(BSI) ENERGY STAR Single
Family Exam
,QUESTIONS
Question 1
When Roles and responsibilities of builders, raters, and Home Certification Organizations (HCO) is
the task, which allocation avoids substituting National Rater Design Review Checklist for
Introduction to the ENERGY STAR Single-Family Program?
A. National Rater Design Review Checklist: Roles and responsibilities of builders, raters, and Home
Certification Organizations (HCO)
B. Introduction to the ENERGY STAR Single-Family Program: Roles and responsibilities of builders,
raters, and Home Certification Organizations (HCO)
C. Introduction to the ENERGY STAR Single-Family Program: Verification of high-performance
fenestration and insulation levels
D. National Rater Design Review Checklist: Software modeling inputs, compliance margins, and
passing criteria relative to reference home designs
Correct Answer: B
Full Explanation:
Introduction to the ENERGY STAR Single-Family Program addresses Roles and responsibilities of
builders, raters, and Home Certification Organizations (HCO). The separate focus of National Rater
Design Review Checklist is Verification of high-performance fenestration and insulation levels. An
assignment must reflect the intended task, rather than transfer a different activity into its place.
Question 2
Which comparison correctly distinguishes "Verification of ventilation airflow using balometers or
flow hoods" from "Program scope, eligibility criteria, and compliance pathways (National and
Regional Program Requirements)"?
A. First: National Rater Design Review Checklist; second: Indoor Air Quality (IAQ) and Ventilation
Systems
B. First: Introduction to the ENERGY STAR Single-Family Program; second: Field Testing, Verifications,
and Quality Assurance
C. First: Indoor Air Quality (IAQ) and Ventilation Systems; second: National Rater Design Review
Checklist
D. First: Field Testing, Verifications, and Quality Assurance; second: Introduction to the ENERGY STAR
Single-Family Program
Correct Answer: D
Full Explanation:
Field Testing, Verifications, and Quality Assurance includes Verification of ventilation airflow using
balometers or flow hoods. Introduction to the ENERGY STAR Single-Family Program includes Program
scope, eligibility criteria, and compliance pathways (National and Regional Program Requirements).
The comparison maintains the specific focus of each activity.
2
,QUESTIONS
Question 3
A reviewer separates Energy Rating Index (ERI) and Performance Target Procedures from
Introduction to the ENERGY STAR Single-Family Program. Which description maintains that
distinction for Understanding the ERI Target Procedure and target score calculations?
A. Energy Rating Index (ERI) and Performance Target Procedures: Understanding the ERI Target
Procedure and target score calculations
B. Introduction to the ENERGY STAR Single-Family Program: Understanding the ERI Target Procedure
and target score calculations
C. Energy Rating Index (ERI) and Performance Target Procedures: Roles and responsibilities of
builders, raters, and Home Certification Organizations (HCO)
D. Introduction to the ENERGY STAR Single-Family Program: HVAC Design Documentation: Review of
National HVAC Design Reports, load calculations, and outdoor design temperature limitations
Correct Answer: A
Full Explanation:
Energy Rating Index (ERI) and Performance Target Procedures addresses Understanding the ERI
Target Procedure and target score calculations. The separate focus of Introduction to the ENERGY
STAR Single-Family Program is Roles and responsibilities of builders, raters, and Home Certification
Organizations (HCO). An assignment must reflect the intended task, rather than transfer a different
activity into its place.
Question 4
Which comparison correctly distinguishes "Fully-Aligned Air Barriers: Continuity of air barriers at
exterior vertical surfaces, knee walls, shafts, and cantilevers" from "Verification of ventilation
airflow using balometers or flow hoods"?
A. First: Thermal Enclosure System Rater Field Checklist; second: Field Testing, Verifications, and
Quality Assurance
B. First: Indoor Air Quality (IAQ) and Ventilation Systems; second: National Rater Design Review
Checklist
C. First: National Rater Design Review Checklist; second: Indoor Air Quality (IAQ) and Ventilation
Systems
D. First: Field Testing, Verifications, and Quality Assurance; second: Thermal Enclosure System Rater
Field Checklist
Correct Answer: A
Full Explanation:
Thermal Enclosure System Rater Field Checklist includes Fully-Aligned Air Barriers: Continuity of air
barriers at exterior vertical surfaces, knee walls, shafts, and cantilevers. Field Testing, Verifications,
and Quality Assurance includes Verification of ventilation airflow using balometers or flow hoods. The
comparison maintains the specific focus of each activity.
3
, QUESTIONS
Question 5
A reviewer separates Introduction to the ENERGY STAR Single-Family Program from Field Testing,
Verifications, and Quality Assurance. Which description maintains that distinction for Overview of
EPA ENERGY STAR Residential New Construction programs?
A. Introduction to the ENERGY STAR Single-Family Program: Duct blaster testing (total and outdoor
duct leakage measurements)
B. Field Testing, Verifications, and Quality Assurance: Review of mass, orientation, and thermal
enclosure details prior to construction
C. Field Testing, Verifications, and Quality Assurance: Overview of EPA ENERGY STAR Residential
New Construction programs
D. Introduction to the ENERGY STAR Single-Family Program: Overview of EPA ENERGY STAR
Residential New Construction programs
Correct Answer: D
Full Explanation:
Introduction to the ENERGY STAR Single-Family Program addresses Overview of EPA ENERGY STAR
Residential New Construction programs. The separate focus of Field Testing, Verifications, and Quality
Assurance is Duct blaster testing (total and outdoor duct leakage measurements). An assignment
must reflect the intended task, rather than transfer a different activity into its place.
Question 6
Which pairing correctly links a technical focus to its associated activity when distinguishing Energy
Rating Index (ERI) and Performance Target Procedures from Introduction to the ENERGY STAR
Single-Family Program?
A. Introduction to the ENERGY STAR Single-Family Program: Software modeling inputs, compliance
margins, and passing criteria relative to reference home designs
B. Energy Rating Index (ERI) and Performance Target Procedures: Software modeling inputs,
compliance margins, and passing criteria relative to reference home designs
C. Energy Rating Index (ERI) and Performance Target Procedures: Program scope, eligibility criteria,
and compliance pathways (National and Regional Program Requirements)
D. Indoor Air Quality (IAQ) and Ventilation Systems: Program scope, eligibility criteria, and
compliance pathways (National and Regional Program Requirements)
Correct Answer: B
Full Explanation:
Energy Rating Index (ERI) and Performance Target Procedures addresses Software modeling inputs,
compliance margins, and passing criteria relative to reference home designs. By comparison,
Introduction to the ENERGY STAR Single-Family Program addresses Program scope, eligibility criteria,
and compliance pathways (National and Regional Program Requirements). Keeping those associations
clear prevents one task from being substituted for the other
4