100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

NCCER 26401 LOAD CALCULATIONS-FEEDER AND SERVICES NEWEST VERSION 2025/2026 ACTUAL QUESTION AND CORRECT DETAILED VERIFIED ANSWERS FROM VERIFIED SOURCES RATED A GRADE.

Rating
4.0
(1)
Sold
-
Pages
24
Grade
A+
Uploaded on
03-02-2025
Written in
2024/2025

NCCER 26401 LOAD CALCULATIONS-FEEDER AND SERVICES NEWEST VERSION 2025/2026 ACTUAL QUESTION AND CORRECT DETAILED VERIFIED ANSWERS FROM VERIFIED SOURCES RATED A GRADE.

Institution
NCCER 26401 LOAD CALCULATIONS-FEEDER AND SERVICES
Course
NCCER 26401 LOAD CALCULATIONS-FEEDER AND SERVICES










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NCCER 26401 LOAD CALCULATIONS-FEEDER AND SERVICES
Course
NCCER 26401 LOAD CALCULATIONS-FEEDER AND SERVICES

Document information

Uploaded on
February 3, 2025
Number of pages
24
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • nccer 26401
  • nccer

Content preview

NCCER 26401 LOAD CALCULATIONS-FEEDER
AND SERVICES NEWEST VERSION 2025/2026
ACTUAL QUESTION AND CORRECT DETAILED
VERIFIED ANSWERS FROM VERIFIED SOURCES
RATED A GRADE.

Save




Terms in this set (113)


What is the minimum NEC 220.43 (A) Show windows 30ft x 200va = 6000 va
demand required for the
portion of a feeder that
supplies 30ft of show
window?

Residential Small apliance 1500 va
circuits must be rated at
__________ per NEC 220.52(A)

When performing load 60 amps
calculations for farm
buildings the load that
must be included in the
calculation at 100%
demand must be at least
_______ .

The demand lighting load 220. 14(M) 1.7 volt amperes per square foot. 18,000 va
for a 20,000 square foot
motel with no dining room
or ballroom is ____ per NEC
220.12 and 220.42

,What is the demand 72,000 va
lighting load for a 100,000
square foot hotel with no
dining room or ballroom is
____ per 220.12 and 220.42 ?

When calculating the Determine the sum of all the motor loads plus 25% of
feeder load for a motor the largest motor.
Control Center supplying
several Motors per 430.24
you must ______ .

A commercial kitchen with 65% demand factor
six or more pieces of
kitchen equipment is
subject to a demand
factor of ___________ per NEC
table 220.56.

When the overcurrent protection for a conductor is
What is a tap conductor? located on the load side rather than the supply side
of a conductor, it is considered to be a tap conductor

What is the minimum 3va per s.f.
general lighting load in
volt-amps per square foot
required by the NEC table
220.12 for a store?

•120a x 50ft = 6000
What is the total load
•110a x 60ft = 6600
center length for a tapped
•75a x 90ft = 6750
feeder with loads of 120a
•70a x 150ft = 10,500
at 50 feet, 110a at 60 feet,
•6000+6600+6750+10,500 = 29,850
75a and 90 feet, and 70
•120a+110a+75a+70a = 375a
amps at 150 feet?
•29,a = 79.6 ft load center length

, The minimum ampacity for •Table 555.12
a feeder supplying ten •9-14 receptacles @ 80%
30a shore power •10 receptacles x 30a = 300a
receptacles in a marina is •Apply the demand factor from 555.12 300a x 80% =
_____ per NEC table 555.12 240a

The minimum ampacity for •Table 555.12
a feeder supplying (30) •15-30 receptacles @ 70%
shore power receptacles •30 receptacles x 30a = 900a
in a marina each rated at •Apply the demand factor from 555.12 900a x 70% =
30a is _____ per NEC table 630a
555.12.

•What is the total load for •Use Table 430.250
a feeder serving •7.5 amps x 4 = 30a
•(4) 2 horsepower motors •16.7amps x 3 = 50.1a
7.5a • 46.2 amps x 1= 46.2a
•(3) 5 horsepower • 74.8 amps x 100% = 74.8
Motors16.7a •74.8a x .25% = 18.7a (add
•(1) 15 horsepower 46.2a additional 25% for largest motor
motor load)
•(1) 25 horsepower motor •30+50.1+46.2+74.8+18.7=219.8a or
? 74.8a 30+50.1+46.2+93.5 = 219.8a
•(all Motors are 208 volts)

What is the feeder •84,563 va / 208volts = 406.5522
ampacity for a three •Don’t forget it’s three phase! = 1.732
phase, 120/208 Volt •406..732 = 234.89a
subpanel with a
connected load of 84,563
Volt amps?

Using the Volt amps per •200va x 50ft = 10,000va
linear foot method, the •“Total” means include Continuous load
total Volt amps that must • 10,000va x 1.25 = 12,500va
be used in a service
calculation for a 50 foot
show window is ____ per
NEC 220.43(A).

Reviews from verified buyers

Showing all reviews
9 months ago

4.0

1 reviews

5
0
4
1
3
0
2
0
1
0
Trustworthy reviews on Stuvia

All reviews are made by real Stuvia users after verified purchases.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Drvivek Johns Hopkins University School Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
195
Member since
1 year
Number of followers
1
Documents
191
Last sold
7 hours ago

4.5

229 reviews

5
147
4
49
3
25
2
7
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions