100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

IMSA Traffic Signal Technician 2 Exam | Questions and Answers Rated A+ | Latest Update 2025/2026

Rating
-
Sold
-
Pages
19
Grade
A+
Uploaded on
27-01-2025
Written in
2024/2025

IMSA Traffic Signal Technician 2 Exam | Questions and Answers Rated A+ | Latest Update 2025/2026 IMSA Traffic Signal Technician 2 Exam | Questions and Answers Rated A+ | Latest Update 2025/2026 IMSA Traffic Signal Technician 2 Exam | Questions and Answers Rated A+ | Latest Update 2025/2026

Show more Read less
Institution
Imsa
Course
Imsa










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Imsa
Course
Imsa

Document information

Uploaded on
January 27, 2025
Number of pages
19
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • imsa
  • imsa 2025
  • imsa 2026

Content preview

IMSA Traffic Signal Technician 2 Exam |
Questions and Answers Rated A+ |
Latest Update 2025/2026


During scheduled preventative maintenance the Tech observes that the
catenary wire is cut next to a street sign on a span wire. What should the
tech do? - Correct Answer - Install a Strandvice inline of catenary wire,
and make a note in the work order for management to schedule
replacement of catenary wire.



After a trouble call, the tech observes that the catenary 9/16" strandvise
at the concrete pole is broken. What should the tech do? - Correct
Answer - Using a come along, loosen the 9/16" wire then remove the
broken 9/16" strandvise. Install the new 9/16" strandvise onto the eyebolt
on the pole than pull the 9/16" catenary steel wire through the strandvise
and release the tension on the come along slowly.



When replacing a signal head, what is NOT important? - Correct Answer
- Manufacturer of signal.



How does the technician know that signal poles are installed in the
correct locations? - Correct Answer - Check the intersection
schematics/drawings.

,Glancing at the cabinet wiring schematic, how can a technician know
they are working in a NEMA TS-1 8 phase cabinet? - Correct Answer -
Controller is connected to cabinet wiring using 3-4 multiwire connectors.



What is the BEST test instrument to assist the Tech for locating bad fiber
optic splices or cut fiber optic cables in the field? - Correct Answer -
Optical Time Domain Reflectometer (OTDR)



What testing device would a tech use to verify continuity of a detector
home run cable? - Correct Answer - Multimeter.



What is a way to verify the UPS has been connected and is operating
properly? - Correct Answer - Turn off the main breaker at the electric
service disconnect.



During inspection of the UPS connected at the traffic signal, the tech
notices one of four batteries has expanded and bubbled. What is the
recommended response? - Correct Answer - Test other batteries, and
replace the expanded bubbled battery along with other failing batteries.



Which of the following MUST be done after changing the UPS batteries?
- Correct Answer - Document initial battery voltages and work done in
the traffic signal cabinet log book.

, What should you do if the signal indications do not function properly after
replacing the faulty signals? - Correct Answer - Review cabinet
blueprints to verify the wiring method.



In a NEMA TS1 cabinet, a loop detector provides a call or input to the
controller by providing - Correct Answer - 12 VDC to the controller on the
input pin



Which statement does NOT include a step to evaluate detection inputs
to the controller? - Correct Answer - Perform a "one-call" to check for
any utilities located underground.



An approach has four signal heads for the through lanes, three overhead
and one on the corner. In a cabinet without load resistors, how many
reds have to fail before the CMU/MMU in the cabinet puts the cabinet in
flash? - Correct Answer - 3



Which alternative below presents a correct action to inspect a pedestrian
actuation? - Correct Answer - Use multimeter to verify voltage and
continuity of wiring connected to the push button.



While visible solder bubbles are acceptable in soldering joints, we should
re-solder if there is any soldering leaking through the jumper board. -
Correct Answer - False

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
nursehailey Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
2308
Member since
5 year
Number of followers
1358
Documents
3478
Last sold
1 day ago

3.9

533 reviews

5
261
4
110
3
74
2
25
1
63

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions