100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Test Bank for Textbook of Diagnostic Sonography 9th Edition by Sandra L. Hagen-Ansert |ISBN: 9780323826488| Guide A+

Beoordeling
-
Verkocht
-
Pagina's
439
Cijfer
A+
Geüpload op
06-11-2025
Geschreven in
2025/2026

Test Bank for Textbook of Diagnostic Sonography 9th Edition by Sandra L. Hagen-Ansert |ISBN: 9780323826488| Guide A+

Instelling
Textbook Of Diagnostic Sonography
Vak
Textbook of Diagnostic Sonography











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Textbook of Diagnostic Sonography
Vak
Textbook of Diagnostic Sonography

Documentinformatie

Geüpload op
6 november 2025
Aantal pagina's
439
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

@PROFDOCDIGITALLIBRARIES

Hagen-Ansert: Textbook of Diagnostic Sonography 9/E Test Bank

Chapter 01: Foundations of Clinical Sonography
(COMPLETE TEST BANK WITH QUESTIONS & VERIFIED ANSWERS)

MULTIPLE CHOICE

1. Historically, the development of ultrasound began shortly after:
a. radio communication in World War I.
b. sonar in World War II.
c. nuclear testing in World War II.
d. the launching of Sputnik.

ANS: B
World War II brought sonar equipment to the forefront for defense purposes. Ultrasound was
influenced by the success of sonar equipment.
PR
PTS: 1
OBJ: Detail a timeline for pioneers in the advancement of medical diagnostic ultrasound.
TOP: Historical overview of sound theory and medical ultrasound

2. The early applications of obstetric ultrasound were initiated by:
a. Joseph Holmes and Douglas Howry.
O
b. Ian Donald and Tom Brown.
c. Hellmuth Hertz and Inge Edler.
d. William Fry and Russell Meyers.
FD
ANS: B
The early obstetric compound scanner was built by Tom Brown and Dr. Ian Donald in
Scotland in 1957.

PTS: 1
O
OBJ: Detail a timeline for pioneers in the advancement of medical diagnostic ultrasound.
TOP: Historical overview of sound theory and medical ultrasound
C
3. Visualization of the cardiac structures in the heart was discovered by:
a. Joseph Holmes.
b. Ian Donald.
c. Hertz and Edler.
d. George Ludwig.

ANS: C
In 1954, echocardiographic techniques were developed in Sweden by Drs. C.H. Hertz and I.
Edler.

PTS: 1
OBJ: Detail a timeline for pioneers in the advancement of medical diagnostic ultrasound.
TOP: Historical overview of sound theory and medical ultrasound

4. Which one of the following statements about the role of sonographers is false?
a. Sonographers perform ultrasound studies and gather diagnostic data independent
of the physician.
b. Sonographers must possess intellectual curiosity and perseverance.

,@PROFDOCDIGITALLIBRARIES
c. Sonographers must have a technical aptitude.
d. Sonographers must be able to communicate on different levels.

ANS: A
A sonographer performs ultrasound studies gathering diagnostic data under both the direct and
the indirect supervision of a physician. They also must assess clinical history and symptoms,
interpret laboratory values, and understand other diagnostic examinations.

PTS: 1 OBJ: Describe the role of the sonographer.
TOP: Role of the sonographer

5. In soft tissues, the assumed propagation velocity is (in meters per second):
a. 1320.
b. 1450.
c. 1540.
d. 1650.

ANS: C
PR
In soft tissues, the assumed propagation velocity (speed) is 1540 meters per second.

PTS: 1
OBJ: Demonstrate an understanding of the basic principles and terminology of ultrasound.
TOP: Introduction to basic ultrasound principles – Acoustics
O
6. Diagnostic ultrasound uses the frequencies of:
a. 10 to 15 kHz.
b. 1 to 20 kHz.
FD
c. 100 to 1000 Hz.
d. 1 to 20 MHz.

ANS: D
Diagnostic application of ultrasound uses frequencies of 1 to 20 million cycles per second (1
to 20 MHz).
O
PTS: 1
OBJ: Demonstrate an understanding of the basic principles and terminology of ultrasound.
TOP: Introduction to basic ultrasound principles – Acoustics
C

7. The device that converts energy from one form to another is called the:
a. digitizer.
b. transducer.
c. scan converter.
d. beam former.

ANS: B
Piezoelectric elements (transducers) convert electric energy into ultrasound energy and vice
versa.

PTS: 1
OBJ: Demonstrate an understanding of the basic principles and terminology of ultrasound.
TOP: Transducer Selection in a Clinical Imaging Practice

8. The angle of reflection is equal to the:

,@PROFDOCDIGITALLIBRARIES
a. acoustic impedance.
b. angle of incidence.
c. refraction.
d. image resolution.

ANS: B
Angle of reflection is the angle between the reflected sound direction and a line perpendicular
to the media boundary.

PTS: 1
OBJ: Demonstrate an understanding of the basic principles and terminology of ultrasound.
TOP: Propagation of sound through tissue

9. The display mode that shows time along the horizontal axis and depth along the vertical axis
is:
a. A mode.
b. B mode.
PR
c. M-mode.
d. real-time.
ANS: C
Motion mode (M-mode) displays the depth along the vertical axis versus the time along the
horizontal axis.
O
PTS: 1 OBJ: Identify ultrasound instruments and discuss their uses.
TOP: Pulse-echo display modes – M-mode
FD
10. Which one of the following statements about the Doppler principle is false?
a. Doppler refers to a change in frequency in which the motion of laminar or
turbulent flow is detected within a vascular structure.
b. The beam should be perpendicular to the flow.
c. The Doppler shift is directly proportional to the velocity of the red blood cell.
d. If the red blood cell moves away from the transducer, then the fall in frequency is
O
directly proportional to the velocity and direction of the red blood cell movement.
ANS: B
C
The beam should be parallel to the flow to obtain the maximum velocity. The frequency of the
Doppler shift is proportional to the cosine of the Doppler angle. At a 90-degree angle
(perpendicular to flow), the Doppler shift is zero, regardless of the flow velocity.

PTS: 1 OBJ: Discuss three-dimensional and Doppler ultrasound.
TOP: Doppler Ultrasound – Doppler Effect

11. The Fresnel zone is also called the:
a. far field.
b. focal point.
c. near zone.
d. Nyquist limit.

ANS: C
The Fresnel or near zone is the field closest to the transducer during the formation of the
sound beam.

, @PROFDOCDIGITALLIBRARIES
PTS: 1
OBJ: Demonstrate an understanding of the basic principles and terminology of ultrasound.
TOP: System Controls for Image Optimization – Focal Zone

12. The higher the transducer frequency, the:
a. shorter the wavelength.
b. faster the frame rate.
c. deeper the penetration depth.
d. slower the frame rate.

ANS: A
The higher the frequency, the shorter the wavelength (inversely related).

PTS: 1
OBJ: Demonstrate an understanding of the basic principles and terminology of ultrasound.
TOP: Introduction to basic ultrasound principles – Frequency

13. The unit utilized to measure the intensity, amplitude, and power of an ultrasound wave is
PR
called a:
a. kilohertz.
b. megahertz.
c. decibel.
d. milliwatt.
O
ANS: C
The decibel unit is used to measure the intensity, amplitude, and power of an ultrasound wave.
FD
PTS: 1
OBJ: Demonstrate an understanding of the basic principles and terminology of ultrasound.
TOP: Introduction to basic ultrasound principles – Measurement of sound

14. The redirection of sound in multiple directions is known as:
a. refraction.
O
b. scattering.
c. absorption.
d. resistance.
C
ANS: B
Scattering refers to the redirection of sound in multiple directions.

PTS: 1
OBJ: Demonstrate an understanding of the basic principles and terminology of ultrasound.
TOP: Introduction to basic ultrasound principles – Propagation of sound through tissue

15. The ability of an imaging process to distinguish adjacent structures in an object is called:
a. resolution.
b. pulse duration.
c. slice thickness.
d. attenuation.

ANS: A

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
JNURSE Chamberlain College Of Nursing
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
202
Lid sinds
2 jaar
Aantal volgers
70
Documenten
996
Laatst verkocht
3 dagen geleden
JNurse Libraries: Your Digital, Reliable and Excellent Nursing Partner

Welcome to JNURSE! The place to find the best study materials for various subjects. You can be assured that you will receive only the best which will help you to ace your exams. All the materials posted are A+ Graded. Please rate and write a review after using my materials. Your reviews will motivate me to add more materials. Thank you very much!

4.2

23 beoordelingen

5
16
4
1
3
2
2
3
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen