends (but does not require) that technicians obtain a refrigerant identifier as a useful tool. When a technician encounters a "mystery" refrigerant, it must be recovered using a piece of equipment dedicated to this purpose. Unapproved refrigerants may contain a high percentage of flammable substances, such as propane or butane, and a fire hazard may result. Check with your equipment manufacturer to be sure the equipment has protection against risks of ignition. Once the refrigerant has been recovered, it must be properly stored and/or sent to a reclamation facility to be reclaimed or destroyed. Refrigerants From Non-Mobile Sources Refrigerant recovered from non-mobile sources, such as residential or commercial air conditioners or refrigeration systems may not be used in MVAC systems or reco --- correct answer ---page 5

Show more Read less
Institution
609 ESCO
Course
609 ESCO

Content preview

609 ESCO 100% EXPERT VERIFIED CORRECT
AND UPDATED 2025!


Contaminated refrigerants must be handled with some extra precautions. If you
are unsure about a refrigerant, EPA strongly recommends (but does not require)
that technicians obtain a refrigerant identifier as a useful tool. When a technician
encounters a "mystery" refrigerant, it must be recovered using a piece of
equipment dedicated to this purpose. Unapproved refrigerants may contain a high
percentage of flammable substances, such as propane or butane, and a fire hazard
may result. Check with your equipment manufacturer to be sure the equipment has
protection against risks of ignition. Once the refrigerant has been recovered, it
must be properly stored and/or sent to a reclamation facility to be reclaimed or
destroyed. Refrigerants From Non-Mobile Sources Refrigerant recovered from non-
mobile sources, such as residential or commercial air conditioners or refrigeration
systems may not be used in MVAC systems or reco --- correct answer ---page 5




HFO-1234yf The Hydro Fluoro Olefin Refrigerant HFO-1234yf was developed
through a joint project between Chemours (Formally DuPont) and Honeywell. HFO-
1234yf is expected to become the preferred global alternative refrigerant candidate
for automotive OEM applications and the aftermarket. HFO-1234yf has a GWP of 4
and an ODP of zero. HFO-1234yf has a cooling capacity that is comparable to HFC-
134a and is compatible with HFC-134a components. Furthermore, this refrigerant
does have a flammability factor, which will need to be addressed prior to its
adoption as a substitute for HFC-134a. Recovery Cylinders Recovery cylinders
differ in many ways from disposable cylinders. A disposable cylinder such as those
used for new product, are not refillable and MUST NEVER be used for recovery.
Recovery cylinders are specifically designed to be refilled. Recovery cylinders have
at least two ports, one vapor and one liquid. The EPA is --- correct answer ---page
6

, Manifold Gauge Set When servicing a system with a manifold gauge set, the high,
low, and center hoses must have shut off valves within 12 inches (30 cm) of the
service ends. Shut off valves can be manually operated or close automatically when
the hose is removed. During all service operations, the shut off valves should be
closed until connected to the system or the charging source to prevent the
introduction of air and to contain rather than vent any refrigerant. When the gauge
set is removed from the vehicle or charging source, it must be connected to the
recovery equipment to recover the refrigerant from the hoses. Recycling
Requirements Approved recycling equipment must meet all of the criteria that
recovery only equipment must meet. In addition, recycling equipment must clean
the used refrigerant to the minimum purity level as defined in SAE standards
before it can be used in a motor vehicle air conditioning sys --- correct answer ---7




When using an electronic leak detector, always follow the manufacturer's
operating instructions. In addition to the manufacturer's instructions, the
following should be observed: 1. Always leak test with the engine off. 2. Only, a
small amount of refrigerant is required to perform a leak test. A gauge reading of
50 psi is all that is needed. At temperatures below 50°F., leaks may not be
measurable, since 50 psi may not be attainable. 3. To avoid contaminating the tip
of your leak detector, remove excessive dirt from suspected leak areas. Do not use
cleaners or solvents, your detector may be sensitive to their ingredients. 4.
Visually inspect the system, and look for signs of air conditioning oil leakage,
damage, and corrosion on all lines, hoses, and components. Each suspected area
should be carefully checked. 5. Follow the system around in a continuous path to
ensure that no areas are missed. If a leak is found, con --- correct answer ---page 8




concerning the issue of leak repairs. 7 Proper Charging and Recharging of MVAC
Systems After system evacuation, and dehydration the system can be charged with

Written for

Institution
609 ESCO
Course
609 ESCO

Document information

Uploaded on
February 6, 2025
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PASSINGMASTER01 Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
460
Member since
4 year
Number of followers
333
Documents
2804
Last sold
7 hours ago
TIGHT DEADLINE? I CAN HELP Many students don't have the time to work on their academic papers due to balancing with other responsibilities, for example, part-time work. I can relate. kindly don't hesitate to contact me, my study guides, notes and exams

QUALITY DOCUMENTS FOR BEST RESULTS. In my page you will find latest Exams ,Assignments, Test Banks, Exam Elaboration, test with Questions and Answers, Discussions, Case Studies, package deals, etc. I upload quality. Instant delivery.

3.7

42 reviews

5
21
4
6
3
5
2
3
1
7

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions