Verified Multiple Choice and Conceptual Actual
Frequently Tested Exam Questions With
Reviewed 100% Correct Detailed Answers
Guaranteed Pass!!Current Update!!
Q1. Backpressure occurs when:
A) The supply pressure is lower than system pressure
B) The system pressure is lower than supply
C) Atmospheric pressure reverses flow
D) The air inlet fails
Q2. A BPAT tester must submit test results to:
A) EPA
B) Manufacturer’s representative
C) Administrative authority
D) State senator
Q3. Test reports for backflow prevention assemblies must typically be:
A) Oral reports by phone
B) Completed on approved forms
C) Sent directly to the customer
D) Optional unless failure occurs
Q4. Which assembly must always be tested at installation?
A) Double Check (DC)
,B) Dual check
C) AVB
D) PVB
Q5. How often should health hazard backflow prevention assemblies be tested?
A) Every 3 months
B) Annually
C) Every 5 years
D) Only if a problem occurs
Q6. Backflow incidents are most often reported to which agency first?
A) Fire Department
B) Administrative authority
C) State governor
D) Manufacturer
Q7. Which document outlines procedures for responding to contamination
events?
A) Owner’s manual
B) Emergency response plan
C) Backflow tester log
D) OSHA safety manual
Q8. In most states, who is legally responsible for installing and maintaining
backflow devices?
A) The customer
B) The water purveyor
C) The tester
D) The manufacturer
,Q9. Which of the following is considered a "health hazard"?
A) Increased water bill
B) Aesthetic discoloration
C) Contamination causing illness
D) Reduced water pressure
Q10. Which assembly is most often required for high health hazard cross-
connections?
A) DC
B) RPZ
C) AVB
D) SVB
Q11. Which condition requires immediate notification of the administrative
authority?
A) Pressure drop
B) Failed RPZ test
C) Customer complaint
D) Small leak
Q12. A BPAT tester’s certification must be:
A) Renewed periodically (e.g., every 3 years)
B) Permanent once passed
C) Filed with EPA
D) Signed by the mayor
, Q13. 1 psi is equal to how many feet of water column?
A) 1 ft
B) 2.31 ft
C) 4.34 ft
D) 10 ft
Q14. A 27.75 ft water column exerts approximately what pressure at the base?
A) 0.43 psi
B) 1.0 psi
C) 2.0 psi
D) 10 psi
When responding to a backflow incident, the water purveyor’s first action should
be:
A) Call the mayor
B) Implement the emergency response plan
C) Install a vacuum breaker
D) Wait for state instructions
Q15. Absolute pressure at sea level is:
A) 10 psia
B) 14.7 psia
C) 25 psia
D) 29.7 psia
Q16. An absolute pressure of 25 psia is approximately equal to what gauge
pressure at sea level?
A) 5 psi
B) 10 psi