100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

IRC Building Code Questions and Answers Already Passed

Rating
-
Sold
-
Pages
47
Grade
A+
Uploaded on
22-12-2023
Written in
2023/2024

IRC Building Code Questions and Answers Already Passed In Seismic Design Categories D0, D1, and D2, _____ stone masonry walls shall not be used. Rubble R404.1.1.1 Masonry foundation walls. In Seismic Design Categories Do, D1 and D2, foundations with stem walls shall be provided with a minimum of one No. ___ bar within 12 inches of the top of the wall and one No. ___ bar located 3 to 4 inches from the bottom of the footing. #4 #4 R403.1.3.1 Foundations with stemwalls The grade away from foundation walls shall fall a minimum of ___ inches within the first ____ feet. 6 in. 10 ft. (Read exception) R401.3 Drainage In flood hazard areas, enclosed areas below the design flood elevation shall be used sole for: 1._____ 2._____ 3._____ Parking of vehicles Building access or Storage R322.3.5 Enclosed areas below design flood elevation. Address number shall be a minimum of ___ inches high with a minimum stroke of ____inch. 4 in. 1/2 in. R319.1 Address numbers Protection of wood and wood based products from ___ shall be provided by the use of naturally durable wood or wood that is preservative treated. Decay R317.1 Location required Dwelling Units in two-family dwellings shall be separated from each other by wall and/or floor assemblies having not less than ___-hour fire resistive rating. 1 hour R302.3 Two family dwellings In areas where the probability of termite infestation is "very heavy", the clearance between foam plastics installed above grade and exposed earth shall be at least ____ inches. 6 in. R318.4 Foam plastic protection A thermal barrier is not required for foam plastic insulation in an attic that is entered only for purposes of ____ or ____. Repairs or maintenance R316.5.3 Attics Foam plastic shall be separated from the interior of a building by an approved ____ ____ of minimum ____- inch gypsum wallboard. Thermal barrier 1/2 in. R316.4 Thermal barrier All exterior footings shall be placed at least ___ inches below the undisturbed ground surface. 12 in. (Where applicable, the dept of footings shall also conform to R403.1.4.1 - R403.1.4.2) R403.1.4 Minimum length The top surface of footings shall be level. The bottom surface of footings shall not have a slope exceeding ____ unit vertical in ____ units horizontal. 1:10 R403.1.5 Slope Wood sill plates shall be anchored to the foundation with anchor bolts spaced a maximum of ____ feet on center. 6 ft. R403.1.6 Foundation anchorage Foundation anchor bolts shall be at least ___ inch in diameter and shall extend a minimum of ___ inches into the concrete or grouted cells of concrete masonry units. 1/2 in. 7 in. R403.1.6 Foundation

Show more Read less
Institution
IRC Building Code
Course
IRC Building Code











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
IRC Building Code
Course
IRC Building Code

Document information

Uploaded on
December 22, 2023
Number of pages
47
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

IRC Building Code Questions and Answers Already Passed In Seismic Design Categories D0, D1, and D2, _____ stone masonry walls shall not be used. ✔✔Rubble R404.1.1.1 Masonry foundation walls. In Seismic Design Categories Do, D1 and D2, foundations with stem walls shall be provided with a minimum of one No. ___ bar within 12 inches of the top of the wall and one No. ___ bar located 3 to 4 inches from the bottom of the footing. ✔✔#4 #4 R403.1.3. 1 Foundations with stemwalls The grade away from foundation walls shall fall a minimum of ___ inches within the first ____ feet. ✔✔6 in. 10 ft. (Read exception) R401.3 Drainage In flood hazard areas, enclosed areas below the design flood elevation shall be used sole for: 1._____ 2._____ 3._____ ✔✔Parking of vehicles Building access or Storage R322.3.5 Enclosed areas below design flood elevation. Address number shall be a minimum of ___ inches high with a minimum stroke of ____inch. ✔✔4 in. 1/2 in. R319.1 Address numbers Protection of wood and wood based products from ___ shall be provided by the use of naturally durable wood or wood that is preservative treated. ✔✔Decay R317.1 Location required Dwelling Units in two -family dwellings shall be sepa rated from each other by wall and/or floor assemblies having not less than ___ -hour fire resistive rating. ✔✔1 hour R302.3 Two family dwellings In areas where the probability of termite infestation is "very heavy", the clearance between foam plastics ins talled above grade and exposed earth shall be at least ____ inches. ✔✔6 in. R318.4 Foam plastic protection A thermal barrier is not required for foam plastic insulation in an attic that is entered only for purposes of ____ or ____. ✔✔Repairs or maintenan ce R316.5.3 Attics Foam plastic shall be separated from the interior of a building by an approved ____ ____ of minimum ____ - inch gypsum wallboard. ✔✔Thermal barrier 1/2 in. R316.4 Thermal barrier All exterior footings shall be placed at least ___ inch es below the undisturbed ground surface. ✔✔12 in. (Where applicable, the dept of footings shall also conform to R403.1.4.1 - R403.1.4.2) R403.1.4 Minimum length The top surface of footings shall be level. The bottom surface of footings shall not have a s lope exceeding ____ unit vertical in ____ units horizontal. ✔✔1:10 R403.1.5 Slope Wood sill plates shall be anchored to the foundation with anchor bolts spaced a maximum of ____ feet on center. ✔✔6 ft.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
StellarScores Western Governers University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1897
Member since
2 year
Number of followers
864
Documents
21000
Last sold
16 hours ago
Your Academic Hub: Documents, Study Guides, Summaries, Essays, and Exclusive Package Deals.

Welcome to my comprehensive academic resource store! At my online hub, I offer a vast array of meticulously crafted documents, study guides, summaries, and essays to support your educational journey. I understand the value of accuracy and completeness, which is why all my materials are verified and kept up-to-date with the latest versions. But that's not all! I also offer exclusive package deals and bundles to provide you with cost-effective solutions for your academic needs. Whether you're a student looking for study aids or seeking in-depth knowledge, my store is your one-stop destination for reliable, top-quality materials that can propel your learning experience to new heights. Explore my offerings and unlock the keys to academic success today!

Read more Read less
4.0

434 reviews

5
234
4
78
3
60
2
24
1
38

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions