Weekly. Fuel-oil transfer shall be conducted under the ____ supervision of a P-98 COF holder. - Correct Answer-General. Fuel-oil system testing shall be conducted under the ____ supervision of a P-98 COF holder. - Correct Answer-Personal. The P-98 COF is required for any building in which fuel is transferred from the lowest floor to tanks on ____. - Correct Answer-Upper floors. Where is fuel-oil stored? - Correct Answer-Storage tank. The storage tank provides the supply of oil for ____ in the oil burner. - Correct Answer-
Combustion. No. ____ fuel-oil is thin, light and easily pumped through the system. - Correct Answer-2 The storage tank is located inside a ____ which will contain the oil in case of a leak. - Correct Answer-Dike. A ____ pump circulates oil throughout the system. - Correct Answer-Suction. What is present in fuel-oil coming from the storage tank? - Correct Answer-
Dirt/sediment. The ____ removes most dirt and sediment in oil coming from the storage tank before it reaches the burner. - Correct Answer-Strainer/filter. P-98 / Supervise Fuel-Oil Transfer In Buildings Exam Questions With Correct Answers, Latest Updated 2024/2025 (VERIFIED ANSWERS) How far from the bottom of the tank must the suction line be to avoid absorption of dirt and sediment? - Correct Answer-6 inches. Which device measures pressure below atmospheric pressure? - Correct Answer-
Vacuum gauge. What do excessive vacuum readings indicate? - Correct Answer-An obstruction in the suction line. Closing the shut-off valve does what? - Correct Answer-Stops the flow of oil for the purpose of cleaning the strainer and maintenance. The shut-off valve is located as close as possible to the burner to reduce the amount of oil remaining in the ____ after an emergency shutdown. - Correct Answer-Burner line. The main fuel valve is electrically operated and will open or close the line leading to the ____ of the oil burner. - Correct Answer-Atomizer. The main oil burner/combustion controller is the ____. It will shut down when no flame is detected. - Correct Answer-Primary relay control. Oil circulates through the system back to the storage tank through the ____. - Correct Answer-Oil return line. Which valve is provided for safety if the pressure becomes too great? - Correct Answer-
Back pressure relief valve. Day tanks may be located throughout the building above the ____ floor. - Correct Answer-Lowest. A separate ____ is required for each day tank to supply each floor. - Correct Answer-
Pump. What is provided in the system in case there is a leak in the piping? - Correct Answer-A leak collector. The leak collector is stored by the ____. - Correct Answer-Storage tank. The leak collector has an ____ gauge. - Correct Answer-Oil level. What will the main fuel valve do if there is a failure of ignition or combustion? - Correct Answer-It will shut down the burner system. The oil level gauge will show how much fuel oil is inside the ____. - Correct Answer-
Storage tank/day tank.