OIL BURNER LICENSE EXAM AND PRACTICE EXAM NEWEST ACTUAL EXAM COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+ .#2 fuel oil stored in outside above ground storage tanks in cold climates can cause: - ANSWER--Waxing -Higher CO2 levels -Soot .A "sealed and insulated chimney system" requires: - ANSWER-High static burner .A burner in a confined space using 1 GPH of #2 fuel oil requires what size permanent opening for combustion air? - ANSWER-140" .A common breach draft for an oil appliance is: - ANSWER--.03 to -.06 .A common over the fire draft for an oil appliances - ANSWER--.01 to -.02 .A common source of air leakage into the chimney is: - ANSWER-Loose fitting clean out door at base of chimney .A condition often overlooked on a call involving odors is: - ANSWER-Insufficient air in the boiler room .A fuel oil storage tank cannot be installed: - ANSWER-In the furnace room within 5 feet of the heating unit .A high CO2 reading is caused by.. - ANSWER-Incomplete combustion .A layer of soot 1/16" thick will increase fuel consumption by: - ANSWER-4% .A material with electrons so loose it allows voltage to pass with little or no resistance.. - ANSWER-Is a conductor .A method of dealing with low viscosity/cold temps with #2 oil? - ANSWER-Increase pump pressure/ decrease nozzle size .A one-pipe system: - ANSWER-Must NOT have the bypass plug inserted in the pump. .A properly set up and adjusted oil fire appliance should produce a CO2 measurement of: - ANSWER-10% to 12% .A pump in a one pipe system that is full of air can be self purged. - ANSWER-False .A reverse acting aquastat is used in a hydronic system to: - ANSWER-Stop the circulator when the water temperature falls below a preset temperature .A significant difference between the CO2 or O2 reading at the flue pipe and over the fire is indication of: - ANSWER-Air leakage in the boiler .A simple, effective, yet inexpensive way to increase on-cycle system efficiency is to: - ANSWER-Match the nozzle to the heating load .A single stationary conductor in the flux of a permanent magnet will: - ANSWER--NOT induce a current flow in the conductor -NOT reverse the current flow in the conductor -NOT increase the amperage in the conductor .A stack switch is no longer allowed to be installed or replaced because.. - ANSWER-It's safety cutout time is higher than what is now required. .A stack thermometer commonly has a range from: - ANSWER-200° to 1000° .A steam pigtail should always be installed between the pressuretrol and the boiler to: - ANSWER-Place a water seal between the boiler and the pressuretrol .A technician is servicing an oil fired appliance that uses a cad cell primary control. The control locks out after a brief period of time. Which of the following can cause this to happen? - ANSWER-The cad cell does not sense light. .A typical ignition transformer is of what type? - ANSWER-Step-up .A typical residential zone valve for a hot water heating system normally operates on: - ANSWER-24 volts .A zero smoke and low CO2 or high O2 reading could be caused by: - ANSWER-Too much excess air .According to NFPA 31-2001, what is the minimum size of the fill pipe on an oil storage tank? - ANSWER-1 1/4" .Air is composed of oxygen and nitrogen in what percentages? - ANSWER-21 and 79 .An acceptable smoke test reading for new modern equipment is: - ANSWER-Between #0 and #1 .An advantage of power venting is: - ANSWER--Installing an oil fired unit where there is no chimney -More positive control of draft -Lower cost of new homes .An electrical switch that proves proper draft has been established is called what? - ANSWER-Air proving switch .An often overlooked cause of a high CO2 reading is.. - ANSWER-Not enough combustion air in the equipment room. .Atomizing type burners were designed to burn which type of fuel? - ANSWER-#2 oil .Because burner fans have beveled blades any dirt or lint in the blade will: - ANSWER-Reduce the amount of air for combustion .Because of the cad cell eye's limited sensing range, it can only be used effectively to: - ANSWER-Monitor an oil flame .Before installing a new nozzle the service technician should: - ANSWER-Flush out the nozzle line and adapter .Before lowering the temperature of a hot water boiler, consideration must be given to the: - ANSWER-Design of the heating system .Breaking up oil into small droplets is called: - ANSWER-Atomization .Burner air fans are manufactured to very close tolerances because an unbalanced fan can: - ANSWER--Put a strain on motor bearings -Create vibrations .Burner ignition systems normally operate at what primary voltage? - ANSWER-120 V .Burner ignition transformers operate at what secondary voltage range? - ANSWER-10,000 to 14,000 V

Show more Read less
Institution
Oil Burner License
Course
Oil Burner License










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Oil Burner License
Course
Oil Burner License

