During an inspection of a gas dryer, you observe no exhaust vent. Your report
should:
A. Recommend installing a metal dryer duct vented to the exterior.
B. Recommend installing a flexible plastic dryer duct vented to the exterior.
1
, National Home Inspector Exam (NHIE) Whole House Practice Quiz
C. Indicate a code violation and state that corrective action should be taken.
D. Indicate that this is not a problem. - Answer: A) Recommend installing a metal
dryer duct vented to the exterior.
A collar tie is found in:
A. the attic near the top plate
B. the basement between floor joists
C. a wall at the intersection of two walls
D. the upper third of the rafter length - Answer: D. the upper third of the rafter
length
A claims made, errors and omissions insurance policy includes claims filed
A. during the time the policy is in effect.
B. after the policy has elapsed.
C. prior to the effective date.
D. while the inspector maintains any required licensing. - Answer: A. during the
time the policy is in effect.
On a previous work day, you left the cover off of the access to the crawl space. A
person fell the next day and was injured. Which of the following insurance types
will be used to pay damages?
A. Bonding.
2
, National Home Inspector Exam (NHIE) Whole House Practice Quiz
B. General liability
C. Errors and omissions and broker liability
D. Claims made and occurrence - Answer: B. General liability
A home inspection agreement is most likely to be interpreted using which law?
A. Federal
B. State
C. County
D. Parish - Answer: B. State
While inspecting a heat pump in the cooling mode, you measure a 28 degree F
differential between the interior supply and return air. When the ambient outdoor
conditions are 92 degrees and 50% humidity, you should suspect
A. the outdoor fan running too slowly.
B. an over heating compressor.
C. a dirty air handler filter.
D. thermostat set too low. - Answer: C. a dirty air handler filter.
When measuring the temperature differential between supply air and return air in
a central air conditioning system, on a humid summer day the difference should
be
A. 5 degree F and 15 degrees F.
3