Design, material, and operational standards for DCVA & RPBA are found in the -
Correct Answers -AWWA standards

Approved backflow prevention assemblies must be designed to be - Correct Answers -
disassembled and repaired in line for all sizes

Check valves must be internally loaded and must be drip-tight - Correct Answers -in the
direction of flow with a minimum of 1 psi differential

The maximum allowable pressure loss through a 3/4" DCVA is - Correct Answers -10
psi

The maximum allowable pressure loss through a 3/4" RPBA is - Correct Answers -20
psi

The markings required to be on all approved backflow prevention assemblies include -
Correct Answers -make, model, direction of flow, & MWP

As part of an inspection of the assembly a BAT must determine - Correct Answers -if
the assembly is currently listed and approved for the orientation that it is installed

A cross-connection is defined as any actual or potential physical connection between a
public potable water system or the consumer's potable water system and any source of
non-potable liquid, solid, or gas that could the potable water supply by backflow -
Correct Answers -contaminate

The undesirable reversal of flow of water or other substances through a cross-
connection into the public water system or consumer's potable water system is - Correct
Answers -backflow

Backsiphonage backflow is defined as backflow due to a reduction in system pressure.
What else must be present for - Correct Answers -an opening to atmosphere

Which of the following may cause backpressure backflow? - Correct Answers -any of
the above (elevated piping, pumps, hot water tanks)

, A direct cross-connection is subject to - Correct Answers -both backsiphonage and
backpressure
A column of water exerts pressure at the bottom of the column due to the - Correct
Answers -weight of the water in the column

If the gauge pressure in a water pipe is negative, this means that exists - Correct
Answers -a vacuum

The BAT must complete a test report form acceptable to the local water purveyor -
Correct Answers -after every test of an approved backflow prevention assembly or
inspection of an approved air gap

The results of a test of an approved backflow prevention assembly must be reported to
the water purveyor on a form acceptable to - Correct Answers -the purveyor

An approved air gap is a physical separation between - Correct Answers -the end of the
potable water supply pipe and the overflow rim of the receiving vessel, a distance of at
least 2 times supply pipe diameter and never less than 1"

An approved air gap is acceptable as backflow protection for - Correct Answers -
Backpressure as well as Backsiphonage and both High and Low Health Hazard

An approved backflow prevention assembly is an RPBA, RPDA, DCVA, DCDA, PVBA,
or SVBA of make, model and size that is - Correct Answers -approved by the
Washington State DOH, ODW

Newly installed backflow assemblies have a initial test primarily due to: high rate of
failure at the time of the - Correct Answers -debris from within the supply piping

If a customer requires continuous water service it is recommended that - Correct
Answers -a parallel set of backflow assemblies appropriate for the degree of hazard be
installed

The shut off valves used on approved Backflow Prevention assemblies must always be
- Correct Answers -resilient seated

An approved backflow prevention assembly must be installed in such a manner that -
Correct Answers -it will not become flooded and with adequate space around the
assembly to facilitate testing and maintenance

An RPBA must not be installed where - Correct Answers -all of the above (water spilt
from the assembly will be objectionable, the assembly will become flooded, the
assembly is more than 60 inches above the floor or ground)

École, étude et sujet

Établissement
BACKFLOW
Cours
BACKFLOW

Infos sur le Document

Publié le
21 juillet 2025
Nombre de pages
7
Écrit en
2024/2025
Type
Examen
Contenu
Questions et réponses

Sujets

$12.99
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien


Document également disponible en groupe

Thumbnail
Package deal
BACKFLOW BUNDLED EXAM
-
42 2025
$ 514.08 Plus d'infos

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
Gordones22 Yala university
Voir profil
S'abonner Vous devez être connecté afin de pouvoir suivre les étudiants ou les formations
Vendu
498
Membre depuis
3 année
Nombre de followers
351
Documents
9499
Dernière vente
3 semaines de cela

4.1

108 revues

5
63
4
17
3
13
2
4
1
11

Documents populaires

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions