According to the IBC, the "blank" is to hire the special inspector. - 🧠
ANSWER ✔✔owner or owners agent. 2009 IBC Section 1704.1
According to the IBC, the "blank" is the responsible for the approval of a
person's qualifications to act as a special inspector. - 🧠 ANSWER ✔✔code
official. 2009 IBC, Section 1704.1
According to the IBC, discrepancy corrections are made known to the
building official by: - 🧠 ANSWER ✔✔final report. 2009 IBC, Section1704.1.2
When is the code official to be made aware of a discrepancy found during a
special inspection? - 🧠 ANSWER ✔✔If it is not corrected by the contractor.
2009 IBC, Section 1704.1.2
According to the Model Program for Special Inspection, the special
inspector is to document work that is nonconforming: - 🧠 ANSWER ✔✔In a
written report - Section II B 4 - Model Programs
COPYRIGHT©PROFFKERRYMARTIN 2025/2026. YEAR PUBLISHED 2025. COMPANY REGISTRATION NUMBER: 619652435. TERMS OF USE.
1
PRIVACY STATEMENT. ALL RIGHTS RESERVED
,According to the Model Program for Special Inspection, the special
inspector is to prepare written report of inspection: - 🧠 ANSWER ✔✔After
each inspection visit - Section II B 5 - Model Programs
According to the Model Program for Special Inspection, which of the
following items does not need to be included in each inspection report? - 🧠
ANSWER ✔✔Description of discussions with the contractor - Section B 5 -
Model Programs
According to the Specification for Structural Joints using high strength
bolts, the nominal diameter of standard bolt holes shall be how much larger
than the nominal bolt diameter? - 🧠 ANSWER ✔✔1/16 inch - Specification
for Structural Joints Table 3.1
Discrepancies in the work shall be brought to the immediate attention of the
"blank" for corrective action. - 🧠 ANSWER ✔✔the contractor - 2009 IBC,
Section 1704.1.2.
The special inspector shall furnish inspection reports to the "blank" and to
the "blank"? - 🧠 ANSWER ✔✔Building Official and Registered Design
professional
COPYRIGHT©PROFFKERRYMARTIN 2025/2026. YEAR PUBLISHED 2025. COMPANY REGISTRATION NUMBER: 619652435. TERMS OF USE.
2
PRIVACY STATEMENT. ALL RIGHTS RESERVED
, The special inspector shall provide continuos inspection of: - 🧠 ANSWER
✔✔Single-pass fillet welds greater than 5/16 inch in size - 2099 IBC, Table
1704.3, Item 5.3
The special inspections required by this code are not required where the
work is done on the premise of a? - 🧠 ANSWER ✔✔Approved fabricator -
2009 IBC, Section 1704.2.2
The special inspection of the steel fabrication process shall not be required
where the fabricator does not perform any? - 🧠 ANSWER ✔✔heating
operations - 2009 IBC, Section 1704.3, Exceptions # 1
According to the Specifications for Structural Steel Buildings, ASTM
Standard "blank" is to be used for the material test for steel sheets. - 🧠
ANSWER ✔✔A568 - Section A31, Specifications for Structural Steel
Buildings
According to the Specifications for Structural Steel Buildings, the "blank"
conducts the material tests for identification of the structural steel. - 🧠
ANSWER ✔✔Fabricator or Testing Laboratory - Section A31,
Specifications for Structural Steel Buildings.
COPYRIGHT©PROFFKERRYMARTIN 2025/2026. YEAR PUBLISHED 2025. COMPANY REGISTRATION NUMBER: 619652435. TERMS OF USE.
3