What formulas correctly describes the relationship between absorbance and %T? - ANS A=
2-log %T
A = log 1/T
A = -log T


A solution that has a transmittance of 1.0 would have an absorbance of.. - ANS 2.0


In absorption spectrophotometry... - ANS Absorbance is directly proportional to
transmittance


Which wavelength would be absorbed strongly by a red-colored solution? - ANS 450 nm


A green colored solution would show highest transmittance at... - ANS 525 nm


A tech is performing an enzyme assay at 340 nm using a visible-range spectrophotometer. After
setting the wavelength and sdjusting the readout to zero %T with the light path blocked, a
cuvette with deionized whater is inserted. With the light path fully open and the 100% T control
at maximum, the instrument readout will not rise about 90%T. What is the most appropriate
first course of action? - ANS Replace the source lamp




1 @COPYRIGHT 2025/2026 ALLRIGHTS RESERVED.

,Which type of monochromater produces the purest monochromatic light in the UV range? -
ANS A prism and variable exit slit


Which monochromator specification is required in order to measure the true absorbance of a
compound having a natural absorption bandwidth of 30 nm? - ANS 5-nm bandpass


Which photodetector is most sensitive to low levels of light? - ANS Photomultiplier tube


Which condition is a common cause of stray light? - ANS Dispersion from second-order
spectra


What is the most common cause of loss of linearity at high-analyte concentrations? -
ANS Stray light


Which type of filteris best for measuring stray light? - ANS Sharp cutoff


Which of the following materials is best suited for verifying the wavelength calibration of a
spectrophotometer? - ANS Holmium oxide glass


Why do many optical systems in chemistry analyzers utilize a reference light path? - ANS To
minimize error caused by source lamp fluctuation


Which component is required in a spectrophotometer in order to produce a spectral
absorbance curve? - ANS Photodiode array


The half-band width of a monochromator is defined by - ANS the range of the wavelengths
passed at 50% transmittance


The reagent blank corrects for absorbance caused by - ANS the color of reagents




2 @COPYRIGHT 2025/2026 ALLRIGHTS RESERVED.

,A plasma sample is hemolyzed and turbid. What is required to perform a sample blank in order
to correct the measurement for the intrinsic absorbance of the sample when performing a
spectrophotometric assay? - ANS Substitute saline for the reagent


Which instrument requires a highly regulared DC power supply? - ANS A spectrophotometer
with a photomultiplier tube


Which statement regarding reflectometry is true? - ANS 100% reflectance is set with an
opaque film called a white reference


Bichromatic measurement of absorbance can correct for interfering substances if - ANS The
concentration of the interferent to absorbance is the same at both wavelengths


Which instrument requires a primary and secondary monochromator? - ANS Fluorometer


Which of the following statements about fluorometry is accurate? - ANS Unsaturated cyclic
molecules are often fluorescent


Which of the following components is not needed in a chemiluminescent immunoassay
analyzer? - ANS Source lamp


Which substance is used to generate the light signal in electochemiluminescence? -
ANS Ruthenium


Light scattering when the wavelength is greater than 10 times the particle diameter is described
by - ANS Rayleigh's law


Which statement regarding nephelometry is true? - ANS The detector response is directly
proportional to concentration


The purpose of the nebulizer in an atomic absorption spectrophotometer that uses a flame is to
- ANS convert ions to atoms
3 @COPYRIGHT 2025/2026 ALLRIGHTS RESERVED.

, A flameless atomic absorption spectrophotometer dhydrates and atomizes a sample using -
ANS A graphite capillary furnace


When measuring lead in whole blood using atomic absorption spectrophotometry, what
reagent is required to obtain the needed sensitivity and precision? - ANS triton-X-100


Interference in atomic absorption spectrophotometery caused by differences in viscosity is
called - ANS Matrix effect


All of the following are required when measuring magnesium by atomic absorption
spectrophotometry except - ANS A 285 nm reference beam to correct for background
absorption


When measuring calcium by atomic absorption spectrophotometry, which is required -
ANS Lanthanum oxide to chelate phosphates


Ion selective analyzers using undiluted samples have what advantage over analyzers that use a
diluted sample - ANS Are not subject to pseudohyponatremia caused by high lipids


Select the equation describing the potential that develops at the surface of an ion-selective
electrode is determined by the - ANS Concentration of the potassium chloride filling solution


The term RT/nF in the Nernst equation defines the Slope of the electrode -
ANS Concentration of the potassium chloride filling solution


The ion-selective membrane used tho measure potassium is made of - ANS Valinomycin gel


The response of a sodium electrode to a to-fold increase in sodium concentration should be -
ANS An increase in potential of approximately 60 mV




4 @COPYRIGHT 2025/2026 ALLRIGHTS RESERVED.

Written for

Institution
MEDICAL LABORATORY SCIENCE
Course
MEDICAL LABORATORY SCIENCE

Document information

Uploaded on
January 5, 2026
Number of pages
137
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheStar Florida State University
View profile
Follow You need to be logged in order to follow users or courses
Sold
622
Member since
2 year
Number of followers
180
Documents
24417
Last sold
18 hours ago
Stuvia Prodigy

Tested, Verified and Updated Study Materials with 100% Guaranteed Success.

3.8

124 reviews

5
58
4
22
3
23
2
4
1
17

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions