When modifying a electrical equipment you must stay in
compliance with OSHA codes. - ANSWER-True
Material safety data sheets serve to advise workers about
hazardous _____ present in the
area. - ANSWER-Chemicals
Why is an MSDS (material safety data sheet) relevant to the
security industry? - ANSWER-You or a colleague may be working
in labs or hospitals were dangerous chemicals are present
A bed shaker will: - ANSWER-Be limited to one bed at a time
Temporal 4 is associated with: - ANSWER-CO detectors
,2|Page
Audible devices in a public mode must be at least ___ decibels
about ambient sound. - ANSWER-15
An open collector output can directly power: - ANSWER-A relay
The Japanese horseradish smoke alarm is an example of which
sensory? - ANSWER-Olfactory
20 decibles are ___ times louder than 1 decibel. - ANSWER-100
According to the NFPA 72, the loudest an audible fire alarm
notification appliance can be
is ___ decibels. - ANSWER-110
Temporal 3 audible: - ANSWER-Will trigger a bed shaker
Audible requirements in sleeping rooms call for a minimum of ___
decibels at pillow
level. - ANSWER-75
,3|Page
A closed door between the sounder and mattress can cause a
loss of ___ decibels. - ANSWER-10 to 24
Holmes moved his alarm business from Boston to New York City
because - ANSWER-The people of Boston were skeptical about
having anything electrical in their homes
George Milliken's patent improved the burglar alarm by -
ANSWER-Having the first zoned alarm system
Three functions of an alarm system are ______, notification, and
control. - ANSWER-Detection
The best use of the duress alarm feature is ________. -
ANSWER-Sends a silent alarm when forced to disarm the alarm
system
60% of home debts resulted from fires in homes with _______. -
ANSWER-No working smoke alarms
, 4|Page
The four types of notifications are Audible, Visual, tactile, and
_______. - ANSWER-Olfactory
Which of these monitoring sites will most commonly be used to
monitor a university
alarm system? - ANSWER-Proprietary supervising station
One way in which signals are able to reach the appropriate
monitoring site is by ______. - ANSWER-All of the above
The most common hazard to humans in a building fire is
_______. - ANSWER-Smoke inhalation
An alarm system may be controlled using _____. - ANSWER-All
of the Above
A bigger gauge wire has less resistance and will carry more
current, which of the cables