100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

ARDMS BREAST REGISTRY EXAM AND STUDY GUIDE NEWEST 2024 ACTUAL EXAM 450 QUESTIONS AND CORRECT DETAILED ANSWERS

Beoordeling
-
Verkocht
2
Pagina's
54
Cijfer
A+
Geüpload op
30-07-2025
Geschreven in
2024/2025

ARDMS BREAST REGISTRY EXAM AND STUDY GUIDE NEWEST 2024 ACTUAL EXAM 450 QUESTIONS AND CORRECT DETAILED ANSWERS

Instelling
ARDMS BREAST REGISTRY
Vak
ARDMS BREAST REGISTRY











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
ARDMS BREAST REGISTRY
Vak
ARDMS BREAST REGISTRY

Documentinformatie

Geüpload op
30 juli 2025
Aantal pagina's
54
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

ARDMS BREAST REGISTRY EXAM AND STUDY GUIDE NEWEST 2024 ACTUAL EXAM 450 QUESTIONS AND
CORRECT DETAILED ANSWERS

Artifact - (answer) An echo feature present or absent in a sonographic image that does not correspond
to the presence or absence of a real structure. Eg. enhancement or shadowing.



Attenuation - (answer) The reduction of intensity (and amplitude) of a sound wave as it travels through
a material. Attenuation is due to absorption, reflection, and scattering.



Complex - (answer) A structure in the body that contains both cystic and solid components.



Echogenic - (answer) A structure or medium that produces echoes.



Edge Shadowing - (answer) Decreased echo amplitude distal to the edge of a structure. This artifact
results from refraction of the sound beam.



Enhancement - (answer) Increased echo amplitude returning from regions lying beyond an object that
causes little or no attenuation of the sound beam (typically a cystic structure). This artifact results in a
brighter than normal appearance.



Heterogeneous - (answer) A structure that has an uneven texture (hypoechoic and hyperechoic echoes
throughout). Synonym - non-uniform.



Homogeneous - (answer) Smooth uniform texture



Ipsilateral - (answer) On the same side.



Contrlateral - (answer) On the opposite side.



Isoechoic - (answer) Same echogenicity as another structure or the surrounding tissue.



Noise - (answer) Spurious echoes throughout the image.

,ARDMS BREAST REGISTRY EXAM AND STUDY GUIDE NEWEST 2024 ACTUAL EXAM 450 QUESTIONS AND
CORRECT DETAILED ANSWERS



Real-time - (answer) The scanning and display of sonographic images at a sufficiently rapid rate so that
moving structures can be seen to move at their natural rate. ***Frame rates of 15 frames per second or
greater are considered real time***



Reverberation - (answer) Artifact causing linear echoes parallel to a strong interface. Sound "bounces"



Ring Down - (answer) Reverb in which numerous parallel echoes are seen for a considerable distance.
E.g. a biopsy needle.



Sensitivity - (answer) The ability to diagnose disease in a patient when disease is present.



Texture - (answer) The pattern of echoes seen from a mass or area of interest in the body.



Refractive Edge Shadowing - (answer) Bending of a sound beam and loss of sound energy causing a
shadow.



Mid level gray corresponds to _____ in the breast. - (answer) Fat



Hyperechoic describes what three structures visualized in breast sonography. - (answer) Fibroglandular
tissue, Cooper's Ligament, Skin



What frequency transducer is optimal for breast imaging? - (answer) 7.0-15.0 MHz is optimal for
superior axial and lateral resolution while maintaining penetration to the chest wall. It should also be
BROADBAND.



Fixed elevation focusing represents.... - (answer) Focusing along the short axis of the transducer.



What design of transducer is used in breast imaging? - (answer) Linear array is optimal

,ARDMS BREAST REGISTRY EXAM AND STUDY GUIDE NEWEST 2024 ACTUAL EXAM 450 QUESTIONS AND
CORRECT DETAILED ANSWERS



The advantage of a rectangular image over a sector image is the avoidance of what artifact? - (answer)
Beam divergence



Interventional procedures are more accurately guided with a _______ __________ probe. - (answer)
Linear array



When is a curved array transducer used in breast imaging? - (answer) Pathology too large to fit on
linear image



Most linear transducers in breast sonography are ______ arrays. - (answer) 1-D



1-D arrays offer a fixed focus in the ________ plan (short axis) - (answer) Elevation



1.5-D matrix array transducers have multiple elements along the _____ axis of the probe. - (answer)
Short



1.5-D arrays offer some electronic focusing in the __________ plane. - (answer) Elevation



2-D array transducers are not currently _________. - (answer) available



Imaging depth should penetrate the chest wall-- ___ to ___ cm should be adequate - (answer) 3, 6



An echo's brightness is controlled by ______ - (answer) gain



Know overall gain, TGC, and output power - (answer) This is ultrasound elementary.



If your image is too bright decrease the ______________. - (answer) Output power

, ARDMS BREAST REGISTRY EXAM AND STUDY GUIDE NEWEST 2024 ACTUAL EXAM 450 QUESTIONS AND
CORRECT DETAILED ANSWERS



If your image is too dark increase the ____________. - (answer) Receiver gain



__________ focal zones are recommended for breast imaging. - (answer) Multiple



Multiple focal zones will decrease what? - (answer) Frame rate



a 7-12 MHz probe must be used to obtain an elevation focus depth of ____ to _____ cm. - (answer) 1,2



10 MHz = _____ cm elevation plane focus - (answer) 1.5



____________ (artifact) decreases contrast resolution and spatial resoution (both axial and lateral).
Places unwanted echoes in cysts. - (answer) Volume averaging



_______ __________ is more sensitive to low velocity flow and offers angle independence. - (answer)
Power Doppler



Three reasons Doppler is useful: - (answer) (1)Solid vs Cystic

(2)Inflammed vs Non-Inflammed

(3)Complicated Cyst vs Complex Cyst vs Intraductal Papilloma



To optimize Doppler for breast imaging (4 things) - (answer) (1) Low velocity scale

(2) Low filter setting

(3) Optimal Doppler gain setting

(4) Increased PRF for high velocities
Gratis
Krijg toegang tot het volledige document:
Downloaden

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten

Maak kennis met de verkoper
Seller avatar
Testmister

Ook beschikbaar in voordeelbundel

Thumbnail
Voordeelbundel
Ultimate 500-Exam Mega Prep Bundle | All-in-One Test Bank with Verified Answers
-
500 2026
$ 7,974.52 Meer info

Maak kennis met de verkoper

Seller avatar
Testmister Teachme2-tutor
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
2601
Lid sinds
1 jaar
Aantal volgers
0
Documenten
1080
Laatst verkocht
1 week geleden

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen