Manager Exam
,EEMUA 159 Tank Integrity Manager Exam
Question 1
An explanation confuses Responsibilities of the Tank Integrity Manager with Mechanical
Design and Construction Features. Which replacement statement restores their
respective focuses?
A. Alongside Responsibilities of the Tank Integrity Manager within Fundamentals and Scope of
EEMUA 159: Nozzles, manways, shell penetrations, drainage sumps, and anti-rotation devices;
Mechanical Design and Construction Features: Nozzles, manways, shell penetrations, drainage
sumps, and anti-rotation devices
B. Alongside Responsibilities of the Tank Integrity Manager within Fundamentals and Scope of
EEMUA 159: Nozzles, manways, shell penetrations, drainage sumps, and anti-rotation devices;
Mechanical Design and Construction Features: inspection engineers, operators and competent
authorities
C. Alongside Responsibilities of the Tank Integrity Manager within Fundamentals and Scope of
EEMUA 159: inspection engineers, operators and competent authorities; Mechanical Design and
Construction Features: Nozzles, manways, shell penetrations, drainage sumps, and anti-rotation
devices
D. Alongside Responsibilities of the Tank Integrity Manager within Fundamentals and Scope of
EEMUA 159: inspection engineers, operators and competent authorities; Mechanical Design and
Construction Features: inspection engineers, operators and competent authorities
Correct Answer: C
Full Explanation: Responsibilities of the Tank Integrity Manager is considered together with
inspection engineers, operators and competent authorities in Fundamentals and Scope of EEMUA
159. Nozzles, manways, shell penetrations, drainage sumps, and anti-rotation devices is a specific
concern within Mechanical Design and Construction Features. Keeping the two concerns attached
to their respective concepts avoids a mistaken interchange
18812 Page 2
,EEMUA 159 Tank Integrity Manager Exam
Question 2
When separating the specific concerns of Above ground vertical cylindrical
flat-bottomed storage tank anatomy and Roof types, which proposed pairing
interchanges those concerns?
A. Material selection for tank shells: plates, structural sections and welding consumables
B. Mechanical Design and Construction Features: Nozzles, manways, shell penetrations, drainage
sumps, and anti-rotation devices
C. Above ground vertical cylindrical flat-bottomed storage tank anatomy: fixed roofs (cone,
dome, self-supporting), floating roofs (internal floating roofs - IFRs, external floating roofs - EFRs),
and domed external floating roofs
D. Structural stability wind girders: top wind rings, shell support systems and foundation
interfaces (ringwall, asphalt pads, compacted sand foundations)
Correct Answer: C
Full Explanation: Above ground vertical cylindrical flat-bottomed storage tank anatomy concerns
shell courses, bottom plates, and roof structures. Roof types concerns fixed roofs (cone, dome,
self-supporting), floating roofs (internal floating roofs - IFRs, external floating roofs - EFRs), and
domed external floating roofs. Assigning the concern of Roof types to Above ground vertical
cylindrical flat-bottomed storage tank anatomy interchanges their technical emphases
18812 Page 3
, EEMUA 159 Tank Integrity Manager Exam
Question 3
Which pairing gives an appropriate technical interpretation of both Material selection
for tank shells and Bottom Plate Inspection?
A. Alongside Material selection for tank shells within Metallurgy, Materials, and Fabrication:
plates, structural sections and welding consumables; Bottom Plate Inspection: Magnetic Flux
Leakage (MFL) testing for corrosion mapping, vacuum box testing of weld seams, ultrasonic
testing, and acoustic emission testing
B. Alongside Material selection for tank shells within Metallurgy, Materials, and Fabrication:
Magnetic Flux Leakage (MFL) testing for corrosion mapping, vacuum box testing of weld seams,
ultrasonic testing, and acoustic emission testing; Bottom Plate Inspection: Magnetic Flux Leakage
(MFL) testing for corrosion mapping, vacuum box testing of weld seams, ultrasonic testing, and
acoustic emission testing
C. Alongside Material selection for tank shells within Metallurgy, Materials, and Fabrication:
Magnetic Flux Leakage (MFL) testing for corrosion mapping, vacuum box testing of weld seams,
ultrasonic testing, and acoustic emission testing; Bottom Plate Inspection: plates, structural
sections and welding consumables
D. Alongside Material selection for tank shells within Metallurgy, Materials, and Fabrication:
plates, structural sections and welding consumables; Bottom Plate Inspection: plates, structural
sections and welding consumables
Correct Answer: A
Full Explanation: Material selection for tank shells is considered together with plates, structural
sections and welding consumables in Metallurgy, Materials, and Fabrication. Bottom Plate
Inspection concerns Magnetic Flux Leakage (MFL) testing for corrosion mapping, vacuum box
testing of weld seams, ultrasonic testing, and acoustic emission testing. Keeping the two concerns
attached to their respective concepts avoids a mistaken interchange
18812 Page 4