Document information

Uploaded on
November 13, 2024
Number of pages
26
Written in
2024/2025
Type
Exam (elaborations)
Contains
Unknown

Content preview

OIL BURNER LICENSE EXAM AND PRACTICE
EXAM NEWEST ACTUAL EXAM COMPLETE
QUESTIONS AND CORRECT DETAILED
ANSWERS (VERIFIED ANSWERS) |ALREADY
GRADED A+
.#2 fuel oil stored in outside above ground storage tanks in cold climates can cause: - ANSWER--Waxing

-Higher CO2 levels

-Soot



.A "sealed and insulated chimney system" requires: - ANSWER-High static burner



.A burner in a confined space using 1 GPH of #2 fuel oil requires what size permanent opening for combustion
air? - ANSWER-140"



.A common breach draft for an oil appliance is: - ANSWER--.03 to -.06



.A common over the fire draft for an oil appliances - ANSWER--.01 to -.02



.A common source of air leakage into the chimney is: - ANSWER-Loose fitting clean out door at base of chimney



.A condition often overlooked on a call involving odors is: - ANSWER-Insufficient air in the boiler room



.A fuel oil storage tank cannot be installed: - ANSWER-In the furnace room within 5 feet of the heating unit

,.A high CO2 reading is caused by.. - ANSWER-Incomplete combustion



.A layer of soot 1/16" thick will increase fuel consumption by: - ANSWER-4%



.A material with electrons so loose it allows voltage to pass with little or no resistance.. - ANSWER-Is a
conductor



.A method of dealing with low viscosity/cold temps with #2 oil? - ANSWER-Increase pump pressure/ decrease
nozzle size



.A one-pipe system: - ANSWER-Must NOT have the bypass plug inserted in the pump.



.A properly set up and adjusted oil fire appliance should produce a CO2 measurement of: - ANSWER-10% to
12%



.A pump in a one pipe system that is full of air can be self purged. - ANSWER-False



.A reverse acting aquastat is used in a hydronic system to: - ANSWER-Stop the circulator when the water
temperature falls below a preset temperature



.A significant difference between the CO2 or O2 reading at the flue pipe and over the fire is indication of: -
ANSWER-Air leakage in the boiler



.A simple, effective, yet inexpensive way to increase on-cycle system efficiency is to: - ANSWER-Match the
nozzle to the heating load



.A single stationary conductor in the flux of a permanent magnet will: - ANSWER--NOT induce a current flow in
the conductor

, -NOT reverse the current flow in the conductor

-NOT increase the amperage in the conductor



.A stack switch is no longer allowed to be installed or replaced because.. - ANSWER-It's safety cutout time is
higher than what is now required.



.A stack thermometer commonly has a range from: - ANSWER-200° to 1000°



.A steam pigtail should always be installed between the pressuretrol and the boiler to: - ANSWER-Place a water
seal between the boiler and the pressuretrol



.A technician is servicing an oil fired appliance that uses a cad cell primary control. The control locks out after a
brief period of time. Which of the following can cause this to happen? - ANSWER-The cad cell does not sense
light.



.A typical ignition transformer is of what type? - ANSWER-Step-up



.A typical residential zone valve for a hot water heating system normally operates on: - ANSWER-24 volts



.A zero smoke and low CO2 or high O2 reading could be caused by: - ANSWER-Too much excess air



.According to NFPA 31-2001, what is the minimum size of the fill pipe on an oil storage tank? - ANSWER-1 1/4"



.Air is composed of oxygen and nitrogen in what percentages? - ANSWER-21 and 79



.An acceptable smoke test reading for new modern equipment is: - ANSWER-Between #0 and #1



.An advantage of power venting is: - ANSWER--Installing an oil fired unit where there is no chimney
$16.99
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
BESTPRICE

Get to know the seller

Seller avatar
BESTPRICE EXAMS
View profile
Follow You need to be logged in order to follow users or courses
Sold
0
Member since
1 year
Number of followers
0
Documents
36
Last sold
-
BESTPRICE

Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers. We specialize on NURSING,WGU,ACLS USMLE,TNCC,PMHNP,ATI and other major courses, Updated Exam, Study Guides and Test banks. If you don't find any document you are looking for in this store contact us and we will fetch it for you in minutes, we love impressing our clients with our quality work and we are very punctual on deadlines. Please go through the sets description appropriately before any purchase and leave a review after purchasing so as to make sure our customers are 100% satisfied. I WISH YOU SUCCESS IN YOUR EDUCATION JOURNEY

Read more Read less
0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions