When working on an exchanger tube side hydro test, the - ANS CHANNEL HEAD
How many bolts need to be removed from a 12 bolt flange when installing gasket? - ANS 5
One of the main factors to consider when installing an orifice plate is: - ANS Direction of flow
When cutting a stud bolt, which end of the bolt should be saved? - ANS - STAMPED
- STENCILED
- MARKED
The method of pulling and rigging out an exchanger bundle without equipment is called a CONVENTIONAL pull. - ANS - TRUE
One of the most common internal components used to slow the f called a.
DEMISTER_ pad. - ANS - TRUE
Bundle straps should be aligned with the
exchanger bundle BAFFLE plate when rigging an - ANS - TRUE
SOFTENERS..
should be put into place when chokers come into contact with sharp surfaces or edges. - ANS - TRUE
What are the two different classifications of manways on towers? - ANS - INTERNAL
- EXTERNAL
Which exchanger head is always absent on a u-tube bundle? - ANS FLOATING HEAD
A pipe union has a flow direction. - ANS - TRUE
To properly install an exchanger head and make sure the gasket seats properly you should: - ANS Glue gasket to the proper gasket surface, where the gasket will catch ou that gasket surface preventing it from rolling
By order of hitch strength, which is the correct order (strongest to weakest) - ANS Basket, vertical, choke