Q-01 FDNY Exam Newest /Q-01 FDNY Exam Preparation/Q-01 FDNY Practice Exam With Complete
Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!
Rupture members, when used in parallel with a relief valve, are not to exceed _____% above designed
working pressure -(ANSWER)20%
Butterfly valve: where can it be used? -(ANSWER)Can be used on the inlet and outlet of a water pump
What electrical motor protection device automatically resets itself? -(ANSWER)The thermal protector
746 watts equals how many kilowatt hours? -(ANSWER).746 kilowatt hours
What position is the liquid line service valve normally in? -(ANSWER)Back-seated
In an operating evaporator, oil stays on top of which refrigerant? -(ANSWER)Carbon dioxide, R-744
At what pressure does the relief valve blow on a high pressure machine? -(ANSWER)300 psi
What would indicate a restriction (such as dirt or scale) in the liquid line? -(ANSWER)Frost immediately
after the restriction
What does solubility mean? -(ANSWER)The ability of a refrigerant to mix with other substances
Charging Vapor —In a compression system, where do you charge the vapor? -(ANSWER)Suction side of
the compressor at the Suction Service Valve
When comparing a brine with s PH of 8 to one with a PH of 10, its alkalinity is: -(ANSWER)100 times
greater (ex. PH 8 to PH 9 is 10 times greater)
In an efficiently operating induced draft cooling tower, the leaving water is between: -(ANSWER)Dry
bulb and wet bulb temperature
,Q-01 FDNY Exam Newest /Q-01 FDNY Exam Preparation/Q-01 FDNY Practice Exam With Complete
Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!
To produce the desired evaporator temperature, the power input is reduced by keeping head pressure...
-(ANSWER)Head pressure as low as possible & suction pressure as high as needed
The accumulator is usually between the... -(ANSWER)Compressor and evaporator
An oiling system in a large centrifugal system should consist of at least... -(ANSWER)Reservoir, pump and
distribution lines
In an evaporator that chills brine, the greatest cooling effect on the brine results from the... -
(ANSWER)Boiling of low pressure liquid
The flow of weak liquor to the absorber is controlled by
A) gas pressure
B) throttling device
C) float valve
D) pressure of the strong liquor pump -(ANSWER)B) throttling device
The best way of detecting ammonia brine is by using
A) CO2 gas
B) potassium of lime
C) Nessler reagent
D) carbonate of soda -(ANSWER)C) Nessler reagent
The best time to purge an ammonia plant with 250 lbs. of ammonia is
A) during shut-down, because you will lose ammonia
B) while charging the plant
C) during operation
D) none of the above -(ANSWER)C) during operation
,Q-01 FDNY Exam Newest /Q-01 FDNY Exam Preparation/Q-01 FDNY Practice Exam With Complete
Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!
What will make the strong liquor in the absorber decrease?
A) expansion valve open too much
B) A decrease in evaporator load
C) An increase in evaporator load
D) Too much steam on the generator -(ANSWER)B) A decrease in evaporator load
Which of the following statements is incorrect?
A) A service valve is a key-operated shut-off valve used during shipment, installation and repairs
B) Brine is a liquid cooled by refrigeration and used for the transmission of heat
C) A fusible plug has a set-temperature fusible member to relieve pressure
D) A rupture member automatically ruptures at a predetermined temperature -(ANSWER)D) A rupture
member automatically ruptures at a predetermined temperature
Oil in a refrigerant should
A) have a high pour point
B) have a low flash point
C) have a high viscosity
D) not contain moisture -(ANSWER)D) not contain moisture
In an NH3 dry expansion evaporator with TXV and bulb clamped properly on the outlet of the
evaporator, the superheat is
A) 7 to 10° F
B) 5 to 9° F
C) 20 to 30° F
D) 1 to 2° F -(ANSWER)A) 7 to 10° F
The setting of a fusible plug is
, Q-01 FDNY Exam Newest /Q-01 FDNY Exam Preparation/Q-01 FDNY Practice Exam With Complete
Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!
A) 280° F
B) 300° F
C) 380° F
D) 300 psig. -(ANSWER)A) 280° F
If the insulation was removed from the bulb of the expansion valve, what would happen? -
(ANSWER)Flooded evaporator —the TXV bulb opens in a range from 45 to 85° F. If the insulation was
removed, the bulb would sense the temperature in the machine room and keep the TXV open, thus
flooding the evaporator.
On the most common three-phase, four-wire service, the voltage between any phase and neutral should
be
A) 105 volts
B) 120 volts
C) 208 volts
D) 220 volts -(ANSWER)B) 120 volts
A refrigerant overcharge would
A) increase head pressure
B) decrease head pressure
C) decrease solution-side pressure
D) decrease discharge-side pressure -(ANSWER)A) increase head pressure
A dryer is generally installed with other equipment in a commercial Freon compressor system. The
recommended location of this dryer is on the
A) high-pressure line between condenser and reciever
B) suction line between evaporator and compressor
C) discharge line between compressor and condenser
Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!
