power engineering practice exam
g8 g8 g8
Twog8canadadiang8codesg8whichg8haveg8beeng8adoptedg8byg8allg8canadiang8jur
isdictionsg8andg8whichg8areg8ofg8importanceg8tog8fifthg8classg8powerg8engineer
ingg8areg8the:g8-g8correctg8answer✔ ✔ CSAg8B51g8Andg8B52
Theg8ASMEg8codeg8sectionsg8whichg8areg8mostg8pertinentg8tog8Fifthg8andg8Fou
rthg8classg8powerg8engineerg8areg8sections:g8-g8correctg8answer✔ ✔
IVg8andg8VI
whatg8codeg8containsg8guidelinesg8forg8theg8careg8andg8operationg8ofg8heatingg8
boilers?g8-g8correctg8answer✔ ✔ ASMEg8Sectiong8VI
Wheng8ag8feedwaterg8pumpg8feedsg8twog8ofg8moreg8boilersg8fromg8ag8commong
8source,g8thereg8mustg8beg8ag8regulatingg8valveg8-g8correctg8answer✔ ✔
Eachg8feedwaterg8lineg8tog8eachg8boiler
whatg8determinesg8theg8classificationg8ofg8theg8certificateg8ofg8completencyg8r
equiredg8forg8theg8roleg8ofg8chiefg8powerg8engineer?g8-g8correctg8answer✔
✔ Kilowattg8ratingg8ofg8theg8powerplant
Theg8provincialg8regulationsg8requireg8thatg8allg8weldingg8repairsg8ong8boilersg
8mustg8be:g8-g8correctg8answer✔ ✔
approvedg8byg8ang8authorizedg8inspector
,Ag8boilerg8ing8whichg8steamg8isg8madeg8atg8ag8presentg8notg8greaterg8thang8103g8
Kilopascals,g8isg8properlyg8termedg8a:g8-g8correctg8answer✔ ✔
heatingg8plant
Ing8theg8powerg8engineersg8regulationsg8definitions,g8______g8meansg8anyg8pa
rtg8ofg8theg8surfaceg8ofg8ag8boilerg8thatg8isg8ing8contactg8withg8fluidg8underg8press
ureg8ong8oneg8sideg8andg8theg8productsg8ofg8combustiong8ong8theg8otherg8side:g8-
g8correctg8answer✔ ✔ Heatingg8surface
Heatingg8plantg8meansg8oneg8org8moreg8boilersg8ing8whichg8waterg8thatg8cang8b
eg8heatedg8pressureg8andg8temperatureg8ofg8notg8moreg8than:g8-
g8correctg8answer✔ ✔ 1,100g8kPag8andg8ag8tempg8ofg8121c
Theg8lettersg8CRNg8standsg8forg8-g8correctg8answer✔ ✔
Canadiang8registrationg8number
Heatg8passesg8throughg8theg8metalg8ofg8heatingg8surfacesg8by:g8-
g8correctg8answer✔ ✔ conduction
Sixg8kgg8wouldg8beg8ag8measureg8ofg8ang8object's:g8-g8correctg8answer✔ ✔
mass
, theg8termg8usedg8tog8describeg8theg8fluidg8tog8gasg8changeg8ofg8stateg8duringg8the
g8additiong8ofg8heatg8isg8latentg8heatg8of:g8-g8correctg8answer✔ ✔
evapotarion
theg8fahrenheitg8scaleg8considersg8theg8boilingg8pointg8ofg8waterg8tog8beg8-
g8correctg8answer✔ ✔ 212c
Theg8threeg8meathodsg8ofg8heatg8transferg8are:g8-g8correctg8answer✔ ✔
Radiation,g8conductiong8andg8convection
Waterg8extinguishesg8ag8fireg8by:g8-g8correctg8answer✔ ✔
coolingg8theg8combustibleg8material
Waterg8hammerg8cang8beg8preventedg8org8minimizedg8byg8installing___g8cha
mbersg8ong8ag8pipingg8system.g8-g8correctg8answer✔ ✔ "endg8ofg8line"g8air
wheng8workingg8belowg8groundg8level,g8theg8workg8presentsg8theg8dangerg8ofg8
:g8-g8correctg8answer✔ ✔ fallingg8objects
Underg8WHMISg8legislationg8allg8workersg8haveg8theg8rightg8tog8-
g8correctg8answer✔ ✔ Knowg8whatg8materialg8theyg8areg8workingg8with
