CSWIP Ultrasonic Testing
Level 2 Examination Exam
,18625 QUESTIONS
Question 1
A review separates evidence about phased array probe basics (element pitch,
frequency, and aperture) from evidence about principles of phased array
generation, electronic scanning, and dynamic depth focusing (TFM/FMC). Which
pair of labels fits?
A. Phased Array Ultrasonic Testing (PAUT); then Piezoelectric Transducers (Probes)
B. Piezoelectric Transducers (Probes); then Ultrasonic Flaw Detector Operation
C. Piezoelectric Transducers (Probes); then Phased Array Ultrasonic Testing (PAUT)
D. Ultrasonic Flaw Detector Operation; then Phased Array Ultrasonic Testing (PAUT)
Correct Answer: C
Full Explanation:
Piezoelectric Transducers (Probes) addresses phased array probe basics (element pitch, frequency,
and aperture). Phased Array Ultrasonic Testing (PAUT) addresses principles of phased array
generation, electronic scanning, and dynamic depth focusing (TFM/FMC). Keeping these associations
intact distinguishes the two concerns; swapping them or substituting DAC (Distance Amplitude
Correction) curves and AVG/DGS curves construction and usage changes the technical focus.
Question 2
A reviewer must avoid interchanging Piezoelectric Transducers (Probes) and
Ultrasonic Flaw Detector Operation. Which allocation is sound?
A. Piezoelectric Transducers (Probes): Phased array probe basics (element pitch, frequency, and
aperture); Ultrasonic Flaw Detector Operation: Verifying probe index point, beam angle,
time-base linearity, and amplifier accuracy
B. Piezoelectric Transducers (Probes): DAC (Distance Amplitude Correction) curves and AVG/DGS
curves construction and usage; Ultrasonic Flaw Detector Operation: Phased array probe
basics (element pitch, frequency, and aperture)
C. Piezoelectric Transducers (Probes): Phased array probe basics (element pitch, frequency, and
aperture); Ultrasonic Flaw Detector Operation: DAC (Distance Amplitude Correction) curves
and AVG/DGS curves construction and usage
D. Piezoelectric Transducers (Probes): Verifying probe index point, beam angle, time-base
linearity, and amplifier accuracy; Ultrasonic Flaw Detector Operation: DAC (Distance
Amplitude Correction) curves and AVG/DGS curves construction and usage
Correct Answer: C
Full Explanation:
Piezoelectric Transducers (Probes) addresses phased array probe basics (element pitch, frequency,
and aperture). Ultrasonic Flaw Detector Operation addresses DAC (Distance Amplitude Correction)
curves and AVG/DGS curves construction and usage. Keeping these associations intact distinguishes
the two concerns; swapping them or substituting verifying probe index point, beam angle, time-base
linearity, and amplifier accuracy changes the technical focus.
2
,18625 QUESTIONS
Question 3
Which ordered pair correctly distinguishes a concern involving
distance-Amplitude Correction (DAC) setup for weld examinations from one
involving application of BS EN ISO standards (e.g., ISO 11666, ISO 23279, ISO
17640)?
A. Weld Inspection Methodologies (BS EN ISO 17640 / ASME Sec V); then International Standards
and Codes
B. Forgings and Castings Inspection; then International Standards and Codes
C. International Standards and Codes; then Weld Inspection Methodologies (BS EN ISO 17640 /
ASME Sec V)
D. Weld Inspection Methodologies (BS EN ISO 17640 / ASME Sec V); then Forgings and Castings
Inspection
Correct Answer: A
Full Explanation:
Weld Inspection Methodologies (BS EN ISO 17640 / ASME Sec V) addresses distance-Amplitude
Correction (DAC) setup for weld examinations. International Standards and Codes addresses
application of BS EN ISO standards (e.g., ISO 11666, ISO 23279, ISO 17640). Keeping these
associations intact distinguishes the two concerns; swapping them or substituting managing grain
size, acoustic anisotropy, and scattering in coarse-grained castings changes the technical focus.
Question 4
Which technical association needs correction when distinguishing International
Standards and Codes from Physics of Ultrasound?
A. International Standards and Codes: Wave propagation theory and acoustic particle
displacement
B. Mechanisms of ultrasonic attenuation: absorption and scattering
C. Weld Inspection Methodologies (BS EN ISO 17640 / ASME Sec V): Selection of correct probe
angles ($45^\circ$, $60^\circ$, $70^\circ$) based on plate thickness and weld geometry
D. Flaw Detection and Characterization: Estimating defect length, height, through-wall extent,
and depth location
Correct Answer: A
Full Explanation:
Wave propagation theory and acoustic particle displacement is associated with Physics of Ultrasound,
rather than the specific focus of International Standards and Codes. International Standards and
Codes addresses application of BS EN ISO standards (e.g., ISO 11666, ISO 23279, ISO 17640). The
other entries keep each concern with its own technical area.
3
, 18625 QUESTIONS
Question 5
Two task cards cover Physics of Ultrasound and Piezoelectric Transducers
(Probes). Which set of descriptions matches both cards?
A. Physics of Ultrasound: Acoustic impedance ($Z$), reflection coefficients, and transmission
coefficients at normal incidence; Piezoelectric Transducers (Probes): Normal beam (straight
beam) probes and angle beam probes (shear wave wedges)
B. Physics of Ultrasound: Acoustic impedance ($Z$), reflection coefficients, and transmission
coefficients at normal incidence; Piezoelectric Transducers (Probes): Near field (Fresnel zone)
and far field (Fraunhofer zone) calculations
C. Physics of Ultrasound: Near field (Fresnel zone) and far field (Fraunhofer zone) calculations;
Piezoelectric Transducers (Probes): Normal beam (straight beam) probes and angle beam
probes (shear wave wedges)
D. Physics of Ultrasound: Normal beam (straight beam) probes and angle beam probes (shear
wave wedges); Piezoelectric Transducers (Probes): Acoustic impedance ($Z$), reflection
coefficients, and transmission coefficients at normal incidence
Correct Answer: A
Full Explanation:
Physics of Ultrasound addresses acoustic impedance ($Z$), reflection coefficients, and transmission
coefficients at normal incidence. Piezoelectric Transducers (Probes) addresses normal beam (straight
beam) probes and angle beam probes (shear wave wedges). Keeping these associations intact
distinguishes the two concerns; swapping them or substituting near field (Fresnel zone) and far field
(Fraunhofer zone) calculations changes the technical focus.
Question 6
Which set keeps the review of Ultrasonic Flaw Detector Operation internally
consistent?
A. Electronic pulse generators; receivers; amplifiers
B. Electronic pulse generators; receivers; time-base linearity
C. Electronic pulse generators; receivers; beam angle
D. Electronic pulse generators; receivers; working principles
Correct Answer: A
Full Explanation:
The coherent group is Electronic pulse generators; receivers; amplifiers. These concerns belong
together within Ultrasonic Flaw Detector Operation. Each other group replaces one relevant concern
with an item from a different focus.
4