Rupture members, when used in parallel with a relief valve, are not to exceed _____% above designed
working pressure -(ANSWER)20%
Butterfly valve: where can it be used? -(ANSWER)Can be used on the inlet and outlet of a water pump
What electrical motor protection device automatically resets itself? -(ANSWER)The thermal protector
746 watts equals how many kilowatt hours? -(ANSWER).746 kilowatt hours
What position is the liquid line service valve normally in? -(ANSWER)Back-seated
In an operating evaporator, oil stays on top of which refrigerant? -(ANSWER)Carbon dioxide, R-744
At what pressure does the relief valve blow on a high pressure machine? -(ANSWER)300 psi
What would indicate a restriction (such as dirt or scale) in the liquid line? -(ANSWER)Frost immediately
after the restriction
What does solubility mean? -(ANSWER)The ability of a refrigerant to mix with other substances
Charging Vapor —In a compression system, where do you charge the vapor? -(ANSWER)Suction side of
the compressor at the Suction Service Valve
When comparing a brine with s PH of 8 to one with a PH of 10, its alkalinity is: -(ANSWER)100 times
greater (ex. PH 8 to PH 9 is 10 times greater)
In an efficiently operating induced draft cooling tower, the leaving water is between: -(ANSWER)Dry
bulb and wet bulb temperature
,Q-01 FDNY Exam Newest /Q-01 FDNY Exam Preparation/Q-01 FDNY Practice Exam With Complete
Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!
To produce the desired evaporator temperature, the power input is reduced by keeping head pressure...
-(ANSWER)Head pressure as low as possible & suction pressure as high as needed
The accumulator is usually between the... -(ANSWER)Compressor and evaporator
An oiling system in a large centrifugal system should consist of at least... -(ANSWER)Reservoir, pump and
distribution lines
In an evaporator that chills brine, the greatest cooling effect on the brine results from the... -
(ANSWER)Boiling of low pressure liquid
The flow of weak liquor to the absorber is controlled by
A) gas pressure
B) throttling device
C) float valve
D) pressure of the strong liquor pump -(ANSWER)B) throttling device
The best way of detecting ammonia brine is by using
A) CO2 gas
B) potassium of lime
C) Nessler reagent
D) carbonate of soda -(ANSWER)C) Nessler reagent
The best time to purge an ammonia plant with 250 lbs. of ammonia is
A) during shut-down, because you will lose ammonia
B) while charging the plant
C) during operation
D) none of the above -(ANSWER)C) during operation
,Q-01 FDNY Exam Newest /Q-01 FDNY Exam Preparation/Q-01 FDNY Practice Exam With Complete
Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!
What will make the strong liquor in the absorber decrease?
A) expansion valve open too much
B) A decrease in evaporator load
C) An increase in evaporator load
D) Too much steam on the generator -(ANSWER)B) A decrease in evaporator load
Which of the following statements is incorrect?
A) A service valve is a key-operated shut-off valve used during shipment, installation and repairs
B) Brine is a liquid cooled by refrigeration and used for the transmission of heat
C) A fusible plug has a set-temperature fusible member to relieve pressure
D) A rupture member automatically ruptures at a predetermined temperature -(ANSWER)D) A rupture
member automatically ruptures at a predetermined temperature
Oil in a refrigerant should
A) have a high pour point
B) have a low flash point
C) have a high viscosity
D) not contain moisture -(ANSWER)D) not contain moisture
In an NH3 dry expansion evaporator with TXV and bulb clamped properly on the outlet of the
evaporator, the superheat is
A) 7 to 10° F
B) 5 to 9° F
C) 20 to 30° F
D) 1 to 2° F -(ANSWER)A) 7 to 10° F
The setting of a fusible plug is
, Q-01 FDNY Exam Newest /Q-01 FDNY Exam Preparation/Q-01 FDNY Practice Exam With Complete
Questions And Correct Detailed Answers (Verified Answers) |Already Graded A+|Brand New Version!!
A) 280° F
B) 300° F
C) 380° F
D) 300 psig. -(ANSWER)A) 280° F
If the insulation was removed from the bulb of the expansion valve, what would happen? -
(ANSWER)Flooded evaporator —the TXV bulb opens in a range from 45 to 85° F. If the insulation was
removed, the bulb would sense the temperature in the machine room and keep the TXV open, thus
flooding the evaporator.
On the most common three-phase, four-wire service, the voltage between any phase and neutral should
be
A) 105 volts
B) 120 volts
C) 208 volts
D) 220 volts -(ANSWER)B) 120 volts
A refrigerant overcharge would
A) increase head pressure
B) decrease head pressure
C) decrease solution-side pressure
D) decrease discharge-side pressure -(ANSWER)A) increase head pressure
A dryer is generally installed with other equipment in a commercial Freon compressor system. The
recommended location of this dryer is on the
A) high-pressure line between condenser and reciever
B) suction line between evaporator and compressor
C) discharge line between compressor and condenser