g8 g8 g8
Twog8canadadiang8codesg8whichg8haveg8beeng8adoptedg8byg8allg8canadiang8jur
isdictionsg8andg8whichg8areg8ofg8importanceg8tog8fifthg8classg8powerg8engineer
ingg8areg8the:g8-g8correctg8answer✔ ✔ CSAg8B51g8Andg8B52
Theg8ASMEg8codeg8sectionsg8whichg8areg8mostg8pertinentg8tog8Fifthg8andg8Fou
rthg8classg8powerg8engineerg8areg8sections:g8-g8correctg8answer✔ ✔
IVg8andg8VI
whatg8codeg8containsg8guidelinesg8forg8theg8careg8andg8operationg8ofg8heatingg8
boilers?g8-g8correctg8answer✔ ✔ ASMEg8Sectiong8VI
Wheng8ag8feedwaterg8pumpg8feedsg8twog8ofg8moreg8boilersg8fromg8ag8commong
8source,g8thereg8mustg8beg8ag8regulatingg8valveg8-g8correctg8answer✔ ✔
Eachg8feedwaterg8lineg8tog8eachg8boiler
whatg8determinesg8theg8classificationg8ofg8theg8certificateg8ofg8completencyg8r
equiredg8forg8theg8roleg8ofg8chiefg8powerg8engineer?g8-g8correctg8answer✔
✔ Kilowattg8ratingg8ofg8theg8powerplant
Theg8provincialg8regulationsg8requireg8thatg8allg8weldingg8repairsg8ong8boilersg
8mustg8be:g8-g8correctg8answer✔ ✔
approvedg8byg8ang8authorizedg8inspector
,Ag8boilerg8ing8whichg8steamg8isg8madeg8atg8ag8presentg8notg8greaterg8thang8103g8
Kilopascals,g8isg8properlyg8termedg8a:g8-g8correctg8answer✔ ✔
heatingg8plant
Ing8theg8powerg8engineersg8regulationsg8definitions,g8______g8meansg8anyg8pa
rtg8ofg8theg8surfaceg8ofg8ag8boilerg8thatg8isg8ing8contactg8withg8fluidg8underg8press
ureg8ong8oneg8sideg8andg8theg8productsg8ofg8combustiong8ong8theg8otherg8side:g8-
g8correctg8answer✔ ✔ Heatingg8surface
Heatingg8plantg8meansg8oneg8org8moreg8boilersg8ing8whichg8waterg8thatg8cang8b
eg8heatedg8pressureg8andg8temperatureg8ofg8notg8moreg8than:g8-
g8correctg8answer✔ ✔ 1,100g8kPag8andg8ag8tempg8ofg8121c
Theg8lettersg8CRNg8standsg8forg8-g8correctg8answer✔ ✔
Canadiang8registrationg8number
Heatg8passesg8throughg8theg8metalg8ofg8heatingg8surfacesg8by:g8-
g8correctg8answer✔ ✔ conduction
Sixg8kgg8wouldg8beg8ag8measureg8ofg8ang8object's:g8-g8correctg8answer✔ ✔
mass
, theg8termg8usedg8tog8describeg8theg8fluidg8tog8gasg8changeg8ofg8stateg8duringg8the
g8additiong8ofg8heatg8isg8latentg8heatg8of:g8-g8correctg8answer✔ ✔
evapotarion
theg8fahrenheitg8scaleg8considersg8theg8boilingg8pointg8ofg8waterg8tog8beg8-
g8correctg8answer✔ ✔ 212c
Theg8threeg8meathodsg8ofg8heatg8transferg8are:g8-g8correctg8answer✔ ✔
Radiation,g8conductiong8andg8convection
Waterg8extinguishesg8ag8fireg8by:g8-g8correctg8answer✔ ✔
coolingg8theg8combustibleg8material
Waterg8hammerg8cang8beg8preventedg8org8minimizedg8byg8installing___g8cha
mbersg8ong8ag8pipingg8system.g8-g8correctg8answer✔ ✔ "endg8ofg8line"g8air
wheng8workingg8belowg8groundg8level,g8theg8workg8presentsg8theg8dangerg8ofg8
:g8-g8correctg8answer✔ ✔ fallingg8objects
Underg8WHMISg8legislationg8allg8workersg8haveg8theg8rightg8tog8-
g8correctg8answer✔ ✔ Knowg8whatg8materialg8theyg8areg8workingg8with