Inspector Standards {ACI CTCI} Combined
Exam Tested Questions With Revised
Correct Detailed Answers
>Latest Update>>
1. Special Inspector Exam - GR (General Requirements)
1. Who hires the special inspector?
a) The Building Official
b) The Contractor
c) The Owner
d) The RDP - ANSWER (c) or (d)
"The owner or the RDP in charge acting as the owner's agent is required to hire
the special inspector." -p. 19 in the Special Inspection Manual
2. Who prepares the statement of special inspections?
a) The Building Official
b) The Contractor
c) The Owner
d) The RDP - ANSWER d) The RDP
, 3. Who can deem special inspections unnecessary?
a) The Building Official
b) The Contractor
c) The Owner
d) The RDP - ANSWER a) The Building Official
"Special inspections are not required for work of a minor nature or as warranted
by conditions in the jurisdiction as approved by the building official." -Section
1704.1 in the IBC
4. What do you do if you see a discrepancy, notify the contractor, and nothing
gets done? - ANSWER Notify the RDP and the Building Official immediately
and the item should be noted in the special inspection report.
5. Do fixed discrepancies need to be included in reports? - ANSWER Yes, on
both occasions.
Occasion 1: Discrepancy noticed, reported to the contractor, and immediately
fixed. Still goes in the report.
Occasion 2: Discrepancy noticed, reported to the contractor, not fixed, reported
to the RDP and Bldg Official, then fixed. Still goes in the report.
5. What is a report of a technical finding? - ANSWER I've searched the SI
Manual, the IBC, and google for this term and can't find it anywhere. The closest
things I can find are: