Practical Experience Record
Record of Experience
Unit 5.1a: Extraction Procedure
Range
Simple Extraction
Patient Type
*Select a patient type from the options below*
Procedure Carried Out
Guidance Notes:
● Learners should state the procedure to be carried out.
● Learners should state how the area was prepared, the equipment
switched on, the safety and PPE requirements considered, and
how they assisted the clinician and the patient during the
procedure.
● Learners should describe the patient on which the treatment was
carried out
, Exemplar work only
Preparing and Maintaining the clinical area for Simple Extraction procedure- Permanent
Upper Left 4
Patient Details: Male Child
Regular Patient
Date of birth: xx/xx/xxxx
Medical History: Clear
Clinical Area: mixed dental practice
I changed into my uniform, wore the correct footwear and tucked my hijab into my shirt. Made
sure I wasn't wearing jewelry & my nails were short.
Throughout the day I followed the HTM 01-05 standards to decrease the risk of infection.
Washed my hands using the six step hand hygiene technique provided by the NHS to reduce
cross-infection. I must also close the sink with my elbow to avoid dirty hand contamination. I
made sure to wash my hands after each of the following instances: after touching a patient’s
surroundings, after touching a patient, after exposure to body fluid, after undertaking a clinical
procedure and after touching a patient. This is in accordance to HTM105.
I put on my personal protective equipment which consists of single use: visor, examination
gloves, face mask and apron.
I switched on the compressor & dental units for the surgery and made sure all equipment I
needed for the day was ready for use, this includes: computer, x-ray machine and dental chair
(chair, light and aspiration equipment). While doing this, I checked if they were in good
working condition by visually checking if their lights turn on and I test ran them.
No disposable covers are used in my practice, but, I know this is considered a best practice
requirement.
I rinsed both spittoon filters that were left to sit in sterilizing fluid overnight, and I placed them
back into the side of the spittoon and the sink of the spittoon.
I then use disinfectant antimicrobial wipes to wipe down all surfaces while checking for any
visible faults. surfaces while checking for any visible faults. Surfaces include: cupboards, table
tops, dental chair and equipment on table tops.
I checked if there is enough biocide solution for dental waterlines and ultrasonic scaler
machine, the biocide solution (10ml of biocide per 990ml of demineralised water). should be