100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

“RADIATION PROTECTION RADIATION SAFETY + REVIEW AND ESSENTIALS PROGRAM MOCK EXAM 2026 ”LATEST EXAM 2026 – 2027 SOLVED QUESTIONS & ANSWERS VERIFIED 100% GRADED A+ (LATEST VERSION) WELL REVISED 100% GUARANTEE PASS

Rating
-
Sold
-
Pages
187
Grade
A+
Uploaded on
22-01-2026
Written in
2025/2026

“RADIATION PROTECTION RADIATION SAFETY + REVIEW AND ESSENTIALS PROGRAM MOCK EXAM 2026 ”LATEST EXAM 2026 – 2027 SOLVED QUESTIONS & ANSWERS VERIFIED 100% GRADED A+ (LATEST VERSION) WELL REVISED 100% GUARANTEE PASS

Institution
BSc Nursing , Nclex
Course
BSc Nursing , Nclex











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
BSc Nursing , Nclex
Course
BSc Nursing , Nclex

Document information

Uploaded on
January 22, 2026
Number of pages
187
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Page 1 of 187




“NRRPT PREP RADIATION FUNDAMENTALS 2026
”LATEST EXAM 2026 – 2027 SOLVED QUESTIONS &
ANSWERS VERIFIED 100% GRADED A+ (LATEST
VERSION) WELL REVISED 100% GUARANTEE PASS



NRRPT prep Radiation Fundamentals




Question Number: 1
Fundamentals of Radiation Protection


A low energy alpha detector is usually effective if the detector is distant from
the source.


A) 1/4 inch
B) 1/2 inch
C) 1 inch
D) 1 1/2 inches
E) 2 inches
The correct answer is: A


Low energy alpha particles can only travel less than 1/2 inch in air. Therefore, one
must be closer than this to detect them.
Question Number: 2
Fundamentals of Radiation Protection

, Page 2 of 187


A sample of I-131 (half life = 8 days) is kept for 80 days, at which time the
activity is 1 µCi . What was the original activity?


A) 2.0 mCi
B) 1.0 mCi
C) 1.5 mCi
D) 3.5 mCi
E) 4.0 mCi
The correct answer is: B


After 10 half lives, the remaining activity is approximately 1000th of the original
amount. Therefore, if there was 1
µCi left after 10 half lives, then there must have been 1000 times more to start with.
Hence, 1 µCi * 1000 = 1 mCi.
Question Number: 3
Fundamentals of Radiation Protection


A sample of radioactive material is reported to contain 2000 picocuries of
activity. Express this value as


disintegrations per minute.


A) 370 dpm
B) 900 dpm
C) 3770 dpm
D) 4440 dpm
E) 5320 dpm
The correct answer is: D


dps = (2000 pCi)(1 x 10^-12Ci/pi )(3.7x10^10 dps/Ci) dps = 74
dpm = (74 dps) (60 sec/min)
dpm = 4440
Remember to convert to disintegrations per minute not DISINTEGRATIONS PER
SECOND.

, Page 3 of 187


Question Number: 4
Fundamentals of Radiation Protection


A sample of wood from an ancient forest showed 93.75% of the Carbon-14
decayed. How many half lives did the carbon go through?


A) 1
B) 2
C) 3
D) 4
E) 5
The correct answer is: D


1 half life = 50% remaining
2 half lives = 25% remaining
3 half lives = 12.5% remaining
4 half lives = 6.25% remaining
Question Number: 5
Fundamentals of Radiation Protection


A worker accidentally ingested one mCi of tritium. Tritium has a half life of 12
years. The number of disintegrations per second in the worker's body is which
of the following?




A) 3.7 x 10^7dps
B) 2.5 x 10^3 dps
C) 1.7 x 10^8 dps
D) 2.2 x 10^6 dps
E) 3.7 x 10^10 dps
The correct answer is: A


By definition, 1 mCi = 3.7 x 10^7 dps. Dps stands for disintegrations per second.

, Page 4 of 187


Therefore, if one mCi of tritium is ingested, the number of disintegrations per second
must be 3.7 x 10^7.
Question Number: 6
Fundamentals of Radiation Protection


Calculate the absorbed dose rate produced in bone (f = 0.922) by a 1MeV
gamma radiation source which produced an exposure rate of 0.5mr/hr.


A) 0.37 mrads/hr
B) 0.4 mrads/hr
C) 0.32 mrads/hr
D) 0.004 mrads/hr
E) 0.002 mrads/hr
The correct answer is: B


D = 0.87 f X (in rads)
= 0.869 0.922 5 x 10^-3rads/hr
= 0.4 x 10^-3rads/hr
= 0.4 mrads/hr


Where D = absorbed dose rate
Question Number: 7
Fundamentals of Radiation Protection


Conjunctivitis may result from a welding arc due to:


A) intense visible light radiation.
B) UV radiation.
C) IR radiation.
D) soft x-ray radiation.
E) spark.
The correct answer is: B
CA$81.25
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
ernestmugo
5.0
(1)

Get to know the seller

Seller avatar
ernestmugo Chamberlain College Nursing
Follow You need to be logged in order to follow users or courses
Sold
2
Member since
7 months
Number of followers
0
Documents
571
Last sold
6 days ago
Best Quality revision materials

Best quality exams Latest exams Previous exams Which are graded A+ and verified 100% Study guides Quality notes Recommended for students to help them ease their revisions and understand the content well

5.0

1 reviews

5
1
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions