A colles fracture commonly involves the following: - ANS-posterior and outward displacement of
the hand and a chip fracture of the ulnar styloid technique
a tool used to ensure reproducible radiographs, no matter tissue density versions, is the -
ANS-computerized exposure manage
a dose of 0.25 Gy or 25 rad to the fetus during the latter part of the primary trimester of
pregnancy is much more likely to cause - ANS-neurologic abnormalities
a patient aged fifty five years is maximum appropriately defined as - ANS-middle adult
a affected person's feeling of spinning, or the room spinning round him, is referred to as -
ANS-vertigo
a patient's iv container should be hung - ANS-18-24 inches above the vein
a postvoid image of the urinary bladder is normally requested at the of completion of an
intravenous urogram and may be helpful in demonstrating: - ANS-residual urine and prostate
enlargement
A radiographer have to recognize that gerontologic patients regularly have passed through
bodily adjustments that include loss of - ANS-muscular tissues and bone calcium
A radiographer who discloses exclusive facts to unauthorized people can be determined
accountable for - ANS-defamation
A radiographer who plays an x-ray examination on a affected person with out the affected
person's consent , or after the patient has refused the exam, can be chargeable for -
ANS-battery
a best receptor exposure become obtained the usage of 12 mAs and four hundred mA. What
exposure time could be required to produce the identical receptor exposure using 1200 mA -
ANS-10 ms
ABC is used in fluoroscopy to adjust the - ANS-kilovoltage and milliamperage
accurate operation of the AEC device depends on - ANS-positioning of the object with
appreciate to the photocell and beam restrict
benefits of flat panel fluoroscopy consist of - ANS-decreased affected person dose and
extended temporal decision
advantages of LED display over LCD display include - ANS-much less power consumption,
advanced lights, and thinner design
blessings of moving the picture intensifier towards the patient throughout conventional
fluoroscopy consist of - ANS-reduced patient dose and stepped forward image great
even though the stated focal spot length is measured immediately underneath the actual focal
spot, focal spot length in reality varies along the duration of the x-ray beam. At which part of the
x-ray beam is the powerful focal spot the smallest - ANS-anode stop
an AEC tool can operate on which of the following standards - ANS-a PMT charged through a
fluorescent display and a parallel-plate ionization chamber charged with the aid of x-ray photons
an set of rules, as used in xray imaging, - ANS-is a series of variable commands
, an axial projection of the clavicle is regularly helpful in demonstrating a fracture now not
visualized using a perpendicular important ray. When examining the clavicle in the AP axial
projection, how have to the critical ray be directed - ANS-cephalic
An person's legal file identifying his or her specific wishes concerning hospital treatment to be
furnished in the event that she or he is unable to make or talk decisions is referred to as -
ANS-advanced fitness care directive
and publicity turned into made the use of 2 hundred mA, 50 ms exposure, and seventy five kv.
What adjustments would effectively double radiographic receptor exposure - ANS-alternate to
0.1-s exposure, alternate to 86 kv, and exchange to twenty mAs
as a result of the anode heel effect, x-ray beam intensity is finest alongside the - ANS-cathode
quit of the beam
as digital photograph matrix size increases - ANS-Pixel size decreases, resolution will increase,
pixel depth will increase
as electrons impinge at the anode floor, less than 1% of their kinetic strength is modified to -
ANS-x-rays
As the size of the picture matrix increases in digital imaging - ANS-pixel size decreases and
spatial decision increases
Aspirated foreign our bodies in older kids and adults are maximum probable to lodge within the -
ANS-right most important bronchus
axial CT pix may be reconstructed to coronal images in order to reveal - ANS-anterior/posterior
relationships
earlier than bringing the patient into the radiographic room, the radiographer need to - ANS-be
sure the xray room is smooth and orderly, check that all essential add-ons are to be had in the
room, take a look at the xray table is clean and pillowcases are clean
blood stress is measured in gadgets of - ANS-millimeters of mercury (mm Hg)
blunting of the costophrenic angles seen on a PA projection of the chest may be a
demonstration of - ANS-pleural effusion
frame reaction to a sensitizing agent can arise because of - ANS-absorption, injection, and
ingestion
characteristics of the metal detail tungsten encompass - ANS-prepared dissipation of heat, high
melting point, and high atomic number
chest radiography should be done the use of seventy two-inch SID every time possible as a way
to - ANS-visualize vascular markings and acquire better lung element
circuit devices that permit electrons to flow in simplest one course are - ANS-solid-country
diodes
computed radiography decision increases as - ANS-laser beam length decreases and PSP
crystal length decreases
situations that make contributions to x-ray tube harm consist of - ANS-prolonged anode rotation
and exposures to a cold anode
CT gantry additives consist of - ANS-x-ray tube and detector array
shipping of huge exposures to a cold anode or the use of exposures exceeding tube hindrance
can result in - ANS-cracking of the anode and rotor bearing damage
layout characteristics of x-ray tube targets that determine warmth potential include - ANS-the
rotation of the anode, diameter of the anode, and size of the focal spot