ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS

Rating
-
Sold
-
Pages
76
Grade
A+
Uploaded on
14-11-2025
Written in
2025/2026

ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS

Institution
ARRT RADIOGRAPHY
Course
ARRT RADIOGRAPHY











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
ARRT RADIOGRAPHY
Course
ARRT RADIOGRAPHY

Document information

Uploaded on
November 14, 2025
Number of pages
76
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS
LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL
ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS

The target angle of the anode allows for a ________ actual focal spot, while producing a ________
effective focal spot. This effect is known as the ________. - CORRECT ANSWERS 1) Larger

2) Smaller

3) Line Focus Principle



The target angle may be ________ to ________ degrees, depending on the tube design. - CORRECT
ANSWERS 1) 7

2) 20



When electrons travel from the cathode to the anode, they travel at up to ________ the speed of
________. - CORRECT ANSWERS 1) Half

2) Light



When electrons strike the anode, the kinetic energy converts the electrons into ________ and
________. - CORRECT ANSWERS 1) Heat

2) X-Rays



When striking the anode, the electron conversion to heat is approximately ________%. - CORRECT
ANSWERS 99.8



When striking the anode, the electron conversion to x-rays is approximately ________%. - CORRECT
ANSWERS 0.2



________ are a calculation of the total heat produced during an x-ray exposure. - CORRECT
ANSWERS Heat Units



Heat units for single-phase full-wave rectified equipment is calculated via this formula: - CORRECT
ANSWERS kVp x mAs

,ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS
LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL
ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS

Heat units for three-phase, six-pulse full-wave rectified equipment is calculated via this formula: -
CORRECT ANSWERS kVp x mAs x 1.35



Heat units for three-phase, twelve-pulse full-wave rectified equipment is calculated via this formula: -
CORRECT ANSWERS kVp x mAs x 1.41



The x-ray tube for fluoroscopy is operated at ________ to ________ mA. - CORRECT ANSWERS
1) 3

2) 5



kVp and mAs are automatically adjusted during fluoroscopy by a process known as ________. -
CORRECT ANSWERS Automatic Brightness Control (ABC)



Automatic brightness control is also called ________ or ________. - CORRECT ANSWERS 1)
Automatic Brightness Stabilization

2) Automatic Gain Control



The ________ receives exit rays from the patient and converts then into visible light. - CORRECT
ANSWERS Input Phosphor



Visible light from the input phosphor strikes the ________, which is a thin layer next to the input
phosphor. - CORRECT ANSWERS Photocathode



The photocathode releases electrons in amounts ________ proportional to the visible light striking it. -
CORRECT ANSWERS Directly



Electrons from the photocathode are concentrated and directed toward the other end of the image-
intensifier tube by a series of ________ and by ________ kVp applied through the tube. - CORRECT
ANSWERS 1) Electrostatic Lenses (Focusing Lenses)

2) 25

,ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS
LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL
ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS


Once electrons are propelled across the tube from the photocathode, they strike the ________. -
CORRECT ANSWERS Output Phosphor



Once the energy of the electrons hits the output phosphor, it is converted by the phosphor to ________
in amounts ________ to ________ times greater than the photocathode. - CORRECT ANSWERS
1) Visible Light

2) 50

3) 75



The increase in brightness from the photocathode to the output phosphor is known as ________. -
CORRECT ANSWERS Flux Gain



The ________ phosphor is smaller than the ________ phosphor, resulting in an increase in brightness
known as ________. - CORRECT ANSWERS 1) Output

2) Input

3) Minification Gain



Total brightness gain is a product of ________ gain and ________ gain. - CORRECT ANSWERS 1)
Minification

2) Flux



Total brightness gain ranges from ________ to ________, and decreases as the tube ages. - CORRECT
ANSWERS 1) 5000

2) 20000



A complete program in a radiology department that addresses all aspects of quality, including customer
service, image interpretation, accuracy of diagnosis, and distribution of radiologists' reports is known as:
- CORRECT ANSWERS Quality Assurance

, ARRT RADIOGRAPHY EXAM REVIEW QUESTIONS AND ANSWERS
LATEST DOWNLOADED 2025/2026 A COMPLETE SOLUTION ALL
ANSWERS 100% CORRECT DETAILED BEST GRADED A+ FOR PASS

A program that specifically addresses the safe and reliable operation of equipment is known as: -
CORRECT ANSWERS Quality Control



A quality control program is required by ________. - CORRECT ANSWERS The Joint Commission



Collimation must be accurate to within ________% of the source-to-image receptor distance. -
CORRECT ANSWERS 2



The effective focal spot size should be within ________% of the size stated in the equipment
specifications. - CORRECT ANSWERS 50



kVp must be accurate to within ________% of the kVp indicated. - CORRECT ANSWERS 10



The exposure timer should be accurate to within ________% of the time chosen for exposures over 10
ms. - CORRECT ANSWERS 5



Adjacent mA stations should be accurate to within ________% of one another. This is known as
________. - CORRECT ANSWERS 1) 10

2) Exposure Linearity



Radiation intensity of sequential exposures should not vary more than ________%. This is known as
________. - CORRECT ANSWERS 1) 5

2) Exposure Reproduceability



The fluoroscopy exposure rate should be tested with a digital dosimeter, and should not be more
than________ per minute. - CORRECT ANSWERS 100 mGyᵃ



CR plates should be erased at least every ________. - CORRECT ANSWERS 48 Hours

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
bestScience Chamberlain College Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
74
Member since
3 year
Number of followers
61
Documents
3614
Last sold
1 month ago

3.2

9 reviews

5
3
4
2
3
0
2
2
1
2

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions