CRITICAL CARE 240 / NUR 240 COMPLETE STUDY GUIDE ON CARDIOVASCULAR SYSTEM (LATEST 2025/2026 UPDATE) TERMS & COMPLETE DEFINITIONS- COMMUNITY COLLEGE OF ALLEGHENY COUNTY Cardiovascular System Standard 12 Lead electrocardiogram- records electrical impulses as they travel though the heart. Uses of the 12-lead electrode placement - Detect dysrhythmias - Determine electrical axis - Enlargement patterns - Ventricular hypertrophy - Atrial enlargement - Ischemia injury and infarction patterns - Identification of prolonged QT intervals TYPES OF CARDIAC MONITORING SYSTEMS. - There are 2 types. 1. Continuous Hard wire monitoring systems - The pt is linked directly to the cardiac monitor through the ECG cable. - Used in ICU- used with pts confined in bed - The information is displayed at bedside and the central monitor - Hard wire monitors operate on electricity but are well isolated so that h20, blood, and other fluids do not pose an electrical hazard if the machine is maintained properly. 2. Telemetry monitoring system - Connected to a small battery operated transmitter - Displayed at the central monitoring station Dysthymias and the 12-lead electrocardiogram Evaluation of a rhythm strip - Must note too fast, slow or deadly The paper consists of Vertical and Horizontal lines each 1mm apart. Dark lines Thin lines Large square lines- (large boxes)- Each large box consists of 5 small boxes across and 5 small boxes down. The Vertical lines (up and down)- the height measures the voltage- how much electricity is there. Each Small square measured vertically is 1 Millimeter and the large square is 5mm. Height- measured by counting the lines vertically. - amplitude Horizontal lines. - time measurement (pay close attention to this) - each small squares measured horizontally = 0.04 seconds For example, If there are 5 small boxes= 0.04*5 = 0.20 seconds (this makes 1 big box) If there are 5 big boxes= 5*0.20 = 1 second. ECG paper • Small boxes = 0.04 seconds • Large box = 0.20 seconds Conductivity- Ability of cardiac cells to transmit impulses. The electrical conduction system causes the heart to contract and relax in order to pump blood. Polarization = resting - At cardiac cell membrane at rest (resting heart cells) =Vev no electrical activity - Inside the cell is more negative than the outside= polarized - K+ ions leak out Resting Heart Cell - - At rest, the heart cell is negatively charged on the inside due to a difference in ion concentrations - - This is known as the cell being polarized Depolarization= contraction - occurs when the cell membrane becomes more permeable to sodium, causing the cell to contract - Reversal of electrical charge. - Rapid influx of sodium ions. When the cell receives an electrical signal, the cell membrane becomes more permeable to sodium - Sodium enters the cell, causing the cell to become less negative or more positive. This is known as depolarization

Show more Read less










Whoops! We can’t load your doc right now. Try again or contact support.

Document information

Uploaded on
November 4, 2025
Number of pages
23
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

CRITICAL CARE 240 / NUR 240 COMPLETE
STUDY GUIDE ON CARDIOVASCULAR SYSTEM
(LATEST 2025/2026 UPDATE) TERMS &
COMPLETE DEFINITIONS- COMMUNITY
COLLEGE OF ALLEGHENY COUNTY


Cardiovascular System
Standard 12 Lead electrocardiogram- records electrical impulses as they travel
though the heart.
Uses of the 12-lead electrode placement

- Detect dysrhythmias
- Determine electrical axis
- Enlargement patterns
- Ventricular hypertrophy
- Atrial enlargement
- Ischemia injury and infarction patterns
- Identification of prolonged QT intervals
TYPES OF CARDIAC MONITORING SYSTEMS. - There are 2 types.
1. Continuous Hard wire monitoring systems
- The pt is linked directly to the cardiac monitor through the ECG cable.
- Used in ICU- used with pts confined in bed
- The information is displayed at bedside and the central monitor




1

, - Hard wire monitors operate on electricity but are well isolated so that h20,
blood, and other fluids do not pose an electrical hazard if the machine is
maintained properly.
2. Telemetry monitoring system
- Connected to a small battery operated transmitter
- Displayed at the central monitoring station

Dysthymias and the 12-lead electrocardiogram
Evaluation of a rhythm strip
- Must note too fast, slow or deadly




The paper consists of Vertical and Horizontal lines each 1mm apart. Dark

lines

Thin lines
Large square lines- (large boxes)- Each large box consists of 5 small boxes across
and 5 small boxes down.




2

, The Vertical lines (up and down)- the height measures the voltage- how much
electricity is there.
Each Small square measured vertically is 1 Millimeter and the large square is
5mm.
Height- measured by counting the lines vertically. - amplitude
Horizontal lines. - time measurement (pay close attention to this)
- each small squares measured horizontally = 0.04 seconds
For example,
If there are 5 small boxes= 0.04*5 = 0.20 seconds (this makes 1 big box)
If there are 5 big boxes= 5*0.20 = 1 second.
ECG paper
• Small boxes = 0.04 seconds
• Large box = 0.20 seconds

Conductivity- Ability of cardiac cells to transmit impulses. The
electrical conduction system causes the heart to contract and relax in
order to pump blood.
Polarization = resting
- At cardiac cell membrane at rest (resting heart cells) =Vev no electrical
activity
- Inside the cell is more negative than the outside= polarized - K+ ions
leak out


3

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Exampage Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
6007
Member since
2 year
Number of followers
18
Documents
1618
Last sold
1 week ago
Studying Nursing & Other Courses❓ Shop the most resent doc's here, at BEST Prices And race Against time❤️

We are trusted experienced professional experts working as study material sourcing agents, We offer authentic & meticulously crafted exam papers, directly sourced from reputable institutions, Our papers serve as invaluable tools to aid aspiring nurses and many other professions in their exam preparations. STUDY LESS STUDY SMART

4.5

2015 reviews

5
1177
4
620
3
181
2
29
1
8

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions