100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

PLUMBING LEVEL 3 EXAM ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY GRADED A

Rating
-
Sold
-
Pages
93
Grade
A
Uploaded on
17-12-2024
Written in
2024/2025

Terms in this set (127) A journeyman plumber and an apprentice, who are employed by a master plumber, are installing the DWV- system and water distribution system in a 2-½ story single family dwelling. QUESTION: What answer below shall be considered most correct to complete the following "Plumbing code knowledge" related statement: A trap that serves a single shower stall that is equipped with a hand shower, a rain head, and a standard shower head shall be no less than ________ in minimum diameter A) 1-½" B) 2" C) 2-½" D) 3" 2 inches 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G… A journeyman plumber and apprentice are installing 3-inch floor drains in an open- parking-garage that is subject to freezing temperatures. QUESTION: What answer below shall be considered most correct to complete the following "Plumbing code knowledge" related statement: The installation of traps at the floor drain locations which are found susceptible to freezing temperatures may be __________. A)Increased to 4-inch B) Eliminated C) Wrapped with freeze protection cable D) Insulated eliminated 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G… A journeyman plumber and apprentice are installing lab sinks with faucets that are connected to an acid waste system for- (special hazardous waste) in a medical lab. What answer below shall be considered most correct to complete the following "Plumbing code knowledge" related statement: Vacuum breakers shall be installed with the critical level at least _____-inches above the flood level rim of the fixture they serve and on the discharge side of the last control valve to the fixture. A) 12 B) 6 C) 18 D) 3 6 inches 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G… What answer below shall be considered most correct to complete the following "Plumbing code knowledge" related statement: No plumbing permit shall be issued for cross connection installations that require ______________ until the application for a permit is accompanied by a letter of approval from the Massachusetts Department of Environmental Protection or its designee. A) RPBP B) A "critical level" height C) Atmospheric vacuum breakers D) Water recycling systems reduced pressure backflow preventer (RPBP) 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G… : What answer below shall be considered most correct to complete the following "Plumbing code knowledge" related statement: The waste discharge from safe waste pans serving water heaters or hot water storage tanks where there is _______ below and shall be piped indirectly to a properly trapped and vented fixture. A) People B) Occupancy C) Floors D) Plumbing connections occupancy 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G… GIVEN: A journeyman plumber and an apprentice, (who are employed by a master plumber), are installing the sanitary DWV and water distribution system in a five-story residential condominium complex. QUESTION: What answer below shall be considered most correct to complete the following "Plumbing code knowledge" related statement: CPVC- (Chlorinated Polyvinyl Chloride) pipe and fittings may be used provided that none of this material is located within ____-inches of any connection to a hot water tank as defined in MGL. c. 142, § 17 A) 12 B) 18 C) 20 D) 24 E) 30 24 inches 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G… : A journeyman plumber and apprentice are roughing-in multiple fixtures in a new fitness center. The facility will include a juice bar, temporary daycare room, men's and women's toilet facilities and men's and women's locker rooms. QUESTION: What answer below shall be considered most correct to complete the following "Plumbing code knowledge" related statement: A ________-vent is a branch vent that serves two or more floor-outlet fixtures that are battery wasted. The vent extends from the top of the horizontal soil and/or waste branch in front of the last fixture waste and connects to a vent stack or stack vent that is adjacent to the down-stream end of the horizontal branch. A) Side B) Loop C) Relief D) Circuit loop 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G… MATCH: Elevated pressure Flow designation Ten P.S.I.G. or less Less than 2-P.S.I A) 3 P.S.I.G. or ten times B) Inlet pressure C) E.H.D. D) Prof. Engineer elevated pressure- d flow designation-c Ten P.S.I.G. or less-a Less than 2-P.S.I-b N: A journeyman plumber is installing category-I gas appliances and equipment in the basement of a building. A 120,000 BTU/hr. boiler and 40,000 BTU/hr. water heater are being installed. QUESTION: What answer below shall be considered most correct to complete the following "Gas code knowledge" related statement: The boiler requires a minimum of _____-cu. ft. of air to support proper combustion A) 2,400 cu. ft. B) 120 sq. in. C) 3,200 sq. ft. D) 800 cu. ft. 2,400 cu. ft. 120,000/50 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G… ) QUESTION: What answer below shall be considered most correct to complete the following "Gas code knowledge" related statement: The code would require the gas vent penetrating the roof in-[FIGURE-TP-B- Q1-1A: GAS VENT SIZING] as identified at point-[A] to be not less than ______ above any portion of a building within 10-feet horizontally. A) 24" B) 3-feet C) 30- inches D) Forty-two- inches 24

Show more Read less
Institution
PLUMBING LEVEL 3
Course
PLUMBING LEVEL 3











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
PLUMBING LEVEL 3
Course
PLUMBING LEVEL 3

Document information

Uploaded on
December 17, 2024
Number of pages
93
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM 2024-2025 ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G…




PLUMBING LEVEL 3 EXAM 2024-2025 ACTUAL
EXAM 60 QUESTIONS AND CORRECT
DETAILED ANSWERS |ALREADY GRADED A


Practice questions for this set


Learn 1 /7 Study with Learn




Reforming pocket



Choose matching term



A journeyman plumber/gas-fitter is connecting schedule-40 steel gas piping to a
natural gas fired roof-top heating and air conditioning unit that has been place
on the roof of a 1-story commercial building by the HVAC mechanical contractor.
QUESTION: What answer below shall be considered most correct to complete
1 the following "Gas code knowledge" related statement: The journeyman
plumber/gas-fitter is responsible to determine that this gas equipment has been
placed or set on its curb at least ______ from the roof's edge.

A) 8-feet B) 6-feet C) 5-feet D) 4-feet




https://quizlet.com/985457417/plumbing-level-3-exam-2024-2025-actual-exam-60-questions-and-correct-detailed-answers-already-graded-a-flash-car… 1/93

,12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM 2024-2025 ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G…

) GIVEN: A journeyman and apprentice plumber are completing the installation
of a vacuum powered sanitary drainage systems. The system is in a supermarket
serving drainage connections for vegetable and produce display coolers.
QUESTION: What answer below shall be considered most correct to complete
the following "Plumbing code knowledge" related statement: The image
2 presented in-[FIGURE-TP-B-Q1-4B: VACUUM DRAINAGE SYSTEM
KNOWLEDGE] IS known as a _______ and represents a method of assembling pipe
and fittings in a manner to re-establish a waste slug.

A) Accumulator B) Vacuum interface C) Collector D) Reforming pocket E) No
answer is correct




: A journeyman plumber has installed a 3-inch cast iron horizontal branch drain in
the basement of a building. The overall length of the branch is 42-feet.
QUESTION: What answer below shall be considered most nearly correct to
complete the following "Plumbing math knowledge" related statement: When
3
filled with water for the purpose of a rough underground plumbing inspection
the capacity in gallons of the branch will be approximately ________.

A) 10 to 12 B) 12 to 14 C) 15 to 17 D) 20 to 22




Ice machines =
Residential dishwasher =
Drips or drainage outlets =
Standpipe-(clothes washer) =
4
Safe waste pans =
Sterile materials=

air gap, air break either



Don't know?




https://quizlet.com/985457417/plumbing-level-3-exam-2024-2025-actual-exam-60-questions-and-correct-detailed-answers-already-graded-a-flash-car… 2/93

,12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM 2024-2025 ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G…

Terms in this set (127)

A journeyman plumber 2 inches
and an apprentice, who
are employed by a
master plumber, are
installing the DWV-
system and water
distribution system in a
2-½ story single family
dwelling. QUESTION:
What answer below
shall be considered
most correct to
complete the following
"Plumbing code
knowledge" related
statement: A trap that
serves a single shower
stall that is equipped
with a hand shower, a
rain head, and a
standard shower head
shall be no less than
________ in minimum
diameter


A) 1-½" B) 2" C) 2-½" D)
3"




https://quizlet.com/985457417/plumbing-level-3-exam-2024-2025-actual-exam-60-questions-and-correct-detailed-answers-already-graded-a-flash-car… 3/93

, 12/15/24, 11:39 AM PLUMBING LEVEL 3 EXAM 2024-2025 ACTUAL EXAM 60 QUESTIONS AND CORRECT DETAILED ANSWERS |ALREADY G…

A journeyman plumber eliminated
and apprentice are
installing 3-inch floor
drains in an open-
parking-garage that is
subject to freezing
temperatures.
QUESTION: What
answer below shall be
considered most
correct to complete the
following "Plumbing
code knowledge"
related statement: The
installation of traps at
the floor drain locations
which are found
susceptible to freezing
temperatures may be
__________.


A)Increased to 4-inch B)
Eliminated C) Wrapped
with freeze protection
cable D) Insulated




https://quizlet.com/985457417/plumbing-level-3-exam-2024-2025-actual-exam-60-questions-and-correct-detailed-answers-already-graded-a-flash-car… 4/93

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
OliviaWest Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
110
Member since
1 year
Number of followers
17
Documents
8528
Last sold
6 days ago
Pure Orchid Haven.

All Documents,and package deals offered by seller Olivia West.

2.8

22 reviews

5
6
4
2
3
4
2
1
1
9

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions