▶ T/F: Tees are allowed for inlet and outlet devices. Answer: T

▶ T/F: An inlet line should be at least 3 inches above the liquid level..
Answer: T

▶ T/F: A leakage from the tank or joints of 1.6 gallons/hour is permissible.
Answer: F

▶ T/F: A 12-inch port (minimum) must be provided in the top of the tank.
Answer: T

▶ T/F: The first compartment should be smaller than the second
compartment. Answer: F....Should be 1/2 to 2/3s the second

▶ T/F: Outlet Tee should extend to the bottom of the tank. Answer: F

▶ T/F: The tank must be level. Answer: T

▶ T/F: A minimum 4-inch-thick sand, sandy loam, clay loam, or pea gravel
pad is required under prefabricated tanks. Answer: T

▶ The standard drainfield depth in East and Central Texas is limited to.
Answer: 18 inches minimum and 36 inches maximum

▶ The minimum distance between standard drainfield excavations is.
Answer: 3 feet

▶ Grease interceptors are needed. Answer: on wastewater lines from
commercial kitchens

▶ Which of the following is true if porous media in a standard drainfield?.
Answer: It should be uniform in size, it should be 0.75 inch to 2 inches in
size, it should be clean and resistant to breakdown

,▶ A standard drainfield excavation should. Answer: be level within 1 inch
per 25 feet or a maximum of 3 inches whichever is less

▶ A standard perforated drainline should be which of the following?.
Answer: 3 inches to 4 inches in diameter, a maximum length of 150 feet,
laid parallel in multiple-line system

▶ The purpose of the geotextile fabric over gravel is to. Answer: prevent
backfill from entering porous media

▶ A pumped effluent drainfield. Answer: is an alternative for well-drained
clay soils on nearly level sites, has a 2% or less slope for single-family
dwellings only

▶ Which of the following must be known prior to actually laying out a new
OSSF?. Answer: building location, size of the property, soil conditions in
the drainfield

▶ In an unlined ET system, wastewater is disposed of by which of the
following?. Answer: evaporation, transpiration, soil absorption

▶ A gravelless pipe drainfield. Answer: can be backfilled with Class Ib, II,
or III soil

▶ A leaching chamber system. Answer: requires 25% less absorptive area
than a standard system for new construction

▶ Aerobic treatment units. Answer: utilize aerobic bacteria and oxygen to
break down complex organics and produce carbon dioxide

▶ To determine if a proprietary aerobic treatment unit is appropriate for use
with surface application disposal it must. Answer: be on the TCEQ's most
recently approved list

▶ To determine the minimum size of aerobic treatment unit needed for a
particular home, one must know. Answer: number of bedrooms and square
feet in the home and refer to TCEQ Table II

,▶ Which of the following is a likely cause of a "rotten egg" odor from an
aerobic treatment plant?. Answer: Mechanical aerator failure, hydraulic
overload caused by leaking toilet

▶ Which of the following is a way to evaluate an aerobic treatment plant for
excessive solids and need for wasting?. Answer: 30-minute settling test

▶ Which of the following is true of standard intermittent sand filter?.
Answer: provides secondary wastewater treatment, has a maximum
surface loading rate of 1.2 gal/day/sqft, requires at least 24 inches of filter
media which meets definite specifications (ASTM C-33)

▶ When would an intermittent sand filter with disinfection system be
selected over a properly designed and installed septic tank system?.
Answer: For a standard drainfield in class Ia soil

▶ Trickling filters and wetlands. Answer: are secondary treatment
processes

▶ Which of the following considerations should receive the greatest
emphasis in selecting a type of OSSF disposal option?. Answer: soil and
site conditions

▶ On a West Texas site with 16 inches of Class Ia soil over fractured rock,
suitable OSSFs would include. Answer: lined ET or mound systems

▶ What are the minimum soil requirements for leaching chambers or
gravelless pipe systems following a septic tank?. Answer: The same as for
a standard absorptive drainfield, 2 feet of well-drained Class Ib, II, or III soil
below the field bottom

▶ OSSF surface application always requires. Answer: at least secondary
treatment and disinfection

▶ Surface application is often selected over other OSSF disposal options
because of. Answer: clay soils and/or seasonal groundwater problems

▶ What must be known to determine the size of spray area required for an
OSSF spray irrigation system?. Answer: Rate of irrigation (Ri) allowed in
that area and (Q) in gal/day

, ▶ Systems that routinely require a pump tank include. Answer: surface and
drip irrigation and sand filters

▶ The setback from a public water well for an aerobic plant is. Answer: 50
feet

▶ A maintenance provider for a surface application OSSF using a
proprietary aerobic plant must have an employee who is. Answer: a
licensed maintenance provider or a registered maintenance technician

▶ OSSF disposal systems that are routinely required to have maintenance
contracts are. Answer: surface and subsurface drip irrigation

▶ What is the purpose of requiring an affidavit to be filed with the county
real property records for a surface application system?. Answer: to notify
future property owners of the type of OSSF used and the maintenance
requirements

▶ When a maintenance contract is required for a single-family residence
OSSF, the minimum frequency of site visits and type of testing is. Answer:
once every four months with chlorine residual or fecal coliform testing

▶ Required samples for testing from a surface application system are
collected from. Answer: the pump tank effluent line port

▶ An LPD system for a new three-bedroom home with 2200 Sq ft (having
water-saving devices) with 9-inch-wide trenches with 1 foot of gravel depth
installed in Class III soil would require __________ linear feet of dosing
pipe.. Answer: 400

▶ An important part of the installation of an LPD system is. Answer:
checking and adjusting pressure on lines

▶ Drip irrigation systems are most sensitive to which type of contaminant?.
Answer: suspended solids

▶ A drip irrigation system must. Answer: be equipped with mechanisms to
flush from the drainfield back to the treatment unit or pump tank

Document information

Uploaded on
August 16, 2026
Number of pages
40
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
£13.66

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
1
Followers
0
Items
1197
Last sold
3 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions