Capacity Calculation Exam Questions
and Answers with Explanations |
2026/2027 Updated Edition | Printable
PDF Download
Section 1: Septic Tank Sizing Fundamentals and Wastewater
Flow Estimation
Question 1
A residential septic system is being designed for a four-bedroom
home in Arkansas. The designer must determine the appropriate
septic tank capacity based on the expected wastewater flow and
applicable regulatory requirements. Which factor is most
fundamental when establishing the minimum required septic tank
capacity?
A. The total square footage of the house alone
B. The number of bathrooms without considering occupancy
C. The estimated daily wastewater flow and applicable minimum
tank capacity requirements
D. The depth of the soil absorption trench alone
Rationale: Septic tank sizing is primarily based on estimated daily
wastewater generation and the minimum capacity requirements
established by applicable regulations. Bedroom count is commonly
,used as a design indicator for residential wastewater flow. House
square footage, bathroom count, and absorption trench depth may
influence other aspects of system design, but they do not
independently determine the required septic tank volume. Proper
sizing provides adequate settling, solids storage, and wastewater
treatment capacity.
Question 2
A home has three bedrooms, and the applicable design standard
estimates wastewater generation at 150 gallons per bedroom per
day. What is the estimated daily wastewater flow?
A. 300 gallons per day
B. 350 gallons per day
C. 450 gallons per day
D. 600 gallons per day
Rationale: The estimated daily wastewater flow is calculated by
multiplying the number of bedrooms by the design flow per
bedroom.
𝑄 = 3 × 150
𝑄 = 450 gallons/day
This estimate is used as a basis for septic system design. Actual
regulatory design flows may differ depending on the applicable
Arkansas requirements and the type of occupancy.
,Question 3
A septic tank is specified to have a nominal capacity of 1,000
gallons. Which statement best describes the meaning of this
nominal capacity?
A. It represents the total wastewater generated by the household
over one month.
B. It represents the tank's designated liquid storage volume
under the specified operating conditions.
C. It represents the maximum amount of sludge that may
accumulate before pumping.
D. It represents the total volume of wastewater that can pass
through the tank in one day.
Rationale: Nominal septic tank capacity generally refers to its
designated liquid capacity, rather than its daily treatment throughput
or sludge storage volume. The tank continuously receives
wastewater and discharges effluent while maintaining a liquid level.
Solids accumulate over time and reduce the effective available
volume. Pumping is necessary to restore adequate solids storage
and maintain treatment performance.
Question 4
A septic tank has internal dimensions of 8 feet long, 5 feet wide, and
5 feet of liquid depth. What is its approximate liquid capacity in
gallons?
A. 1,000 gallons
B. 1,200 gallons
, C. 1,496 gallons
D. 2,000 gallons
Rationale: The rectangular tank's liquid volume is calculated by
multiplying length, width, and liquid depth.
𝑉 = 8 × 5 × 5 = 200 ft3
One cubic foot contains approximately 7.4805 gallons.
200 × 7.4805 = 1,496.1 gallons
The approximate liquid capacity is 1,496 gallons. The calculation
assumes the tank has a rectangular interior and that the stated
depth is the liquid depth rather than the total structural depth.
Question 5
A septic tank has a total internal volume of 1,500 gallons. The
designer determines that 100 gallons must be reserved for the
space above the normal liquid level. What is the approximate liquid
capacity?
A. 1,400 gallons
B. 1,400 gallons
C. 1,500 gallons
D. 1,600 gallons
Rationale: If the total internal volume is 1,500 gallons and 100
gallons are allocated to non-liquid space above the operating liquid
level, the liquid capacity is calculated as follows.